Shooting training is associated with exposure to a considerable amount of unique noise. We wanted to evaluate noise exposure during such training. Our observations especially apply to professional sport shooters, but they are also valid for shooting coaches/instructors. We collected acoustic signals in 10-, 25- and 50-m as well as open-air shooting ranges. The recorded material was analysed with orthogonal, adaptive parameterization by Shur. The mean duration of a single acoustic signal was 250–800 ms with the C-weighted sound peak pressure level of 138.2–165.2 dB. Shooters may be exposed to as many as 600–1350 acoustic impulses during a training unit. The actual load for the hearing organ of a professional shooter or a shooting coach is ~200 000 acoustic stimuli in a year-long training macrocycle. Orthogonal, adaptive parameterization by Shur makes safe scheduling of shooters’ training possible.
Słowa kluczowe
Wydawca
Rocznik
Tom
Strony
69--77
Opis fizyczny
Bibliogr. 37 poz., rys., wykr.
Twórcy
autor
- Department of Health Promotion, University School of Physical Education in Wrocław, Poland
autor
- Department of Sports Medicine and Nutrition, University School of Physical Education in Wrocław, Poland
autor
- Department of Sports Medicine and Nutrition, University School of Physical Education in Wrocław, Poland
Bibliografia
- 1.Kryter KD. Effects of nosocusis, and industrial and gun noise on hearing of U.S. adults. J Acoust Soc Am. 1991;90(6):3196–201.
- 2.Price GR, Kim HN, Lim DJ, Dunn D. Hazard from weapons impulses: histological and electrophysiological evidence. J Acoust Soc Am. 1989;85(3):1245–54.
- 3.Pekkarinen J, Iki M, Starck J, Pyykko I. Hearing loss risk from exposure to shooting impulses in workers exposed to occupational noise. Br J Audiol. 1993;27(3):175–82.
- 4.Price GR. Predicting mechanical damage to the organ of Corti. Hear Res. 2007;226(1–2):5–13.
- 5.Thompson IL. Gun noise, its nature and effects. Australian Shooters Journal. 1992;20:87–9.
- 6.Rylander R, Lundquist B. Annoyance caused by noise from heavy weapon shooting ranges. J Sound Vibrat. 1996;192(1):199–206.
- 7.Counter SA, Borg E, Olofsson A. Ototraumatic effects of computer simulated magnetic coil impulse noise: analysis of mechanisms. Acta Otolaryngol. 1993;113(6):699–705.
- 8.Hamernik RP, Ahroon WA, Hsueh KD. The energy spectrum of an impulse: its relation to hearing loss. J Acoust Soc Am. 1991;90(1):197–204.
- 9.Henselman LW, Henderson D, Subramaniam M, Sallustio V. The effect of “conditioning” exposures on hearing loss from impulse noise. Hear Res. 1994;78(1):1–10.
- 10.Starck J, Toppila E, Pyykko I. Impulse noise and risk criteria. Noise Health. 2003;5(20):63–73.
- 11.Paakkonen R, Lehtomaki K. Protection efficiency of hearing protectors against military noise from handheld weapons and vehicles. Noise Health. 2005;7(26):11–20.
- 12.Tambs K, Hoffman HJ, Borchgrevink HM, Holmen J, Engdahl B. Hearing loss induced by occupational and impulse noise: results on threshold shifts by frequencies, age and gender from the Nord-Trondelag Hearing Loss Study. Int J Audiol. 2006;45(5):309–17.
- 13.Price GR. Validation of the auditory hazard assessment algorithm for the human with impulse noise data. J Acoust Soc Am. 2007;122(5):2786–802.
- 14.Chan PC, Ho KH, Kan KK, Stuhmiller JH, Mayorga MA. Evaluation of impulse noise criteria using human volunteer data. J Acoust Soc Am. 2001;110(4):1967–75.
- 15.Rice CG. Human response effects of impulse noise. J Sound Vibrat. 1996;190(3):525–43.
- 16.Lusk SL. Noise exposures. Effects on hearing and prevention of noise induced hearing loss. AAOHN J. 1997;45(8):397–408; quiz 409–10.
- 17.McNamee R, Burgess G, Dippnall WM, Cherry N. Predictive validity of a retrospective measure of noise exposure. Occup Environ Med. 2006;63(12):808–12.
