PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Voltage source power line conditioners

Identyfikatory
Warianty tytułu
PL
Napięciowe kondycjonery energii
Języki publikacji
EN
Abstrakty
EN
The paper presents a different way for a power quality conditioning. The different way means parallel connection of the sinusoidal voltage source with the network, therefore it is possible to "isolate" load from source and vice versa. Described conditioner makes possible to get: i) sinusoidal source current; ii) reactive power compensation; iii) load voltage stabilization; iv) balanced source in conditions of the unbalanced load (in 3-phase networks). As a sinusoidal voltage source in 3-phase network, the four level cascade based Voltage Source Converter (VSC) has been used. The effectiveness of the Voltage Source Power Line Conditioners (VPLC) is carefully outlined, while the systems general performance and flexibility are intensively investigated. To confirm results of the theoretical analysis some experimental results were presented.
PL
W artykule opisano inny sposób poprawy jakości energii. Inny sposób oznacza tutaj równolegle połączenie z siecią źródła napięcia sinusoidalnego w wyniku czego możliwa jest "izolacja" obciążenia od sieci i vice versa. Opisany kondycjoner umożliwia uzyskanie: i) sinusoidalnego prądu sieci; ii) kompensacji mocy biernej; iii) stabilizacji napięcia na obciążeniu; iv) symetryzacji sieci w przypadku niesymetrycznego obciążenia (w sieciach 3-fa-zowych). Jako źródło napięcia sinusoidalnego, w sieciach 3-fazowych, wykorzystano kaskadowy czteropoziomowy falownik VSI. W artykule zbadano skuteczność Napięciowego Kondycjonera Energii (VPLC) oraz opisano jego podstawowe właściwości. Wyniki analizy teoretycznej zostały poparte wynikami badań eksperymentalnych.
Twórcy
  • Maritime University of Gdynia
autor
  • University of Zielona Góra
autor
  • University of Zielona Góra
autor
  • University of Zielona Góra
Bibliografia
  • 1. Strzelecki R., Supronowicz H.: Power factor in AC supply systems and improvement methods, Publishing House of the Technical University of Warsaw, Warsaw 2000.
  • 2. Rusiński J, Sozański K, Strzelecki f..:Kompensatory aktywne w sieciach prqdu przemiennego, Conf. Proc. "Jakosc energii elektrycznej w sieciach elektroenergetycznych w Polsce", pp.129-138, Poznań, Poland 2000.
  • 3. Strzelecki R., Rusiriski J., Benysek G.: Voltage source power quality conditioner, Conf, Proc. of EPNC 2002, pp. 179-182, Leuvcn, Belgian, 2002.
  • 4. Slrzelecki R., Benysek G., Rusiński J., Kot E.: Analysis of DC Link Capacitor Voltage Balance in Multilevel Active Power Filters, Conf. I'roc. of EPE'OI, CD-ROM, Graz, Austria, 2001.
  • 5. Benysek G., Kot E.: Analysis of DC link capacitor voltage balance in cascade parallel ac.live power fillers, Conf. Proc. of PEDC'01, pp. 120-126, Zielona G6ra, Poland, 2001.
  • 6. Fujita H., Watanabe Y., Akagi H.: Control and analysis of a unified power flow controller, IEEE Trans. Power Electronics, vol.14, no.6, pp.1021-1027, 1999.
  • 7. Peng F., Akagi H., Nabae H.: Compensation characteristics of ihe combined system of shunt passive and series active filters, lEEfc Trans, on Industry Applications, vol.29, no.l, pp.144-15, 1993.
  • 8. Gyugyi L, Kalyan K.. S., Schauder C. D.: The interline power flow controller concept: a new approach to power flow management in transmission systems, IEEE Transactions on Power Delivery, vol.14, no.3, pp.1115-1122, 1999.
  • 9.Strzelecki R., Benysek G., Fedyczak Z., Bojarski J.: Interline power flow controller - probabilistic approach", Conf. Proc. of PESC'02, Vol. 2, pp. 1037-1042, Cairns, Australia, 2002.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT1-0015-0018
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.