PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Functional outcome following the implantation of the modal/bipolar radial head endoprosthesis. Preliminary results

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Radial head fractures constitute 33% of all elbow fractures. In cases of unreconstructible fractures, the resection of the head was advocated. Radial head arthroplasty is an alternative way of the treatment. As the implantation could end up with complications, thus new and better designs are constantly looked for. One of such designs is modal/bipolar radial head endoprosthesis. The aim of this paper is to assess the functional outcome following the implantation of this endoprosthesis using movement analysis system. Seven patients participated in the study: 5 after implantation of endoprosthesis and 2 after surgical reconstruction of the radial head. The upper extremity movements with EMG were assessed during gait and pronation/supination movements with and without the external load. The functional abilities of patients with radial head endoprosthesis do not differ from those of the patients after the elbow reconstruction. This allows the patients normal, daily activity, with no restrictions and pain.
Rocznik
Strony
43--49
Opis fizyczny
Bibliogr. 13 poz., rys., wykr.
Twórcy
autor
autor
autor
  • The Children’s Memorial Health Institute, Department of Paediatric Rehabilitation, Warsaw
Bibliografia
  • [1] IKEDA M., OKA Y., Function after early radial head resection for fracture. A retrospective evaluation of 15 patients followed for 5–18 years, Acta Orthop. Scand., 2000, 71, 191–194.
  • [2] MORO J.K., WERIER J., MACDERMID J.C., PATTERSON S.D., KING G.J.W., Arthroplasty with a metal radial head for unreconstructible fractures of the radial head, J. Bone Jt. Surg., 2001, 83-A, 1201–1211
  • [3] KASTEN P., KRAFFT M., HESSELBACH J., WEINBERG A.-M., Kinematics of the ulna during pronation and supination in a cadaver study: implications for the elbow arthroplasty, Clin. Biomech., 2004, 19, 31–35
  • [4] BIRKEDAL J.P., DEAL D.N., RUCH D.S., Loss of flexion after radial head replacement, J. Shoulder Elbow Surg., 2004, 13, 208–213.
  • [5] ŚWIĘSZKOWSKI W., SKALSKI K., POMIANOWSKI S., KĘDZIOR K., The anatomic features of the radial head and their implication for prosthesis design, Clin. Biomech., 2001, 16, 880– 887.
  • [6] SKALSKI K.R., ŚWIĘSZKOWSKI W., POMIANOWSKI S., KĘDZIOR K., KOWALIK S., Radial head prosthesis with a mobile head, J. Shoulder Elbow Surg., 2004, 13, 78–85.
  • [7] TURCHIN D.C., BEATON D.E., RICHARDS R.R., Validity of observer-based aggregated scoring systems as descriptors of elbow functions, J. Elbow Should. Surg., 1998, 7, 305.
  • [8] KING G.J.W., RICHARDS R.R., ZUCKERMAN J.D., BLASIER R., DILLMAN C., FRIEDMAN R.J., GARTSMAN G.R., IANNOTTI I.P., MURNAHAN J.P., MOW V.C., WOO S.L.Y., A standardized method for assessment of elbow function, J. Elbow Should. Surg., 1999, 8, 351–354.
  • [9] MORTAZAVI S.M.J., ASADOLLAHI S., TAHRIRIAN M.A., Functional outcome following treatment of transolecranon fracture- dislocation of the elbow, Injury, Int. J. Care Injured, 2006, 37, 284–288.
  • [10] WILLIAMS J.R., CONBOY V.B., CARR A.J., Validation of a laboratory layout and VICON 370 marker set for the study of elbow function, J. Elbow Should. Surg., 1996, 5, 230.
  • [11] SIBELLA F., GALLI M., MOTTA F., CRIVELLINI M., Biomechanical model for upper limb movement analysis, Gait & Posture, 2002, Suppl. 1, 16, S189.
  • [12] POMIANOWSKI S., MICHALIK D., KORDASIEWICZ D., GRYGORUK R., KPS bipolar radial head prosthesis – clinical application, Proc. ISB 2006.
  • [13] PLASSCHAERT F., JONES K., FORWARD M., Normal threedimentional kinematic data for the arm during walking, Gait & Posture, 2006, 24S, SS217–S219.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPB1-0036-0006
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.