PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Multiresidue determination of diazinon and ethion in pistachio nuts by use of matrix solid phase dispersion with a lanthanum silicate co-column and gas chromatography

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Diazinon and ethion in pistachio nuts have been analyzed by use of matrix solid-phase dispersion (MSPD) followed by gas chromatography with nitrogen-phosphorus detection (GC-NPD). The efficiency of different adsorbents (C18, cyano, phenyl, and amino) for MSPD of pistachio nuts was compared. Lanthanum silicate ion-exchanger was used as co-column material. Recoveries for C18-MSPD co-column lanthanum silicate were 95% for ethion and 94% for diazinon with relative standard deviations of 7-13% in the concentration range 0.5-4 mg kg-1. The limits of detection were 0.02 mg kg-1 for ethion and 0.035 mg kg-1 for diazinon; these were lower than the maximum residue limits (MRL) established by WHO/FAO. Thin-layer chromatography was performed on lanthanum silicate and lanthanum tungstate ion exchangers to ensure the pesticide residues were present in the final MSPD extract.
Słowa kluczowe
Rocznik
Tom
Strony
208--214
Opis fizyczny
Bibliogr. 11 poz., rys., tab.
Twórcy
autor
  • Department of Chemistry, Science and Research Campus, P.O. Box: 14515/775, Islamic Azad University, Tehran, Iran
  • Department of Chemistry, Science and Research Campus, P.O. Box: 14515/775, Islamic Azad University, Tehran, Iran
autor
  • Instrumental Analysis Laboratory, Plant Paste and Design Research Institute, Ministry of Agriculture Research Organization, Tehran, Iran
  • 2Instrumental Analysis Laboratory, Plant Paste and Design Research Institute, Ministry of Agriculture Research Organization, Tehran, Iran
Bibliografia
  • [1] E.M. Thurman and M.S. Mills, Solid Phase Extraction, Principles and Practice, Wiley, New York,1998
  • [2] S.A. Barker, A.R. Long, and C.R. Short, J. Chromatogr., 475, 363 (1989)
  • [3] S.A. Barker, J. Chromatogr. A, 880, 63 (2000)
  • [4] S.W. Husain, M.G. Maragheh, and S.H. Rasheedzad, J. Radioanal. Nucl. Chem., 84, 239 (1984)
  • [5] M.G. Maragheh, S.W. Husain, A.R. Khanchi, and S.J. Ahmadi, Sep. Sci. Technol., 34, 219 (1999)
  • [6] V. Ghoulipour and S.W. Husain, Anal. Sci., 16, 1079 (2000)
  • [7] S.W. Husain, M.G. Maragheh, and M. Anbia, J. Appl. Radiat. Isot., 44, 745 (1993)
  • [8] S.W. Husain , S.H. Rasheedzad, J.L. Manzoori, and Y. Jabbari, Sep. Sci. Technol., 17, 935 (1982)
  • [9] E. Stahl, Thin Layer Chromatography, A Laboratory Handbook, Springer, Berlin, 1969
  • [10] J.C. Miller and J.N Miller, Statistics for Analytical Chemistry, Ellis Horwood, Chichester, 1988, pp. 102–115
  • [11] Codex Alimentarius Commission (WHO/FAO), Codex maximum Residue Limits for Pesticides, Vol. 2, Rome, 1993
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT3-0026-0058
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.