The paper presents an innovative and improved method for doubled calibration of an eddy-current conductometer. Implementation of the proposed method makes it possible to achieve independence of the instrument indications on surface condition of the examined parts. The calibrating function is determined on-line when the measurements are in progress on the basis of parameters that are assigned to the contact probe coil and calculated with use of general mathematic equations. The calculated correction parameter can be considered as a measure of the surface roughness. Application of the modification as described in this paper can contribute to efficiency improvement of operational examinations for components made of non-ferrous materials during their lifetime.
PL
Zaproponowano oryginalną, ulepszoną metodę podwójnego skalowania konduktometru wiroprądowego. Realizując tę metodę można uzyskać niezależność wskazań przyrządu od stanu powierzchni badanych elementów. Funkcja skalująca konduktometr jest wyznaczana dynamicznie w czasie trwania pomiaru na podstawie parametrów przypisanych eksperymentalnie sondzie-cewce stykowej oraz uniwersalnych równań matematycznych. Obliczona poprawka może być traktowana jako miara chropowatości powierzchni. Stosując opisaną modyfikację można znacznie usprawnić badania eksploatacyjne elementów wykonanych z metali nieżelaznych.
Rocznik
Tom
Strony
35--40
Opis fizyczny
Bibliogr. 12 poz.
Twórcy
autor
  • Institute of Engineering Processes Automation and Integrated Manufacturing Systems, Silesian University of Technology in Gliwice 35, Konarskiego St., 44-100 Gliwice, Poland, andrzej.buchacz@polsl.pl
Bibliografia
  • 1. Dodd C V, Deeds W E, Luquire J W. Integral solutions to some eddy current problems. International Journal of Nondestructive Testing 1969; 1: 29–90.
  • 2. Dziczkowski L. A definition of eddy current penetration depth useful for flaw detection and conductivity measurement. Journal of Applied Mathematics and Mechanics 2008; 8(1): 10205-10206.
  • 3. Dziczkowski L. A mathematic model to determine optimum conditions for measurements of material conductance by means of the eddy current method applicable to large structures. Mašinostroenie i Technosfera XXI weka. Sbornik Trudow XV Meždunarodnoj Naučno-techničeskoj Konferencji. Donieck 2009; 4: 69-73.
  • 4. Dziczkowski L, Dziczkowska M. Effect of inaccurate setting for the exciting field frequency onto results of conductance measurements with use of the eddy current method. Avtomatizacja: Problemy, Idei, Rešenija, Materialy Meždunarodnoj Naučnotechničeskoj Konferencji. Sevastopol: Vidavnictvo SevNTU, 2010; 2: 3-5.
  • 5. Dziczkowski L. Effect of eddy current frequency on measuring properties of devices used in non- destructive measurements of non-ferromagnetic metal plates. Archives of Materials Science and Engineering 2008; 32(2): 77-84.
  • 6. Dziczkowski L. Errors in conductance measurement of materials that are used for construction of thick plates. Mašinostroenie i Technosfera XXI weka. Sbornik Trudow XV Meždunarodnoj Naučno-techničeskoj Konferencji. Donieck 2009; 4: 66-69.
  • 7. Dziczkowski L. Surface roughness and eddy current. 6th International Conference Mechanic Systems and Materials. MSM Opole – Poland 5 – 8 July 2010: 58 –59.
  • 8. Geirinhas Ramos H M, Postolache O, Corrêa Alegria F, Lopes Ribeiro A. Using the Skin Effect to Estimate Cracks Depths in Mettalic Structures. International Instrumentation and Measurement Technology Conference. I2MTC Singapore 5-7 May 2009: 1-6.
  • 9. Jasiński W, Zawada P. The investigation of discreteness in material of catalytic pipes by the eddy current method. Eksploatacja i Niezawodnosc - Maintenance and Reliability 2003; 2: 28-30.
  • 10. PN-87/M-04251. Struktura geometryczna powierzchni. Chropowatość powierzchni. Wartości liczbowe parametrów. Norma Polska 30.06.1987.
  • 11. Simankowa L. Mathematical presentation of impedance variation of a coil cause by the measured object. TESLA electronics 1971; 4: 112-117.
  • 12. Theodoulidis T, Kriezis E. Series expansions in eddy current nondestrutive evaluation models. Journal of Materials Technology 2005; 161(1-2): 343-347.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT1-0039-0061
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.