- 18.Prince MM, Gilbert SJ, Smith RJ, Stayner LT. Evaluation of the risk of noiseinduced hearing loss among unscreened male industrial workers. J Acoust Soc Am. 2003;113(2):871–80.
- 19.Daniell WE, Swan SS, McDaniel MM, Camp JE, Cohen MA, Stebbins JG. Noise exposure and hearing loss prevention programmes after 20 years of regulations in the United States. Occup Environ Med. 2006;63(5):343–51.
- 20.Turkkahraman S, Gok U, Karlidag T, Keles E, Ozturk A. Findings of standard and high-frequency audiometry in workers exposed to occupational noise for long durations. Kulak Burun Bogaz Ihtis Derg. 2003;10(4):137–42. In Turkish.
- 21.Fausti SA, Wilmington DJ, Helt PV, Helt WJ, Konrad-Martin D. Hearing health and care: the need for improved hearing loss prevention and hearing conservation practices. J Rehabil Res Dev. 2005;42(4 Suppl 2):45–62.
- 22.Dewilde P, Dym H. Shur recursions, error formulas and convergence of rational estimators for stationary stochastic processes. IEEE Transon IT. 1981(27):446–61.
- 23.Dewilde P. A course on the algebraic Shur and Nevanlinna-Pick interpolation problems. In: Deprettere A, editor. Algorithms and parallel VLSI architectures. London, UK: Elsevier; 1991. p. 13–70.
- 24.Lee DTL, Morf M, Friedlander B. Recursive least-squares ladder estimation algorithms. IEEE Trans on CAS. 1981(28): 467–81.
- 25.Ferber-Viart C, Soulier N, Dubreuil C, Duclaux R. Cochleovestibular afferent pathways of trapezius muscle responses to clicks in human. Acta Otolaryngol. 1998;118(1):6–10.
- 26.Zwislocki J. Analysis of middle ear function. Part I. Input impedance. J Acoust Soc Am 1996;34:1514–23.
- 27.Zheng XY, McFadden SL, Ding DL, Henderson D. Cochlear de-efferentation and impulse noise-induced acoustic trauma in the chinchilla. Hear Res. 2000;144(1–2):187–95.
- 28.Onusko E. Tympanometry. Am Fam Physician. 2004;70(9):1713–20.
- 29.Uchida Y, Nomura H, Itoh A, Nakashima T, Ando F, Niino N, Shimokata H. The effects of age on hearing and middle ear function. J Epidemiol. 2000;10(1 Suppl):S26–32.
- 30.Henderson D, Subramaniam M, Gratton MA, Saunders SS. Impact noise: the importance of level, duration, and repetition rate. J Acoust Soc Am. 1991;89(3):1350–7.
- 31.Paakkonen R, Lehtomaki K, Savolainen S, Myllyniemi J, Hamalainen E. Noise attenuation of hearing protectors against heavy weapon noise. Mil Med. 2000;165(9):678–82.
- 32.Ylikoski M, Pekkarinen JO, Starck JP, Paakkonen RJ, Ylikoski JS. Physical characteristics of gunfire impulse noise and its attenuation by hearing protectors. Scand Audiol. 1995;24(1):3–11.
- 33.Abel SM, Odell P. Sound attenuation from earmuffs and earplugs in combination: maximum benefits vs. missed information. Aviat Space Environ Med. 2006;77(9):899–904.
- 34.Paakkonen R, Lehtomaki K, Myllyniemi J. Ear plug fit and attenuation—an experimental study. Acta Acustica united with Acustica. 2000;86:481–4.
- 35.Paakkonen R, Savolainen S, Myllyniemi J. Noise attenuation of hearing protectors in the human ear—a method description. Acta Acustica united with Acustica. 2000;86:477–80.
- 36.Toivonen M, Paakkonen R, Savolainen S, Lehtomaki K. Noise attenuation and proper insertion of earplugs into ear canals. Ann Occup Hyg. 2002;46(6):527–30.
- 37.Zera J. The measurement of impulse noise protection by earmuffs [abstract]. J Acoust Soc Am. 2000;108(5):2621.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-aa372416-138b-4df6-9c45-0068189d2131