Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
People spend most of their time in indoor environments and, consequently, these environments are more significant for the contribution of the daily pollutant exposure than outdoors. In case of children, a great part of their time is spent at school. Therefore, evaluations of this microenvironment are important to assess their time-weighted exposure to air pollutants. The aim of this study was to assess the children exposure to bioaerosols at schools from two different types of areas, urban and rural. A methodology based upon passive sampling was applied to evaluate fungi, bacteria and pollens, simultaneously with active sampling for fungi and bacterial assessment. Results showed very good correlations between sampling methods, especially for summer season. Passive sampling methodologies presented advantages such as no need of specific and expensive equipment, and they allow achieving important qualitative information. The study was conducted in different periods of the year to study the seasonal variation of the bioaerosols. Fungi and pollen presented higher levels during the summer time whereas bacteria did not present a seasonal variation. Indoor to outdoor ratios were determined to assess the level of outdoor contamination upon the indoor environment. Levels of fungi were higher outdoor and bacteria presented higher concentrations indoors. Indoor levels of bioaerosols were assessed in primary schools of urban and rural areas, using the active method along with a passive sampling method. Very good correlations between methods were found which allow the use of the passive sampling method to supply important and reliable qualitative information of bioaerosols concentrations in indoor environments. Seasonal variation in bioaerosols concentrations were found for fungi and pollen. Concentrations of fungi and bacteria above AMV (Acceptable Maximum Value) were found for most of the studied classrooms showing the importance of this microenvironment for the high exposure of children to bioaerosols.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
11--22
Opis fizyczny
Bibliogr. 51 poz., rys., tab., wykr.
Twórcy
autor
- Universidade de Lisboa, Portugal Instituto Superior Técnico C2TN – Centro de Ciências e Tecnologias Nucleares
autor
- Universidade de Lisboa, Portugal Instituto Superior Técnico C2TN – Centro de Ciências e Tecnologias Nucleares
autor
- Universidade de Lisboa, Portugal Instituto Superior Técnico C2TN – Centro de Ciências e Tecnologias Nucleares
autor
- Delft University of Technology, The Netherlands Faculty of Applied Sciences Department of Radiation, Radionuclides and Reactors
Bibliografia
- [1] Almeida, S.M., Freitas, M.C., Repolho, C., Dionísio, I., Dung, H.M., Pio, C.A., Alves, C., Caseiro, A. & Pacheco, A.M.G. (2009a). Evaluating children exposure to air pollutants for an epidemiological study, Journal of Radioanalytical and Nuclear Chemistry, 280, 2, pp. 405–409.
- [2] Almeida, S.M., Freitas, M.C., Repolho, C., Dionisio, I., Dung, H.M., Caseiro, A., Alves, C., Pio, C.A. & Pacheco, A.M.G. (2009b). Characterizing air particulate matter composition and sources in Lisbon, Portugal, Journal of Radioanalytical and Nuclear Chemistry, 281, 2, pp. 215–218.
- [3] Almeida, S.M., Canha, N., Silva, A., Freitas, M.C., Pegas, P., Alves, C., Evtyugina, M. & Pio, C.A. (2011). Children exposure to atmospheric particles in indoor of Lisbon primary schools, Atmospheric Environment, 45, pp. 7594–7599.
- [4] Almeida, S.M., Lage, J., Freitas, M.C., Pedro, A.I., Ribeiro, T., Silva, A.V., Canha, N., Almeida-Silva, M., Sitoe, T., Dionisio, I., Garcia, S., Domingues, G., Faria, J.P., Fernández, B.G., Ciaparra, D. & Wolterbeek, H.T. (2012). Integration of biomonitoring and instrumental techniques to assess the air quality in an industrial area located in the coastal of Central Asturias, Spain, Journal of Toxicology and Environmental Health, Part A: Current Issues, 75, 22–23, pp. 1392–1403.
- [5] Almeida, S.M., Silva, A.I., Freitas, M.C., Dzung, H.M. Caseiro, A. & Pio, C.A. (2013). Impact of maritime air mass trajectories on the western European coast urban aerosol, Journal of Toxicology and Environmental Health, Part A: Current Issues, 76, 4–5, pp. 252–262.
- [6] Almeida-Silva, M., Canha, N., Galinha, C., Dung, H.M., Freitas, M.C. & Sitoe, T. (2011a). Trace elements in wild and orchard honeys, Applied Radiation and Isotopes, 69, 11, pp. 1592–1595.
