Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The paper presents application of the authors’ own method of investigating the secretion and elasticity of saliva as well as resilience of mucous membrane in evaluation of force holding the lower denture in the base. The object of research is a complete mucus lower denture cooperating with the base with a tooth-caving that is on the decline. Results of the tests of a horizontal force knocking the denture off the base were assumed as objective effectiveness evaluation criteria. Clinical investigation has been carried out in a group of 126 patients using diagnostic devices constructed according to the authors’ own conception. The elasticity of saliva was determined by measuring the length up to the break point where saliva loses elasticity, the sample volume being 55.26 mm3. The amount of saliva was determined on the basis of the area on which saliva remains and that is created by pressing the saliva with a force of 140 N by means of a 0.22 mm thick circular filter paper with a diameter of 8 mm. The filtering paper had earlier been put for 30 seconds on a mucous membrane in the area of molars. The resilience was determined on the basis of the penetrator’s cavity dented by a force of 1 N into the mucous membrane. Results obtained during the examination of a group of patients enabled an unambiguous numerical description of the characteristic features of oral cavity environment. A statistically significant influence of all investigated factors on the force necessary to knock the denture off the base has been determined. A significance hierarchy of the factors investigated as well as the ranges of variability in the parameters measured have been defined. The resilience of the mucous membrane has affected the denture knocking off force the most. It had a value of 0.4 mm up to 2.1 mm during an impact of a pointwise pressure of an average value of 0.99 mm. Then, the influence of the amount of the secreted saliva has been observed. The amount of the saliva gathered on the filter paper was expressed in terms of a “flood” area obtained after pressing the paper and amounted to 180 mm2 up to 660 mm2, with the average of 468.75 mm2. The least important factor was the elasticity determined by the break length of a saliva sample. The lengths of breakpoints measured were from 4.8 mm for saliva with a dominant serum secretion content up to 24.1 mm for saliva with a dominant mucus secretion content. The average value for the whole population examined was estimated at 14.19 mm.
Czasopismo
Rocznik
Tom
Strony
53--60
Opis fizyczny
Bibliogr. 20 poz., rys., wykr.
Twórcy
autor
autor
autor
- Silesian Technical University, Research Group for Medical Engineering, 40-019 Katowice, ul Krasińskiego 8, Poland
Bibliografia
- [1] BARDOW A., NYVAD B., NAUNTOFTE B., Relationships between medication intake, complaints of dry mouth, salivary flow rate and composition, and the rate of tooth demineralization in situ, Arch. Oral. Biol., 2001 May, 46(5), 413–423.
- [2] CHRISTERSSON C.E., LINDH L., ARNEBRANT T., Film-forming properties and viscosities of saliva substitutes and human whole saliva, Eur. J. Oral. Sci., 2000 Oct, 108(5), 418–425.
- [3] COMPAGNONI M.A., SOUZA R.F., LELES C.R., Kinesiographic study of complete denture movement related to mucosa displacement in edontulous patients, Pesqui Odontol Bras., 2003 Oct–Dec, 17(4), 356–361.
- [4] DAWES C., Physiological factors affecting salivary flow rate, oral sugar clearance, and the sensation of dry mouth in man, J. Dent. Res., 1987, 66(Spec. No.), 648–653.
- [5] HARA T., SATO T., NAKASHIMA K., MINAGI, Effect of occlusal pressure on the histopathological changes in denture supporting tissues, J. Oral. Rehabil., 1996 Jun, 23(6), 363–371.
- [6] HIRVIKANGAS M., POSTI J., MÄKILÄ E., Treatment of xerostomia through use of dentures containing reservoirs of saliva substitute, Proc. Finnish Dent. Sot., 1989, 85, 47–50.
- [7] KAWANO F., ASAOKA K., NAGAO K., MATSUMOTO N., Effect of viscoelastic deformation of soft tissue on stresses in the structures under complete denture, Dent. Mater. J., 1990 Jun, 9(1), 70–79.
- [8] KAWAZOE Y., HAMADA T., The role of saliva in retention of maxillary complete dentures, J. Prosthet. Dent., 1978 Aug, 40(2), 131–136.
- [9] MÁRTON K., BOROS I., FEJERDY P., MADLENA M., Evaluation of unstimulated flow rates of whole and palatal saliva in healthy patients wearing complete dentures and in patients with Sjögren’s syndrome, J. Prosthet. Dent., 2004, 91, 577– 581.
- [10] MIYAWAKI S., KATAYAMA A., TANIMOTO Y., ARAKI Y., FUJII A., YASHIRO K., TAKANO-YAMAMOTO T., Salivary flow rates during relaxing, clenching, and chewing-like movement with maxillary occlusal splints, Am. J. Orthod. Dentofacial. Orthop., 2004, 126, 367–370.
- [11] NAVAZESH M., CHRISTENSEN C.M., A comparison of whole mouth resting and stimulated salivary measurement procedures, J. Dent. Res., 1982, 61, 1158–1162.
- [12] NIEDERMEIER W.H., KRAMER R., Salivary secretion and denture retention, J. Prosthet. Dent., 1992 Feb, 67(2), 211–216.
- [13] OLSSON H., HENRICSSON V., SVENSSON A., AXELL T., Evaluation of in vitro properties of films of saliva substitutes in contact with different surfaces. A comparative study with instruments for measurements of friction and rheologic properties, Acta Odontol. Scand., 1995 Oct, 53(5), 334–338.
- [14] ORSTAVIK J.S., FLOYSTRAND F., Retention of complete maxillary dentures related to soft tissue function, Acta Odontol. Scand., 1984 Oct, 42(5), 313–320.
- [15] RANTONEN P.J., MEURMAN J.H., Viscosity of whole saliva, Acta Odontol. Scand., 1998 Aug, 56(4), 210–214.
- [16] WANG S.L., ZHAO Z.T., LI J., ZHU X.Z., DONG H., ZHANG Y.G., Investigation of the clinical value of total saliva flow rates, Arch. Oral. Biol., 1998 Jan, 43(1), 39–43.
- [17] WATANABE T., KOBAJASHI K., SUZUKI T., KUMAGAI H., ICHIKAWA K., KOBAJASHI K., KYU T., SATO I., NAGAO M., Development of a recording system for saliva pH with a complete denture by telemetry, Arch. Oral. Biol., 1997, Vol. 42, No. 3, 251–253.
- [18] WOLFF A., OFER S., RAVIN M., HELFT M., CARDASH H.S., The flow rate of whole and submandibular/sublingual gland saliva in patients receiving replecement complete dentures, J. Oral. Rehabil., 2004 Apr, 31(4), 340–343.
- [19] YEH C.K., JOHNSON D.A., DODDS M.W., SAKAI S., RUGH J.D., HATCH J.P., Association of salivary flow rates with maximal bite force, J. Dent. Res., 2000, 79, 1560–1565.
- [20] YURDUKORU B., TERZIOGLU H., YILMAZ T., Assessment of whole saliva flow rate in denture wearing patients, J. Oral. Rehabil., 2001 Jan, 28(1), 109–112.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPB1-0031-0031