Utilization of a neutral wire filter inductor in a three-leg four-wire active power filter

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Three-leg active power filter topology is the cost effective solution implementing a four-wire active power filter but it has some disadvantages compared to four-leg topology. The lack of a neutral wire filter inductor results in larger filter losses and therefore the efficiency of the topology is impaired. The neutral wire filter inductor is typically used with the four-leg four-wire active power filter topology and significantly reduces switching frequency current ripple. In this paper the suitability of a neutral wire filter inductor for the three-leg topology is studied. The performance of three-leg topology with a neutral wire filter inductor is studied through computer simulations and laboratory tests. The results indicate that the use of the neutral wire filter inductor clearly improves the performance of three-leg topology.
Twórcy
  • Tampere University of Technology, Institute of Power Electronics, Finland
autor
  • Tampere University of Technology, Institute of Power Electronics, Finland
autor
  • Tampere University of Technology, Institute of Power Electronics, Finland
Bibliografia
  • 1. Fang-Zhuo, Yue-Wang and Zhao’an-Wang: The configuration of main circuit and control strategy for active power filter in three-phase four-wire systems. Power Electronics Specialists Conference — PESC 2001, 17th—2lst June 2001, Vancouver, Canada, Vol. 3, pp. 1615-1618.
  • 2. Holmes D.G. and Lipo T.A.: Pulse Width Modulation for Power Converters — Principles and Practice. Publisher: Wiley — Interscience, 2003, pp. 226-241.
  • 3. Kim S. and Enjeti P. N .: Control strategies for active power filter in three-phase four-wire systems. Applied Power Electronics Conference and Exposition -— APEC 2000, 6th-10th February 2000, New Orleans, Louisiana, USA, Vol. 1, pp. 420-426.
  • 4. Pettersson S., Salo M. and Tuusa H.:Performance comparison of the voltage source four-wire active power filter topologies. International Power Electronics Conference — IPEC Niigata 2005, 4th - 8th April 2005, Niigata, Japan, pp. 701-708.
  • 5. Quinn C . A. and Mohan N. : Active filtering of harmonic currents in three-phase four-wire systems with three-phase and single-phase non-linear loads. Applied Power Electronics Conference and Exposition — APEC’92, 23rd—27th February 1992, Boston, Massachusetts, USA, pp. 829-836.
  • 6. Routimo M., Salo M. and Tuusa H.: A control delay compensation method for voltage source active power filter. 9th European Power Quality Conference —- PCIM 2003, 20th—22nd May 2003, Niimberg, Germany, pp. 93-97.
  • 7. Salo M. and Tuusa H. : A novel open-loop control method for a current-source active power filter. IEEE Transactions on Industrial Electronics, 50, 2, pp. 313-321, April 2003.
  • 8. Vas P. : Electrical Machines and Drives -— A Space- Vector Theory Approach. Publisher: Clarendon Press — Oxford, 1992, Chapter 2.