- [7] Almeida-Silva, M., Canha, N., Freitas, M.C., Dung, H.M. & Dionísio, I. (2011b). Air pollution at an urban traffic tunnel in Lisbon, Portugal – an INAA study, Applied Radiation and Isotopes, 69, 11, pp. 1586–1591.
- [8] Almeida-Silva, M., Wolterbeek, H.Th. & Almeida, S.M. (2014a). Elderly exposure to indoor air pollutants, Atmospheric Environment, 85, pp. 54–63.
- [9] Almeida-Silva, M., Almeida, S.M., Gomes, J.F., Albuquerque, P.C. & Wolterbeek, H.T. (2014b). Determination of airborne nanoparticles in elderly care centers, Journal of Toxicology and Environmental Health, Part A: Current Issues, 77, 14–16, pp. 867–878.
- [10] Almeida-Silva, M., Almeida, S.M., Pegas, P.N., Nunes, T., Alves, C.A. & Wolterbeek, H.T. (2015). Exposure and dose assessment to particle components among na elderly population, Atmospheric Environment, 102, pp. 156–166.
- [11] Aydogdu, H., Asan, A., Otkun, M.T. & Ture, M. (2005). Monitoring of fungi and bacteria in the indoor air of primary schools in Edirne city, Turkey, Indoor and Built Environment, 14, 5, pp. 411–425.
- [12] Bates, J.M. & Mahaffy, D.J. (1996). Relationships of reported allergy symptoms, relative humidity and airborne biological in thirteen Florida classrooms, Proceedings of Indoor Air ’96: The 7th International Conference on Indoor Air Quality and Climate, Nagoya, Japan, 1, pp. 551–556.
- [13] Bejan, A., Dincer, I., Lorente, S., Miguel, A.F. & Reis, A.H. (2004). Porous and Complex Flow Structures in Modern Technologies, Springer-Verlag, New York, 2004.
- [14] Burge, H. (1995). Bioaerosols, Lewis Publishers, Boca Raton 1995.
- [15] Cabral, J.P.S. (2010). Can we use indoor fungi as bioindicators of indoor air quality? Historical perspectives and open questions, Science of the Total Environment, 408, 20, pp. 4285–4295.
- [16] Canha, N., Freitas, M.C., Anawar, H.M., Dionisio, I., Dung, H.M., Pinto-Gomes, C. & Bettencourt, A. (2010a). Characterization and phytoremediation of abandoned contaminated mining area in Portugal by INAA, Journal of Radioanalytical and Nuclear Chemistry, 286, 2, pp. 577–582.
- [17] Canha, N., Freitas, M.C., Almeida, S.M., Almeida, M., Ribeiro, M., Galinha, C. & Wolterbeek, H.T. (2010b) Indoor school environment: easy and low cost to assess inorganic pollutants, Journal of Radioanalytical and Nuclear Chemistry, 286 (2), 495–500.
- [18] Canha, N., Almeida, M., Freitas, M. C. & Almeida, S.M. (2011). Seasonal variation of total particulate matter and children respiratory diseases at Lisbon basic schools using passive methods, Procedia Environmental Sciences, 4, pp. 170–183.
- [19] Canha, N., Almeida-Silva, M., Freitas, M.C., Almeida, S.M. & Wolterbeek, H.T. (2012a). Lichens as biomonitors at indoor environments of primary schools, Journal of Radioanalytical and Nuclear Chemistry, 291, 1, pp. 123–128.
- [20] Canha, N., Martinho, M., Almeida-Silva, M., Freitas, M.C., Almeida, S.M., Pegas, P., Alves, C., Pio, C., Trancoso, M., Sousa, R., Mouro, F. & Contreiras, T. (2012b). Indoor air quality in primary schools, International Journal of Environment and Pollution, 50, 1/2/3/4, pp. 396–410.
- [21] Canha, N., Freitas, M.C., Almeida-Silva, M., Almeida, S.M., Dung, H.M., Dionísio, I., Cardoso, J., Pio, C.A., Caseiro, A., Verburg, T.G. & Wolterbeek, H.T. (2012c). Burn Wood influence on outdoor air quality in a small village: Foros de Arrão, Portugal, Journal of Radioanalytical and Nuclear Chemistry, 291, 1, pp. 83–88.
- [22] Canha, N., Freitas, M.C. & Pacheco, A.M.G. (2013a). Response of air-pollution biomonitors under three different meteorological conditions, Journal of Radioanalytical and Nuclear Chemistry, 295, 1, pp. 489–496.
- [23] Canha, N., Almeida, S.M., Freitas, M.C., Täubel, M. & Hänninen, O. (2013b). Winter ventilation rates at primary schools: comparison between Portugal and Finland, Journal of Toxicology and Environmental Health, Part A: Current Issues, 76, 6, pp. 1–8.
