PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Determination of ciprofloxacin In human gingival crevicular fluid by high-performance liquid chromatography

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
A simple and selective high-performance liquid chromatographic (HPLC) method has been developed for determination of ciprofloxacin in human gingival crevicular fluid (GCF). GCF samples were collected with paper strips. Ciprofloxacin was extracted from the pooled strips with me-thanol–water, 50:50 (v/v), and separated on a cartridge column (Radial-pak C18, 100 mm × 8 mm, 10 žm) with acetonitrile–sodium dihydrogen phos-phate, 2:8 (v/v), as mobile phase at a flow rate of 2 mL min-1. The effluent was monitored with a fluorescence detector at 280 nm (excitation) and 455 nm (emission). The retention times of ciprofloxacin and internal standard quinine sulphate were 4.55 and 13.25 min, respectively. The within-day and day-to-day precision were less than 9% for ciprofloxacin at 0.05, 0.1 and 0.4 µg mL-1 (n = 6), the within-day and day-to-day accuracy values were in the range 96.33–102.67% for ciprofloxacin at the concentrations given above and the detection limit corresponding to a signal-to-noise ratio of 3:1 was 3 ng mL-1. This method was suitable and selective for determi-nation of ciprofloxacin levels in human GCF.
Słowa kluczowe
Rocznik
Tom
Strony
306--314
Opis fizyczny
Bibliogr. 13 poz., rys., tab.
Twórcy
autor
  • Department of Pharmacology, Faculty of Medicine, Hacettepe University, Ankara, Turkey
autor
  • Department of Periodontology, Faculty of Dentistry, Hacettepe University, Ankara, Turkey
autor
  • Department of Periodontology, Faculty of Dentistry, Hacettepe University, Ankara, Turkey
autor
  • Department of Pharmacology, Faculty of Medicine, Hacettepe University, Ankara, Turkey
Bibliografia
  • [1] T.J. Babinchak, Clin. Infect. Dis., 21, 1517 (1995)
  • [2] J.W. Kleinfelder, R.F. Mueller, and D.E. Lange, J. Periodontol., 71, 1561 (2000)
  • [3] J.M. Gordon, C.B. Walker, J.M. Goodson, and S.S. Socransky, Antimicrob. Agent Chemother., 17, 193 (1980)
  • [4] P.B. Robertson, M. Lantz, P.T. Maruchka, K.S. Komman, C.L. Trummel, and S.C. Holt, J. Periodontol. Res., 17, 275 (1982)
  • [5] L. Eisenberg R. Suchow, R.S. Coles, and M.J. Deasy, Clin. Pren. Dent., 13, 28 (1991)
  • [6] J. Wolfson and D.C. Hooper, Antimicrob. Agent Chemother., 28, 581 (1985)
  • [7] N.E. Basci, A. Bozkurt, D. Kalaycý, and S.O. Kayaalp, J. Pharm. Biomed. Anal., 14, 353 (1996)
  • [8] L.K. Jim, N. el-Sayed, and K.I. Al-Khamis, J. Clin. Pharm. Ther., 17, 111 (1992)
  • [9] A.C. Mehta, S. Hart-Davies, and E.A. Kay, J. Clin. Pharm. Ther., 17, 117 (1992)
  • [10] G. Carlucci, J. Chromatogr., 812, 343 (1998)
  • [11] T.B. Conway, F.M. Beck, and J.D. Walters, J. Periodontol., 71, 1448 (2000)
  • [12] H.J. Rudin, H.F. Overdiek, and K.H. Rateitschack, Helv. Odontol. Acta., 14, 21 (1970)
  • [13] S. Braggio, R.J. Barnaby, P. Grossi, and M. Cugola, J. Pharm. Biomed Anal., 14, 375 (1996)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT3-0028-0089
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.