PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Examinations on retention of overdentures with elastic frictional attachments

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Purpose: of this paper was to evaluate the effectiveness of the overdentures equipped with silicone elastic frictional attachments. Design/methodology/approach: The examinations of retention characteristics of traditional attachments, elastic frictional attachments and models of overdentures have been carried out using Zwick testing machine. Retention forces and work essential for separating the attachments have been determined as well. Next the force – displacement characteristics for overdenture model have been registered for two places where the force was applied and for three inclination angles of the line of application of force. Findings: The obtained results of laboratory examinations gave evidence of high effectiveness of elastic frictional attachments. Research limitations/implications: It has not been possible to register mechanical characteristics due to limitations of clinical conditions. Wide analysis of retention characteristics requires examinations carried out in laboratory conditions. Practical implications: Thorough analysis of force - displacement characteristics enables to understand better the mechanisms which are essential for the effectiveness of particular attachments. Applying such knowledge in practice helps to use more effectively the properties of silicone rubbers for making the elastic frictional attachments. Originality/value: The presented method of evaluating the effectiveness of attachments is based on determining retention work of the attachments and it allows to compare quite objectively even relatively different solutions. The so far used criterion of measuring vertical retention force makes it possible to compare only the solutions which are based on similar mechanical principles.
Rocznik
Strony
205--213
Opis fizyczny
Bibliogr. 15 poz., rys., tabl.
Twórcy
autor
autor
autor
  • Department of Technology of Materials, Silesian University of Technology, ul. Krasińskiego 8, 40-019 Katowice, Poland, chladek@interia.pl
Bibliografia
  • [1]W. Chladek, G. Chladek, T. Lipski, J. Margielewicz, J. Żmudzki, Biomechanical problems related to design of implantological overdenture stabilization system, Silesian University of Technology Publishing House, Gliwice, 2008 (in Polish).
  • [2]M.I. Macentee, J.N. Walton, N. Glick, A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year results, Journal of Prosthetic Dentistry 93 (2005) 28-37.
  • [3]J.N. Walton, S.C. Huizinga, C.C. Peck, Implant angulation: a measurement technique, implant overdenture maintenance, and the influence of surgical experience, International Journal of Prosthodontics 14 (2001) 523-530.
  • [4]G.K. Watson, A.G. Payne, D.G. Purton, W.M. Thomson, Mandibular overdentures: comparative evaluation of prosthodontic maintenance of three different implant systems during the first year of service, International Journal of Prosthodontics 15 (2002) 259-266.
  • [5]G. Chladek, Durability evaluation of a friction couple intended for implantological stabilization of complete dentures. Acta of Bioengineering and Biomechanics 10/3 (2008) 7-12.
  • [6]L. Breeding, D. Dixon, S. Schmitt, The effect of simulated function on the retention of bar-clip retained removable prostheses, The Journal of Prosthetic Dentistry 75/5 (1996) 570-573.
  • [7]J.N. Walton, N.D. Ruse, In vitro changes in clips and bars used to retain implant overdentures, Journal of Prosthetic Dentistry 74/5 (1995) 482-486.
  • [8]K. Wolf, K. Ludwig, H. Hartfil, M. Kern, Analysis of retention and wear of ball attachments, Quintessence International 40/5 (2009) 405-412.
  • [9]F. van Kampen, M. Cune, A. van der Bilt, F. Bosman, Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function, Clinical Oral Implants Research 14/6 (2003) 720-726.
  • [10]W. Sadig, A comparative in vitro study on the retention and stability of implant-supported overdentures, Quintessence International 40/4 (2009) 313-319.
  • [11]C.E. Besimo, A. Guarneri, In vitro retention force changes of prefabricated attachments for overdentures, Journal of Oral Rehabilitation 30/7 (2003) 671-678.
  • [12]D.M Botega, M.F. Mesquita, G.E Henriques, L.G. Vaz, Retention force and fatigue strength of overdenture attachment systems, Journal of Oral Rehabilitation 31 (2004) 884-889.
  • [13] O. Fromentin, C. Lassauzay, S. Abi Nader, J. Feine, R.F. de Albuquerque Jr., Testing the retention of attachments for implant overdentures - validation of an original force measurement system, Journal of Oral Rehabilitation 37 (2010) 54-62.
  • [14] C.A. Svetlize, E.F. Bodereau Jr., Comparative study of retentive anchor systems for overdentures, Quintessence International 35 (2004) 443-448.
  • [15] K.H. Chung, C.Y. Chung, D.R. Cagna, R.J. Cronin, Retention characteristics of attachment systems for implant overdentures, Journal of Prosthodontics 13 (2004) 221-226.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BOS2-0023-0047
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.