PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

Legionella prevention plan in water systems and its energetic consequences

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Sposób ochrony przed bakteriami legionella systemów wodnych i jego konsekwencje energetyczne
Języki publikacji
EN
Abstrakty
EN
Sporadic cases of Legionnaires' disease continue to occur. Undoubtedly, a considerable number of people have impaired defence against such bacterial infections, and the medical care has recently improved in such a considerable degree that the case-fatality ratio is very low nowadays. Nevertheless, the presence of Legionella pneumophila in hot and cold water systems operating in buildings is to be expected. The subject of the paper is the investigation of the Legionella hot water contamination as conducted in a cross-sectional survey in Kosice. The eradication measures based on a chemical, thermal or combined method, usually have a short-term effect (1-2 months), and therefore it is necessary to support them by a system of operating, technical and/or construction measures, the most significant of which is the adjustment of PHW distribution system, maintaining PHW temperature up to 55[degrees]C and daily preheating up to 60[degrees]C, as well as providing thermal disinfection twice a week at temperature [greather than or equal to] 70[degrees]C .
PL
Sporadyczne przypadki występowania choroby legionistów wciąż się zdarzają. Chociaż wiele ludzi ma upośledzoną zdolność obrony przed tymi bakteriami, to jednak wyższy standard opieki medycznej sprawił, że poziom zachorowań jest obecnie bardzo niski. Należy się jednak stale spodziewać obecności bakterii typu legionella w instalacjach wody ciepłej i zimnej. Przedmiotem artykułu są badania skażenia instalacji ciepłej wody bakteriami Legionella prowadzone na terenie Koszyc. Sposoby usuwania skażenia polegające na stosowaniu środków chemicznych, wysokiej temperatury lub łączone mają zwykle skutki krótkotrwałe (1-2 miesiące), dlatego też istotne jest opracowanie systemu stałego odkażania instalacji.
Rocznik
Strony
241--249
Opis fizyczny
Bibliogr. 10 poz.,Wykr., wz., rys.,
Twórcy
autor
autor
  • Institute of Building and Environmental Engineering, Civil Engineering Faculty, Technical University of Kosice, Slovakia
Bibliografia
  • [1] HC Information Resources Inc., www/hcinfo.com.
  • [2] Tobin J.O., Beare J., Dunnill M.S., Fisher-Hoch S., French M., Mitchell R.G., et al., Legionnaires’ disease in a transplant unit: isolation of the causative agent from shower baths, Lancet, 2, 1980, 118-21.
  • [3] Sabria M., Yu V.L., Hospital-acquired legionellosis: solutions for a preventable infection, Lancet Infect Dis, 2, 2002, 368-73.
  • [4] Pedro-Botet M.L., Sabria-Leal M., Sopena N., Manterola J.M., Torera J., Blavia R., et al., Role of immunosuppression in the evolution of Legionnaires’ disease, Clin Infect Dis, 26, 1998, 14-9.
  • [5] Straus W.L., Ploutve J.F., File T.M., Lipman H.B., Hackman B.H., et al., Risk factors for domestic acquisition of legionnaires disease, Arch Intern Med, 156, 1996, 1685-92.
  • [6] Col, Controlling Legionella in Domestic Hot water, Report of Armstromg International, Inc., Bussiness Briefing Hospital engineering and Facilities Management, 2003.
  • [7] Broadbent C., Legionella in Hot water Systems: Where we are?, Ecolibrum TM, April 2003.
  • [8] Vranayová Z., Košičanová D., Legionella infection risk from hot water systems, Selected Scientific Paper, Journal of Civil Engineering, Vol. 1, 2006, 57-68.
  • [9] EWGLI, European guidelines for control and prevention of travel associated Legionnaires’ disease, PHLS, London, United Kingdom.
  • [10] Miuetzner S., et al., Efficacy ot thermal treatment and cooper-silver ionization for controlling. Pneumophila in high-volume hot water plumbing systems in hospitals, Am. J. Infect. Control, 25, č. 6, 1997, 452-57.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BGPK-2826-0889
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.