Vlianie pul'sacij potoka na poteri gaza v promyslennosti i gazoraspredelitel'nih setah

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
EN
The influence of gas flow pulsation on the gas losses in industry and gas distribution networks
Konferencja
Efektywność energetyczna 2009 : Kraków, 21-23 września 2009 : międzynarodowa konferencja naukowo-techniczna
Języki publikacji
RU
Abstrakty
EN
Flow pulsation in the turbine gas meters cause dynamic error, amounting to tens of percent. So far, the problem has been studied only for pulsations by rarely encountered in practice, simple laws. To calculate the meters' response and dynamic error at pulsing by any arbitrary law the new method has been developed and implemented. It is based on the concept of meters' inertia time constant as the only characteristic of transitional processes of rotation. For the first time the information on the turbine meter behavior under sign alternating pulsation conditions, when the instantaneous flow periodically changes direction on the op-posed one has been obtained. The results has been analyzed and generalized. and compared with the experimental ones obtained with a specially delivered facility. Gas pulsations parameters and the dynamic error have been researched in one of the thermal power plants. The measures have been proposed to reduce pulsing and errors to the acceptable values to avoid vibrations.
Rocznik
Tom
Strony
263--268
Opis fizyczny
Bibliogr. 6 poz., wykr.
Twórcy
autor
  • Litovskij Energeticeskij Institut, g. Kaunas, Litva
Bibliografia
  • [1] ISO/TR 3313:1998(E) Measurement of fluid flow in closed conduits — Guidelines on the effects of flow pulsations on flow-measurement instruments.
  • [2] W.F.Z. Lee, M.J. Kirik, B. Millington: Gas turbine flow meter measurement in pulsating flow. Eng. Power, Trans. ASME, 1975, October, pp 531-539.
  • [3] K.N. Atkinson: A software tool to calculate the overregistration error of a turbine meter in pulsating flow. Flow Meas. Instrum., 1992, 3, No 3, pp 167-172.
  • [4] R.J. McKee: Pulsation effects on single- and two rotor turbine meters. Flow Meas. Instrum., 1992, 3, No 3, pp 151-166.
  • [5] R. Cheesewright., K.N. Atkinson, C. Clark, G.J.P. Horst, R.C. Motoram, J. Viljeer: Field tests of correction procedures for turbine flowmeters in pulsate flows. Flow Meas. Instr., 1996, 7, No 1, pp 7-17.
  • [6] J. Tonkonogij, A. Stankevicius: Investigation of transient processes in turbine gas meters. ISSN 1392- 1223 Measurements, 2007, No. 1, 39, pp. 29-36.