PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

A new acoustic emission descriptor for modelled sources of partial discharges

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Partial discharges (PD) generated by differently modelled PD sources have been studied by the acoustic emission (AE) method. The results obtained were compared with the measured apparent electric charge values. Acoustic images of the PD phenomena were created by recorded waveforms, phase diagrams, frequency characteristics and calculated amplitude distribution diagrams. Basing on the amplitude distributions, a new AE descriptor --- the ADP descriptor (Amplitude Distribution of Power of AE signal descriptor) was evaluated. The ADP descriptor distinguishes the physical processes connected with the PD. For the described measuring situations, the calculated values of the ADP descriptor show a good correlation of the ADP descriptor values with the value of the apparent electric charge.
Słowa kluczowe
Rocznik
Strony
65--77
Opis fizyczny
Bibliogr. 10 poz., rys., tab., wykr.
Twórcy
autor
  • Institute of Physics, Technical University of Silesia, 44-100 Gliwice, ul. B. Krzywoustego 2, Poland
autor
  • Institute of Electrical Power and Control Systems, Technical University of Silesia, 44-100 Gliwice, ul. B. Krzywoustego 2, Poland
autor
  • Institute of Physics, Technical University of Silesia, 44-100 Gliwice, ul. B. Krzywoustego 2, Poland
Bibliografia
  • [1] S. Cesari, C. Hantouche, T. Muraoka and B. Pouliquen, PD measurements as a diagnostic tool, ELECTRA, No. 181 December 1998, 25-51.
  • [2] B. Florkowska, Partial discharge in high voltage insulating systems - analyses of mechanisms, forms and images [in Polish], IPPT PAN, Warszawa 1997.
  • [3] M. Florkowski, PD image recognition using neural network for high voltage insulation system, Monographies No 45, ISSN 087-6631, Kraków 1996.
  • [4] AE - sources, methods and applications [in Polish], IPPT PAN, Warszawa 1994.
  • [5] J. Skubis, Investigations of the insulation of electro power systems by means of acoustic emission, IPPT PAN, Warszawa 1993.
  • [6] Proceedings of VII Symposium Problems of High Voltage Insulating System Exploitation EUI99 [in Polish], Zakopane 1999.
  • [7] F. Witos, Z. Opilski, Z. Gacek and K. Maniewski, Comparative investigations on PD generated in a model source, Second Int. Conf. on Dielectric & Insulation, High Tatras 2000, 126-131.
  • [8] T. Takashima, Y. Higo and S. Nunomura, Determination of the duration of transient phenomena by frequency domain analysis of AE, Philosophical Mag., 49, 221-227 (1984).
  • [9] I. Malecki, F. Witos and A. Opilski, AE source parameters in coal samples, Acustica, 79, 112-116 (1993).
  • [10] T. Boczar, AE spectra generated by PD within oil insulation [in Polish], Politechnika Opolska, Seria Studia i Monografie, 114 (2000).