Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The subject of the paper is the comparison of four complementary methods of the rotor loss estimation in a PM SM, supplied by a PWM voltage source. An ANSYS based finite element model produces values of W, the magnetic energy stored, and P, the rotor losses. On analytical level the machine is represented by a parallel two elements equivalent circuit for each voltage harmonic. Its parameters are estimated using P and W values. Finally, the eddy current losses representation in the ANSYS code is verified for magnets under study by direct losses measurements. The calculation results are compared with some measured values resulting from analysis and harmonic decomposition of the machine total losses.
Słowa kluczowe
Rocznik
Tom
Strony
113--116
Opis fizyczny
Bibliogr. 4 poz.
Twórcy
autor
autor
autor
autor
- Supelec Departement Energie, 91192 Gif sur Yvette, France, jean-claude.vannier@supelec.fr
Bibliografia
- 1. Abu Sharkh S.M., Harris M.R. and Taghizadeh Irenji N.: Calculation of rotor eddy current loss in high speed PM Alternators. IEE Int Conf. Electrical Machines and Drives, 1997, Conference Publication n° 444, pp.170-174.
- 2. Zhu Z. Q., Howe D., Chan C.C.: Improved Analytical Model for Predicting the Magnetic Field Distribution in Brushless Permanent-Magnet Machines. IEEE Trans. Magn. Vol. 18 n°1, Jan 2002, pp. 229-238.
- 3. Wang Z.Y.: Analyse et mesures de pertes dans le rotor d.une machine synchrone a aimants permanents pour en optimiser la structure. These de doctorat Paris XI-Supélec, 2005.
- 4. Wang Z.Y., Vannier J.C., Randria A., Kaczmarek R.: Improvement of permanent magnet synchronous motor performances reducing the rotor losses. All Electric Ship AES 2005, Versailles oct. 2005.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT1-0028-0015