The paper presents visualization of the degree of steel anchor adhesion. The paper describes two effective methods used in signal processing. The steel anchor is inserted in the rock mass by means of glue on the whole length of the glued surface. On many occasions as a result of the variable structure of rock mass, the insertion fails to include the whole length of glued surface. The determining of the quality of anchor fastening is important to estimate the construction endurance of sidewalk casing. Ultrasound imaging can improve the result by describing the strain and the state of local stress in the steel anchor. Reflection coefficients of impulse response were mapped by 2-dimensional view of the anchor cutting plane. The map can be used to estimate stress at the investigated points. The map can also be used to image insertion failures.
PL
W artykule przedstawiono problematykę związaną z wizualizacją stanu wklejenia kotwy stalowej w górotwór. Pręt stalowy stanowiący kotew zostaje wklejony w górotwór na całej długości lub tylko na końcu wpuszczonym w ścianę górotworu. W wielu przypadkach wklejenie to nie występuje na całej długości klejonej powierzchni kotwi. Niejednokrotnie w procesie eksploatacji kanał wklejenia kotwi ulega przesunięciu na skutek uskoków górotworu. W ekstremalnych przypadkach uskok może doprowadzić do ścięcia kotwi. Wszystkie uszkodzenia mają znaczący wpływ na wytrzymałość konstrukcji nośnej obudowy chodnika. Wyznaczenie jakości zamocowania kotwi utrudnia fakt, iż metoda musi być nieniszcząca i nieinwazyjna, a dostęp do niej jest tylko od strony wystającego końca z ściany chodnika. Metoda wizualizacji uszkodzenia kotwi oparta jest na analizie fali ultradźwiękowej rozchodzącej się w niej na skutek wymuszenia ukierunkowanym impulsem fali ultradźwiękowej.
Słowa kluczowe
Rocznik
Strony
3--14
Opis fizyczny
Bibliogr. 10 poz.,Rys., wz.,
Twórcy
autor
  • Instytut Metrologii Elektrycznej, Wydział Inżynierii Elektrycznej i Komputerowej, Politechnika Krakowska
Bibliografia
  • [1] Stergiopoulos S., Advanced Signal Processing Handbook - Theory and Implementation for Radar, Sonar, and Medical Imaging, CRC Press LLC, 2001.
  • [2] Gądek K., Linear Prediction Coding in Verification of the Quality of Steel Anchor Adhesion in Rock Mass; Proceedings of the IMEKO-TC7 Symposium "Measurement Science of the Information Era", Cracow, Poland, June 25-27, 2002, 182-185.
  • [3] Gunarathne G.P.P, Christidis K., Material Characterization in situ Using Ultrasound", Measurements IEEE Transaction on Instrumentation and Measurement, Vol. 51, No. 1, 2002, 368-374.
  • [4] Hidalgo R.M., Fernandez J.G., Rivera R.R., Larrondo H.A., Simple Adjustable Window Algorithm to Improve FFT Measurement, IEEE Transaction on Instrumentation and Measurement, Vol. 51, No. 1, 2002, 31-37.
  • [5] Semmlow J.L., Biosignal and Biomedical Image Processing MATLAB based Applications, Marcel Dekker, 2004.
  • [6] Misaridis T., Ultrasound Imaging Using Coded Signals, Technical University of Denmark, August 2001.
  • [7] Marwan Y., Digital Beam-Forming for High Resolution Wide Swath Real and Synthetic Aperture Radar, Dissertation, July 2004.
  • [8] Michailovich O., Dan A., Robust Estimation of Ultrasound Pulses Using Outlier-Resistant De-Noising, IEEE Transactions on Medical Imaging, Vol. 22, No. 3, March 2003.
  • [9] Gądek K., Measurement Analysis of the Degree of Steel Anchor Restraint in Rock Mass, PhD Thesis, Cracow University of Technology, Poland 2003 (in Polish).
  • [10] Gądek K., Identification of Anchor Damages in the Lining of Coal Mine Drifts Using Models of Impulse Responses, IV Symposium Dynamic Measurement, Gliwice, Poland 2002, 45-52 (in Polish).