PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
Tytuł artykułu

Optimization and validation of a high-performance liquid chromatographic method for determination of alpha- and gamma-tocopherol in rat plasma and erythrocytes

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
An HPLC method for determination of α- and γ-tocopherol in rat blood has been optimized and validated. The optimum means of separation and analysis of tocopherol homologs were selected on the basis of proce-dures found in the literature; documentary evidence is presented which shows precision and accuracy were satisfactory. Spectrofluorimetric detec-tion was performed after separation on a Separon SGX NH2 analytical column with n-hexane-2-propanol, 97:3, as mobile phase; racemic tocol was used as internal standard. A suspension of erythrocytes was saponified and tocopherols were extracted in the presence of BHT, ascorbic acid, and pyrogallol. Plasma samples were extracted without saponification but with antioxidant protection. Validation revealed that intra-day and inter-day RSD in plasma were 0.78% and 4.15%, respectively, for α-tocopherol and 4.03% and 13.155%, respectively, for γ-tocopherol. Intra-day RSD for erythrocytes were 3.75% and 2. 89% for α-tocopherol and γ-tocopherol, respectively. Absolute percentage recovery from plasma and erythrocytes was 99.8 ± 7.5 and 94 ± 9.0, respectively, for α-tocopherol and 100.2 ± 7.5 and 96.9 ± 7.8, respectively, for γ-tocopherol. Limits of detection in plasma and erythrocytes were 0.005 and 0.002 μg mL-1, respectively, for α-tocopherol and 0.002 and 0.0015 μg mL-1, respectively, for γ-tocopherol. Limits of quantification in plasma and erythrocytes were 0.015 and 0.006 μg mL-1, respectively, for α-tocopherol and 0.006 and 0.0045 μg mL-1, respectively, for γ-toco-pherol.
Słowa kluczowe
Rocznik
Tom
Strony
185--195
Opis fizyczny
Bibliogr. 15 poz., rys., tab.
Twórcy
autor
  • Department of Toxicology, Faculty of Pharmacy, Medical College, Jagiellonian University, Medyczna str. 9, 30-688 Kraków, Poland
autor
  • Department of Toxicology, Faculty of Pharmacy, Medical College, Jagiellonian University, Medyczna str. 9, 30-688 Kraków, Poland
autor
  • Department of Toxicology, Faculty of Pharmacy, Medical College, Jagiellonian University, Medyczna str. 9, 30-688 Kraków, Poland
autor
  • Department of Toxicology, Faculty of Pharmacy, Medical College, Jagiellonian University, Medyczna str. 9, 30-688 Kraków, Poland
Bibliografia
  • [1] M. Mino, O. Kasugai, and T. Shimizu, Lipids, 20, 488 (1985)
  • [2] L. Zimmermann, N. Pages, H. Antebi, A. Hafi, C. Boudene, and L.G. Alcindor, Biol. Trace. Elem. Res., 38, 311 (1993)
  • [3] H. Antebi, N. Pages, L. Zimmermann, C. Bourcier, and B. Flechet, Ann. Nutr. Metab., 39, 63 (1995)
  • [4] K. Yanagawa, H. Takeda, T. Matsumiya, and M. Takasaki, Find. Exp. Clin. Pharmacol., 21, 195 (1999)
  • [5] E. Simon, J-L. Paul, V. Atger, A. Simon, and N. Moatti, Free Radic. Biol. Med., 28, 815 (2000)
  • [6] Q. Jiang, S. Christen, M.K. Shigenaga, and B.N. Ames, Am. J. Clin. Nutr., 74, 714 (2001)
  • [7] F.J. Ruperez, D. Martin, E. Herrera, and C. Barbas, J. Chromatogr. A, 935, 45 (2001)
  • [8] A. Sobczak, B. Skop, and B. Kula, J. Chromatogr. B, 730, 265 (1999)
  • [9] C. Kiyose, H. Saito, T. Ueda, and O. Igarashi, J. Nutr. Sci. Vitaminol., 47, 102 (2001)
  • [10] B. Nilsson, B. Johansson, L. Jansson, and L. Holmberg, J. Chromatogr., 145, 169 (1978)
  • [11] T. Julianto, K.H. Yuen, and A.M. Noor, J. Chromatogr. B, 732, 227 (1999)
  • [12] G.T. Vatassery, W.E. Smith, and H.T. Quach, Anal. Biochem., 214, 426 ( 1993)
  • [13] M.J. Gonzalez – Corbella, N. Lloberas – Blanch, A.I. Castellote – Bargallo, M.C. Lopez – Sabater, and M. Rivero – Urgell, J. Chromatogr. B, 660, 395 (1994)
  • [14] H. Kanazawa, C. Miyata, Y. Nagata, S. Urano, and Y. Matsushima, Chem. Pharm. Bull., 48, 1462 (2000)
  • [15] H. Ihara, H. Ishigaki, Y. Shino, N. Hashizume, M. Takase, J. Nagao, and Y. Sumiyama, J. Nutr. Sci. Vitaminol., 46, 257 (2000)
Typ dokumentu