Tytuł artykułu
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
Drylab G software has been used to optimize the reversed-phase HPLC separation of taxoids and co-extracted substances from yew. Two preliminary runs based on a linear gradient from 5 to 100% acetonitrile (ACN) in 20 or 60 min were shown to be satisfactory for optimization of resolution. The optimization experiments were performed on a purified extract fortified with taxoid standards. The identity and purity of the peaks were verified by use of photodiode-array detection. Agreement between simulated and experimental data was good. The optimized chromatographic system can be used for quantitative analysis of paclitaxel, cephalomannine, and 10-deacetylbaccatin in yew extracts.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
211--218
Opis fizyczny
Bibliogr. 26 poz., rys., tab.
Twórcy
autor
- Department of Pharmacognosy, Medical University, Peowiaków 12, 20-007 Lublin, Poland
autor
- Department of Inorganic and Analytical Chemistry, Medical University, Staszica 6, 20-081 Lublin, Poland
autor
- Department of Pharmacognosy, Medical University, Peowiaków 12, 20-007 Lublin, Poland
Bibliografia
- [1] M. Suffness, in: G. I. Georg, T. T. Chen, I. Ojima, and D. M. Vyas (Eds), Taxane Anticancer Agents: Basic Science and Current Status, American Chemical Society, Washington, DC, 1995, p. 1
- [2] M. Suffness and M. E. Wall, in: M. Suffness (Ed.), Taxol: Science and Applications, CRC Press, Boca Raton, FL, 1995, p. 3
- [3] K. Głowniak, T. Wawrzynowicz, M. Hajnos, and T. Mroczek, J. Planar Chromatogr., 12, 328 (1999)
- [4] K. Głowniak and T. Mroczek, J. Liq. Chromatogr., 22, 2483 (1999)
- [5] G. Theodoridis, C. F. de Jong, G. Laskaris, and R. Verpoorte, Chromatographia, 47, 1 (1998)
- [6] V. Verstraeten and D. de Keukeleire, Phytother. Res., 10, 147 (1996)
- [7] M. Ł. Hajnos, K. Głowniak, and A. Zobel, Phytomedicine, 8, 139 (2001)
- [8] M. Ł. Hajnos, K. Głowniak, M. Waksmundzka-Hajnos, and P. Kogut, J. Planar Chromatogr., 14, 119 (2001)
- [9] H. Engelhardt, B. Dreyer, and H. Schmidt, Chromatographia, 16, 11 (1982)
- [10] P. J. Schoenmakers, Optimization of Chromatographic Selectivity, Elsevier, Amsterdam, 1986
- [11] L. R Snyder and J. W. Dolan, Chem. Anal. (Warsaw), 43, 495 (1998)
- [12] L. R. Snyder, J. L. Glajch, and J. J. Kirkland, Practical HPLC Method Development, 2nd edn, Wiley–Interscience, NY, 1997
- [13] J. W. Dolan, D. C. Lommen, and L. R. Snyder, J. Chromatogr., 485, 91 (1989)
- [14] L. R. Snyder and J. W. Dolan, Drylab G Instruction Manual, LC Resources, Lafayette, CA, 1987
- [15] E. Soczewiński and C. A. Wachtmeister, J. Chromatogr., 7, 311 (1962)
- [16] T. H. Dzido and A. Sory, Chem. Anal. (Warsaw), 41, 113 (1996)
- [17] T. H. Dzido and H. D. Smolarz, J. Chromatogr. A, 679, 59 (1994)
- [18] T. H. Dzido, B. Polak, M. Wojcińska, and W. Gołkiewicz, Chem. Anal. (Warsaw), 45, 353 (2000)
- [19] W. Markowski, L. K. Czapińska, A. J. Józefczyk, and K. Głowniak, J. Liq. Chromatogr., 21, 2497 (1998)
- [20] W. Markowski, T. H. Dzido, and E. Soczewiński, J. Chromatogr., 523, 81 (1990)
- [21] T. H. Dzido, E. Soczewiński, and J. Gudej, J. Chromatogr., 550, 71 (1991)
- [22] W. Markowski and L. K. Czapińska, Chem. Anal. (Warsaw), 42, 353 (1997)
- [23] M. A. Hawrył, E. Soczewiński, and T. H. Dzido, J. Chromatogr. A., 886, 75 (2000)
- [24] M. Ł. Hajnos, K. Głowniak, M. Waksmundzka-Hajnos, and S. Piasecka, Chromatographia, in press
- [25] G. Theodoridis, G. Laskaris, C. F. de Jong, A. J. P. Hofte, and R. Verpoorte, J. Chromatogr. A., 802, 297 (1998)
- [26] S. Bala, G. C. Uniyal, S. K. Chattopadhyay, V. Tripathi, K. V. Sashidhara, M. Kulshrestha, R. P. Sharma, S. P. Jain, A. K. Kukreja, and S. Kumar, J. Chromatogr. A., 858, 239 (1999)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT3-0026-0038