PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Analysis of chosen strength factors of spine and spine-fixator set

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents chosen results of research on the lumbar-chest part of spine and the spine-fixator complex. Spines were gathered from cadavers. Both damaged and undamaged spines with and without fixator were investigated. Two types of fixator were used: a CD and a modified Zespol fixator (our idea) – marked as P. In the research, compression/distraction forces were applied. The analysis is based on the results of comparative calculation: load range, hysteresis loop area and neutral zone stiffness.
Słowa kluczowe
Rocznik
Strony
3--9
Opis fizyczny
Bibliogr. 14 poz. rys., tab., wykr.
Twórcy
  • Academy of Technology and Agriculture – Bydgoszcz, ul. ks. Kordeckiego 20, 85-225 Bydgoszcz, Poland
Bibliografia
  • [1] BĘDZIŃSKI R., WALL A., Wybrane zagadnienia biomechaniki kręgosłupa w aspekcie stabilizacji [in:] Uniwersalny system korekcyjno-stabilizujący DERO do operacyjnego leczenia kręgosłupa, D. Zarzycki (ed.), Zielona Góra, 1995.
  • [2] BĘDZIŃSKI R., Budowa modeli fizycznych elementów kręgosłupa lędźwiowego, Prace Naukowe Instytutu Konstrukcji i Eksploatacji Maszyn Politechniki Wrocławskiej, Wrocław, 1989.
  • [3] MALAWSKI S., Biomechanika kręgosłupa [in:] Spondyloortopedia, Part 1, S. Malawski (ed.), Centrum Metodyczne Kształcenia Podyplomowego, Warszawa, 1987.
  • [4] WILTSE L. et al., Classification of spondylolysis and spondylolisthesis, Clin. Orthop., 1976, 117.
  • [5] WILKE H.J., WENGER K., CLAES L.E., Testing criteria for spinal implants: recommendations for the standarization of in vitro stability testing of spinal implants, European Spine Journal, Springer-Verlag, 1998.
  • [6] WITTENBERG R.H., A biomechanical study of the fatigue characteristic of thoracolumbar fixation implants in a calf spine model, Spine, 1992, 17.
  • [7] ELLYIN F., KUJAWSKI D., Plastic Strain Energy, Fatigue, Journal of Pressure Vessel Technology, Trans. ASME, 1984, Vol. 106.
  • [8] SZALA J., Hipotezy sumowanie uszkodzeń zmęczeniowych, Wydawnictwa Uczelniane ATR, Bydgoszcz, 1998.
  • [9] PANJABI M.M., KRAG M., SUMMERS D., VIDEMAN T., Biomechanical time-tolerance of fresh cadaveric human spine specimens, J. Orthop. Res., 1985, 3, 292–300.
  • [10] WILKE H.J., JUNGKUNZ B., WENGER K., CLAES L.E., Spinal segment range of motion as a function of in vitro test conditions: effects of exposure period, accumulated cycles, angular- deformation rate, and moisture condition, Anat. Rec., 1998, 251, 15–19.
  • [11] ALBERT T.J., JONES A.M., BALDERSTON R.A., Spinal instrumentation. The spine, Saunders Co., 1993.
  • [12] GRANOWSKI R., RAMOTOWSKI W., BIELAWSKI J., Osteosynteza metodą ZESPOL. Teoria i praktyka, PZWL, Warszawa, 1988.
  • [13] WILKE H.J., ROHLMANN A., NELLER S., Is it Possible to Simulate Physiologic Loading Conditions by Applying Pure Moments? A Comparison of in vivo and in vitro Load Components in an Internal Fixator, Spine, 2001, Vol. 26, 636–642.
  • [14] ROHLMANN A., BERGMANN G., GRAICHEN F., WEBER U., Comparison of loads on internal spinal fixation devices measured in vitro and in vivo, Med. Eng. Phys., 1997, Vol. 19, No. 6, 539–546.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPB1-0031-0025
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.