Determination of the influence of calibration sphere parameters on the results of articulating probe head qualification

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The qualification of probe heads before the measurements performed with their usage is now a standard procedure. It is used for correction of probe head’s and measuring tip systematic errors. The calibration sphere, which is used for this process, should have adequately small form errors. However, it is not always possible to use a highly accurate spheres and it is a common practice to use a sphere that was provided by the manufacturer of the CMM for a long time. This is why, the authors have tried to answer the question about the impact of the calibration sphere inaccuracies on the results of probe head qualification process.
Twórcy
autor
  • Laboratory of Coordinate Metrology, Cracow University of Technology, al. Jana Pawła II 37, 31-864 Cracow, Poland
autor
  • Laboratory of Coordinate Metrology, Cracow University of Technology, al. Jana Pawła II 37, 31-864 Cracow, Poland
autor
  • Laboratory of Coordinate Metrology, Cracow University of Technology, al. Jana Pawła II 37, 31-864 Cracow, Poland
  • Laboratory of Coordinate Metrology, Cracow University of Technology, al. Jana Pawła II 37, 31-864 Cracow, Poland
  • Laboratory of Coordinate Metrology, Cracow University of Technology, al. Jana Pawła II 37, 31-864 Cracow, Poland
Bibliografia
  • 1. Cuesta E., Alvarez B., Sanchez-Lasheras F., Gonzalez-Madruga D.: A statistical approach to prediction of the CMM drift behaviour using a calibrated mechanical artefact, Metrology and Measurement Systems, 22 (3), 2015, 417–428.
  • 2. Gruza M., Gąska A., Gąska P., Harmatys W., Sładek J.: Analiza wpływu trybu pracy pięcioosiowego systemu współrzędnościowego na dokładność pomiaru. Mechanik, 2016, 11, 1708 - 1709.
  • 3. Harmatys W., Gąska P., Gąska A., Gruza M., Sładek J., Determination of temperature impact on CMM residual kinematic errors distribution, Advances in Science and Technology Research Journal, 9 (26), 2015, 113-117.
  • 4. Hasselman T., Lloyd G.: A top-down approach to calibration, validation, uncertainty quantification and predictive accuracy assessment, Computer Methods in Applied Mechanics and Engineering 197 (29–32), 2008, 2596–2606.
  • 5. Hocken R. J., Pereira P. H.: Coordinate Measuring Machines and Systems, Second Edition. CRC Press, USA, 2012.
  • 6. Ratajczyk E., Woźniak A.: Współrzędnościowe systemy pomiarowe. Oficyna Wydawnicza Politechniki Warszawskiej, Polska, Warszawa 2016.
  • 7. Sładek, J: Coordinate Metrology: Accuracy of Systems and Measurements. Springer. Germany, Berlin 2016.
  • 8. Weckenmann A., Estler T., Peggs G., McMurtry D.: Probing Systems in Dimensional Metrology. CIRP Annals Manufacturing Technology, 2004, 53(2), 657-684.
  • 9. Zavvar M, Ramezani F, A method based on fuzz system for assessing the reliability of software based aspects, Advances in Science and Technology Research Journal, 9 (27), 2015, 143-148.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-adfbe95a-6402-4dcd-9dd0-ebaa8b77f400
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.