Abstrakty
In the article the results of an analysis of the performance of a unit operated with incomplete sliding-pressure and with full sliding-pressure adjusted each time to a specific load are shown. The article also presents the gain obtained from the use of full sliding-pressure resulting from the reduction of thermodynamic loss in the system and the reduction of the unit's own needs. The measurements of the condensation-heating turbo set operated with incomplete sliding-pressure was used in the analysis.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
44--48
Opis fizyczny
Bibliogr. 3 poz.
Twórcy
autor
autor
autor
autor
- Institute of Power Engineering and Turbomachinery The Silesian University of Technology, ul. Konarskiego nr 18, 44-100 Gliwice, Poland, krzysztof.nawrat@polsl.pl
Bibliografia
- [1] Perycz S.: Gas and Steam Turbines, Wydawnictwo PAN Wrocław 1992 (in Polish).
- [2] Energopomiar.: A Report on Thermal Guarantee Measurements. Record Nş: 249/ZC/2005 (in Polish).
- [3] Kosman G., Łukowicz H., Kosman W.: An Analysis of Unit Losses Determined by Direct Balance Calculations. 10th International Conference of Boiler Technology 2006, Prace IMiUE Politechniki Śląskiej, 2006 (in Polish).