Residential cold and hot potable water-meters are the most popular measurement instruments (MI) of legal metrology regulation used for custody transfer. The performance of utility water meters of different design (single jet vane wheel meter, concentric multi-jet vane wheel meter, volumetric meter with ring piston) with nominal flow rate 1.5 m3/h has been investigated when installed downstream from five different gasket diameters - 15.0 mm, 14.2 mm, 12.7mm, 10.0 mm and 8.7 mm. Effects of turning of the meter around the pipe axis investigated too. The largest positive percentage errors up to 25% are re- ported for the 8.7 mm gaskets for single-jet vane wheel meter while volumetric meters are not sensitive to gasket bore reduction. Turning around the pipe axis procure negative additional percentage error which value at lower flow range reaches up to -20%...-30% for some type of meters. Tested volumetric meters are the less sensitive to considered installation effects in comparison with vane meters.
Słowa kluczowe
Rocznik
Tom
Strony
283--287
Opis fizyczny
Bibliogr. 7 poz., rys., wykr.
Twórcy
autor
autor
  • Lithuanian Energy Institute, Kaunas, Lithuania
Bibliografia
  • [1] Law on Drinking Water Supply and Waste Water Management of the Republic of Lithuania on 13 July 2006. Official Gazette: 27.07.2006, No. 82-3260 (in Lithuanian).
  • [2] ISO 4064-1:1993(E) Measurement of water flow in closed conduits — Meters for cold potable water — Part 1: Specifications.
  • [3] Technical Construction Regulation STR 2.07.01:2003, Water-Supply and Waste Water Treatment. Building Services. Outdoor Engineering Networks. Official Gazette: 2003, No. 83-3804 (in Lithuanian).
  • [4] Briliute I., Bonckus A., Zygmantas G.: Influence of installation effects on the performance of residential water-meters. The 7th International Conference „Environmental Engineering”, May 22-23 2008, Vilnius, Selected papers, Vol. II, P. 785-792.
  • [5] OIML R 49-2:2004(E) Water meters intended for the metering of cold potable water — Part 2: Test methods.
  • [6] ISO 4064-3:2005(E) Measurement of water flow in fully charged closed conduits — Meters for cold potable water and hot water — Part 3: Test methods and equipment.