Purpose: The purpose of the paper is to describe Klystron pulse modulator of linear electron accelerator. Design/methodology/approach: TH-2158 klystron modulator experimental model is based on semiconductor switch HTS 181-160 FI (acceptable current load 1600 A, and voltage up to 18 kV). The results of test measurements carried out during modulator starting up period are presented in this work. TH-2158 klystron was used as a load. The klystron was connected to the second winding of the pulse HV transformer with 1:10 windings turn ratio. The examined modulator is equipped with safety shutdown circuitry for protection against current overload that may appear at IGBT switch in the case of short-circuiting happened in klystron and waveguide system. Findings: Linear electron accelerator type LAE 10/15 with electron energy 10 MeV and beam power up to 15 kW was designed and completed at Institute of Nuclear Chemistry and Technology. This accelerator was installed in facility for radiation sterilization single use medical devices, implants and tissue grafts. The standing wave accelerating section was selected. Microwave energy used for accelerating process is provided by klystron type TH-2158 working at frequency 2856 MHz. Practical implications: Described HV pulse modulator which designed and constructed for klystron TH-2158 was preliminary tested to evaluate the quality of the klystron HV and load current pulses and optimized selected component parameters. Obtained experimental results are better than those which were predicted by computer simulation method. Originality/value: Description of Klystron pulse modulator of linear electron accelerator.
Rocznik
Strony
775--778
Opis fizyczny
Bibliogr. 4 poz., rys., tabl.
Twórcy
autor
autor
autor
autor
  • Centre for Radiation Research and Technology, Institute of Nuclear Chemistry and Technology, ul. Dorodna 16, 03-195 Warsaw, Poland, dzwigal@orange.ichtj.waw.pl
Bibliografia
  • [1] Z. Dźwigalski, Z. Zimek, Klystron modulator for “elektronika 10/10” accelerator inct Annual Report 2004, Warsaw, 2005, 149-150.
  • [2] Z. Zimek, Z. Dzwigalski, S. Warchol, S. Bulka, K. R. B. Barc, Advanced System with High Energy Electron Beam for Research and Radiation Processing , Proceedings of the Eighth International Topical Meeting “Nuclear Applications and Utilization of Accelerators” ACCAPP`07, United States of America, 2007, 17.
  • [3] Z. Dźwigalski, Z. Zimek, Safety cut-out and trigger circuits of the th 2158 klystron modulator, inct Annual Report 2007, Warsaw, 2008, 149-151.
  • [4] Z. Zimek, Z. Dźwigalski, S. Warchol, K. Roman, S. Bułka, Examinations of th-2158 klystron modulator for the linear electron accelerator lae 10/15, inct Annual Report 2008, Warsaw, 2009, 158-160.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BOS2-0021-0090
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.