Durability evaluation of a friction couple intended for implantological stabilization of complete dentures

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents the results of the study of the titanium implant–elastomeric membrane attachment, conducted from the point of view of potential utilization of the results in forecasting the durability of retention elements representing a new solution of dentures based on implants. The examination was carried out using a device designed by the author, which allowed the simulation of the process of inserting and removing dentures. Titanium counter specimens, simulating implants, were subjected to surface modification through their sandblasting with 350 ěm and 500 ěm abrasives, so as to diversify their roughness. The elastomeric membranes constituting a retention element of the attachment were made of a silicone material, Molloplast B. The influence of the number of cycles (one cycle meaning one insertion and removal of a denture) on the attachment’s retention force was studied. In order to better reflect the natural conditions, the device was equipped with a chamber which made it possible to perform the examination in an artificial saliva environment. The study has shown that the application of the polymer material Molloplast B for constructing the new type retention elements of dentures based on implants ensures practically constant values of the attachment's retention force in the required 6-month utilization period. After the time of denture usage, being eight times longer than originally assumed, the loss of retention force does not exceed 43% in any of the attachments investigated and the retention force values still allow the attachments to operate, although their effectiveness is partly reduced.
Rocznik
Strony
7--12
Opis fizyczny
Bibliogr. 19 poz., rys., tab.
Twórcy
autor
  • Department of Mechanics of Materials, Silesian University of Technology, Katowice, chladek@interia.pl
Bibliografia
  • [1] BOERRIGTER E.M., GEERTMAN M.E., VAN OORT R.P., BOUMA J., RAGHOEBAR G.M., VAN WAAS M.A.J., VAN HOF M.A., BOERING G., KALK W., Patient satisfaction with implant-retained mandibular overdentures. A comparison with new complete dentures not retained by implants multicentre randomized clinical trial, Journal of Oral and Maxillofacial Surgery, 1995, 133, 282–288.
  • [2] HEYDECKE G., KLEMETTI E., AWAD M., LUND J., FEINE J., Relationship between prosthodontic evaluation and patient ratings of mandibular conventional and implant prostheses, Int. J. Prosthodont., 2003, (16), 307–12.
  • [3] LEUNG T., HAAG B.M., Control of jaw closing forces: a comparison between implant-stabilised overdenture wearers and complete denture wearers, European Journal of Prosthodontics & Restorative Dentistry, 2000 Dec, 8 (4), 145–148.
  • [4] THOMASON J.M., LUND J.P., CHEHADE A., FEINE J.S., Patent satisfaction with mandibular implant overdentures and conventional dentures 6 months after delivery, Int. J. Prosthodont., 2003, (16), 467–73.
  • [5] CHLADEK G., CZĄSTKIEWICZ T., Implantologia – alternatywna metoda rekonstrukcji uzębienia, Praca Zdrowie Bezpieczeństwo, 2005, 3.
  • [6] CHLADEK W., MAJEWSKI S., MOL M., KRUKOWSKA J., Nowa koncepcja usprawnienia mechanizmu mocowania protez overdenture na filarach implantowanych w przednim odcinku wyrostka zębodołowego, Implantoprotetyka, 2003, 1.
  • [7] NAERT I., ALSAADI G., QUIRYNEN M., Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: A 10-year randomized clinical study, Int. J. Prosthodont., 2004, 17, 401–10.
  • [8] NÄRHI T.O., GEERTMAN M.E., HEVINGA M., ABDO H., KALK W., Changes in the edentulous maxilla in persons wearing implant-retained mandibular overdentures, The Journal of Prosthetic Dentistry, 2000, (84), 43–49.
  • [9] MACENTEE M.I., WALTON J.N., GLICK N., A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: three-year results, J. Prosthet. Dent., 2005, 93 (1), 28–37.
  • [10] ŻMUDZKI J., CHLADEK G., Ocena obciążenia strefy kotwienia filaru w aspekcie funkcjonowania implantoprotezy osiadającej, Materiały VI Konferencji „Biomateriały i Mechanika w Stomatologii”, Ustroń, 21–24 X 2004.
  • [11] CHLADEK G., ŻMUDZKI J., Ocena obciążenia tkanek miękkich w strefie kotwienia implantu stabilizującego całkowitą protezę osiadającą, Materiały XIII Seminarium Naukowego „Nowe Technologie i Materiały w Metalurgii i Inżynierii Materiałowej”, Katowice, 2005.
  • [12] Zgłoszenie patentowe 369859. Złącze cierne do implantologicznego systemu stabilizacji całkowitych dośluzowych protez zębowych, BUP 06-03-2006 05/2006.
  • [13] CHLADEK G., HADASIK E., Badania współczynnika tarcia złącza tytan–elastomer w obecności sztucznej śliny, VII Konferencja „Biomateriały i Mechanika w Stomatologii”, Ustroń, 2006.
  • [14] CHLADEK G., MARGIELEWICZ J., HADASIK E., Modelowanie współczynnika tarcia złącza tytan–elastomer, VII Konferencja „Biomateriały i Mechanika w Stomatologii”, Ustroń, 2006.
  • [15] CHLADEK G., DROZD B., Analiza zjawisk tarcia z złączu tytan–elastomer, Materiały III Sympozjum „Eksperyment i metody poznawcze w stomatologii”, Ustroń, 2007, Nowoczesny technik dentystyczny, wydanie specjalne, Katowice, 2007.
  • [16] CHLADEK G., MARGIELEWICZ J., HADASIK E., Numeryczne modelowanie współczynnika tarcia złącza tytan–elastomer, Materiały XV Seminarium Naukowego „Nowe technologie i materiały w metalurgii i inżynierii materiałowej”, Katowice, 18 maja 2007, 33–42.
  • [17] CHLADEK G., KRAWCZYK C., Badania lepkosprężystości próbek tytanowych na podstawie określenia czasu relaksacji naprężeń, Materiały III Sympozjum „Eksperyment i metody poznawcze w stomatologii”, Ustroń, 2007, Nowoczesny technik dentystyczny, wydanie specjalne, Katowice, 2007.
  • [18] CHLADEK G., MARGIELEWICZ J., CHLADEK W., Modelowanie numeryczne mechanizmu zakładania implantoprotezy typu „overdenture”, IV Krakowskie Warsztaty Inżynierii Medycznej, Kraków, 17–18 maj 2007, p. 9.
  • [19] CHLADEK W., HADASIK E., CHLADEK G., Influence of surfach modification on fiction coefficient of the titanium–elastomer couple, Acta of Bioengineering and Biomechanics, 2007, Vol. 9, No. 2.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPB9-0013-0002
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.