PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

IEC flickermeter used in power system monitoring. Part 1, Comparative tests

Identyfikatory
Warianty tytułu
PL
Miernik wahań napięcia IEC do pomiarów w systemie elektroenergetycznym. Cz. 1, Testy porównawcze
Języki publikacji
EN
Abstrakty
EN
The test has been carried out for the flickermeters being designed according to the requirements and provisions of IEC 61000-4-15 standard. Objective of the test is the assessment of flickermeters suitability for measuring voltage fluctuations of various waveforms, occurring in power supply systems. The paper presents results of the measurements carried out at one of Polish steelworks, at the electric steelworks supply bus-bars. Duration of the measurement was seven days. Ten various flickermeters, their conformity to IEC 61000-4-15 standard requirements declared in specifications, have been used for these measurements. The second part of this paper presents results of laboratory Bests performed for five selected flickermeters. The investigation has been carried out according to UIE WG 2 "Power Quality" specified tests for calibration and verification of a flickermeter [11]. Because of the limitations of instruments used during the investigation not every test has been performed in accordance with the original proposition. The other tests, as being unrealizable, were performed for the flickermter model developed in MATLAB - SIMULINK environt [10].
PL
Testy przeprowadzone zostały dla mierników migotania swiatła skonstruowanych w oparciu o przepisy normy IEC 61000-4-15. Ich celem było sprawdzenie przydatności przyrządów do pomiarów różnorodnych przypadków wahań napięcia występujących w systemach zasilania. W artykule przedstawiono wyniki tygodniowych pomiarów wykonanych na szynach elektrostalowni w jednej z polskich hut, za pomocą dziesięciu mierników migotania, które zgodnie z specyfikacją techniczną ich producentów spełniają wymagania normy IEC 61000-4-15. W części drugiej niniejszego artykułu przedstawiono wyniki testów laboratoryjnych pięciu wybranych mierników migotania przeprowadzonych zgodnie z procedurą zapropo-nowaną przez UIE WG 2 "Power Quality" [11]. Nie wszyst-kie testy zostały przeprowadzone zgodnie z oryginalną pro-pozycją, ze względu na techniczne ograniczenia aparatury stosowanej podczas badań. Pozostałe testy, niemożliwe do realizacji przeprowadzono dla modelu miernika migotania opracowanego w środowisku MATLAB - SIMULENK [10].
Rocznik
Strony
5--21
Opis fizyczny
Bibliogr. 11 poz., rys., wykr.
Twórcy
autor
  • Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, University of Science and Technology, Cracow.
autor
  • Institute of Electrical Orive and Industrial Equipment ControI of University of Science and Technology - AGH
autor
  • University of Science and Technology - AGH, Department of Measurement and Instrumentation, Al. Mickiewicza 30., 30-059 Kraków
autor
  • Maritime University at Gdynia
autor
  • Doctorate student at the Faculty of Electrical Engineering, Automatics, Computer Science and Electronics at the AGH-UST, Power Distribution Company - Cracow
Bibliografia
  • 1. Bień A., HanzeIka Z., Hartman M. et aI. Voltage fluctuations m easurem ent - experiment in the industrial environment. Electrical Power Quality and Utilisation, 7, 2, 200 I.
  • 3. Bień A., Hanzelka Z., Hartman M., Piekarz M ., Sz osek M.· Comparative test oj jlickermeters X International Conference on Harmonie and Quality of Power. Rio de Janerio 2002.
  • 4. Guide to quality oj electrical supply Jor industrial installations Part 5: UIEPQ-9713, 1999.
  • 5. Hashad M., Hartman M., Hanzelka Z., Bień A.: The hypothesis Jor the wrong measurements results obtained during the jlickermeter comparative test. 6th International Conf. Electrical Power Quality and Utilisation, Sept. 19-21, 200 I, Cracow.
  • 6. lEC 61000-4-15: Flickermeter - Functional and design specifications. 2002.
  • 7. Kowalski Z., HanzeIka Z.: Limits of voltage fluctualians. (in polish). EPQU 1,3, 1997.
  • 8. Matlab, Simulink, user guide.
  • 9. Mombauer W.: EMV - Messung von Spannungs-Schwankungen und F/ickern mit dem lEC-F/ickermeter. VDE Verlag (109) 2000.
  • 10. Rogoz M.· The lEC flickermeter model. Elektrotechnika i Elektronika. 2003 Zeszyt I. T.22.
  • 11. Szlosek M., Piekarz M., Hanzelka Z., Bień A. and others: Comparative tests oj flickermeters. 17th CI-RED - International Conference & Exhibition on Electricity Distribution I, Barcelona, 12-15 May 2003.
  • 12. Test Protocol - lEC F/ickermeter Used in Power System Monitoring. Prepared by UlE WG2 "Power Quality" 2001
Uwagi
Błędna numeracja bibliografii - brakuje poz. 2.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT1-0005-0010