PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Control of absorption chillers by insight: the characteristic equation

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Sterowanie wewnętrzne chłodni absorpcyjnych: równanie charakterystyczne
Języki publikacji
EN
Abstrakty
EN
Usually the control of absorption chillers is done via the temperature of the driving heat. It is set in dependence of the chilled water temperature. The temperature of the cooling water is almost constant and not being used for control. This method exhibits two drawbacks: there is optimization potenzial with regard to water consumption and fan power which is not addressed, and in solar cooling applications the temperature of the driving heat is not really free to be used for control. We will present a basic relation between the governing temperatures which can be used to control absorption chillers - especially with solar drive - and which may even be used to optimize water consumption and auxiliary power demand. Moreover, it allows for a diagnosis of deterioration or faulty behavior of the chiller. After derivation of the so-called characteristic equation experimental examples will be given.
PL
Sterowanie chłodni absorpcyjnych zwykle odbywa się poprzez kontrolę doprowadzanego ciepła, w zależności od temperatury wody chłodzącej. Temperatura wody chłodzącej zwykle jest niezmienna i nieprzydatna do sterowania. Zaprezentowano podstawowe zależności pomiędzy temperaturami sterowania użytecznymi do regulacji chłodni, szczególnie solarnych. Zależności mogą być wykorzystane do optymalizacji zużycia wody i zapotrzebowania na energię zewnętrzną. Co więcej mogą służyć do diagnozowania defektów pracy lub awarii schładzaczy. Rozważania wyników badań pozwoliły na sformułowanie równań charakterystycznych.
Rocznik
Strony
3--12
Opis fizyczny
Bibliogr. 8 poz.,Wz., wykr., il.,
Twórcy
autor
autor
autor
autor
  • Institut fur Energitechnik, Technische Universitat Berlin
Bibliografia
  • [1] Takada S.: Absorption Freezer, Japan Freezer Association, Japanese, 1982.
  • [2] Furukawa T. et al. : Study on Characteristic Temperatures of Absorption Heat Pumps, Proc. 20th Japan Heat Transfer Conf., June 1983, 508-510, Japanese.
  • [3] Furukawa T., Sonoda T.: Characteristics of H2O/LiBr Absorption Heat Pumps for the Temperature Change of External Fluids, XVII Internationaler Kongress für Kältetechnik, Wien, Austria, 24–29.08.1987.
  • [4] Riesch P., Scharfe J., Ziegler F., Völkl J., Alefeld G.: Part-Load Behavior of an Absorption Heat Transformer, Proceedings of the 3rd Int. Symposium on the Large Scale Applications of Heat Pumps, Oxford, England, 155-160, BHRA, The Fluid Engineering Centre, Cranfield, Bedford, 1987.
  • [5] Hellmann H.-M., Schweigler C., Ziegler F.: A simple method for modeling the operating characteristics of absorption chillers, Proc. of Eurotherm Seminar No. 59, Nancy-Ville, France, 6–7 July 1987, 219-226.
  • [6] Schweigler C., Ziegler F.: Single-effect/double-lift chiller: operational experience and prospect, Proc. of the 20th International Congress of Refrigeration, Sydney, 19–24 September 1999.
  • [7] Kühn A., Petersen S., Ziegler F., Kohlenbach P., Harm M., Schweigler C.: Operational results of a 10 kW absorption chiller for low-grade driving heat, International Sorption Heat Pump Conference, Denver, USA, 2005.
  • [8] Albers J., Ziegler F., Asdrubali F.: Investigation into the influence of the cooling water temperature on the operating conditions of thermosyphon generators, International Sorption Heat Pump Conference, Denver, USA, 2005.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BGPK-2578-9677
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.