Non-linear properties of cardiomyocyte membranes are poorly understood. We model a cell membrane using the Beeler-Reuter model with the Drouhard-Roberge modification (the BRDR model). Simulations are performed using AC voltage test excitation of 1 or 100kHz frequency and 1 or 10mV RMS. Values of currents flowing through the cell membrane are considered to be the response. The BRDR response is presented at the fundamental frequency and at its second and third harmonics. The response is mainly contributed to by the time-independent potassium current (iK1) during resting membrane potential. The level of currents varies strongly during the period of action potential. However, the linear response from the membrane capacitance is relatively high. The second and third harmonics of the 1kHz/10mV probing voltage carry some information about the action potential. In particular, it may be used to investigate the process of repolarization and its disorders.
Rocznik
Strony
423--437
Opis fizyczny
Bibliogr. 12 poz., rys., tab.
Twórcy
autor
  • Department of Biomedical Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-952 Gdansk, Poland
  • Department of Biomedical Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-952 Gdansk, Poland
autor
  • Department of Computer System Architecture, Gdansk University of Technology, Narutowicza 11/12, 80-952 Gdansk, Poland
Bibliografia
  • [1] Cinca J, Warren M, Carreno A, Tresanchez M, Armadans L, Gomez P and Soler-Soler J 1997 Circulation 96 (9) 3079
  • [2] Drazner M H, Thompson B, Rosenberg P B, Kaiser P A, Boehrer J D, Baldwin B J, Dries D L and Yancy C W 2002 Am. J. Cardiol. 89 (8) 993
  • [3] Hodgkin A L and Huxley A F 1952 J. Physiol. 117 (4) 500
  • [4] Beeler G W and Reuter H 1977 J. Physiol. 268 (1) 177
  • [5] Drouhard J P and Roberge F A 1987 Comput. Biomed. Res. 20 (4) 333
  • [6] Skouibine K B, Trayanova N A and Moore P K 1999 IEEE Trans. Biomed. Eng. 46 (7) 769
  • [7] Luo C H and Rudy Y 1994 Circ. Res. 74 (6) 1071
  • [8] Luo C H and Rudy Y 1994 Circ. Res. 74 (6) 1097
  • [9] Luo C H and Rudy Y 1991 Circ. Res. 68 (6) 1501
  • [10] Richardot A and McAdams E T 2002 IEEE Trans. Med. Imaging 21 (6) 604
  • [11] Huiskamp G 1998 IEEE Trans. Biomed. Eng. 45 (7) 847
  • [12] Muzikant A L and Henriquez C S 1998 IEEE Trans. Biomed. Eng. 45 (4) 449