- [24] Canha, N., Almeida, S.M., Freitas, M.C., Trancoso, M., Sousa, A., Mouro, F. & Wolterbeek, H.T. (2014a) Particulate matter analysis in indoor environments of urban and rural primary schools using passive sampling methodology, Atmospheric Environment, 83, pp. 21–34.
- [25] Canha, N., Almeida, S.M., Freitas, M.C. & Wolterbeek, H.T. (2014b) Indoor and Outdoor Biomonitoring using Lichens at Urban and Rural Primary Schools. Journal of Toxicology and Environmental Health, Part A: Current Issues, 77, 14–16, pp. 900–915.
- [26] Canha, N., Almeida, S.M., Freitas, M.C., Wolterbeek, H.T., Cardoso, J., Pio, C.A. & Caseiro, A. (2014c). Impact of wood burning on indoor PM2.5 in a primary school in rural Portugal, Atmospheric Environment, 94, pp. 663–670.
- [27] Canha, N., Mandin, C., Ramalho, O., Wyart, G., Ribéron, J., Dassonville, C., Hänninen, O., Almeida, S.M. & Derbez, M. (2015). Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France, Indoor Air Journal (in press), doi: 10.1111/ina.12222
- [28] Dacarro, C., Picco, A.M., Grisoli, P. & Redolfi, M. (2003). Determination of aerial microbiological contamination in scholastic sports environment, Journal of Applied Microbiology, 95, 5, pp. 904–912.
- [29] Daisey, J.M., Angell, W.J. & Apte, M.G. (2003). Indoor air quality, ventilation and health symptons in schools: an analysis of existing information, Indoor Air, 13, 1, pp. 53–64.
- [30] Hussin, N.H.M., Sann, L.M., Shamsudin, M.N. & Hashim, Z. (2011). Characterization of bacteria and fungi bioaerosol in the indoor air of selected primary schools in Malaysia, Indoor and Built Environment, 20, 6, pp. 607–617.
- [31] Husman, T. (1996). Health effects of indoor-air microorganisms, Scandinavian Journal of Work, Environment & Health, 22, 1, pp. 5–13.
- [32] Jantunen, M., Jaakkola, J.J.K. & Krzyzanowski, M. (1997). Assessment of exposure to indoor air pollutants, WHO Regional Publications, European Series, no. 78, WHO, Copenhagen 1997.
- [33] Kosonen, R. & Tan, F. (2004). The effect of perceived indoor air quality on productivity loss, Energy Buildings, 36, 10, pp. 981–986.
- [34] Lage, L., Almeida, S.M., Reis, M.A., Chaves, P.C., Ribeiro, T., Garcia, S., Faria, J.P., Fernandez, B.G. & Wolterbeek, H.T. (2014). Levels and spatial distribution of airborne chemical elements in a heavy industrial area located in the north of Spain, Journal of Toxicology and Environmental Health, Part A: Current Issues, 77, pp. 856–866.
- [35] Macher, J.M. (1999). Bioaerosols: Assessment and control, American Conference of Governmental Industrial Hygienists, Cincinnati 1999.
- [36] Mouilleseaux, A. (1990). Sampling methods for bioaerosols, Aerobiologia, 6, pp. 32–35.
- [37] Morawska, L., Afshari, A., Bae, G.N., Buonanno, G., Chao, C.Y.H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E.R., Pasanen, P., Salthammer, T., Waring, M. & Wierzbicka, A. (2013). Indoor aerosols: from personal exposure to risk assessment, Indoor Air, 23, 6, pp. 462–487.
- [38] Napoli, C., Marcotrigiano, V. & Montagna, M.T. (2012). Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres, BMC Public Health, 12, pp. 594.
- [39] Pastuszka, J.S., Paw, U.K.T., Lis, D.O., Wlazlo, A. & Ulfig, K. (2000). Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland, Atmospheric Environment, 34, pp. 3833–3842.
- [40] Pegas, P.N., Evtyugina, M.G., Alves, C. A., Nunes, T., Cerqueira, M., Franchi, M., Pio, C., Almeida, S.M. & Freitas, M.C. (2010). Outdoor/indoor air quality in primary schools in Lisbon: a preliminary study, Quimica Nova, 33, pp. 1145–1149.
- [41] Pegas, P.N., Alves, C.A., Evtyugina, M.G., Nunes, T., Cerqueira, M., Franchi, M., Pio, C.A., Almeida, S.M., Cabo Verde, S. & Freitas, M.C. (2011a). Seasonal evaluation of outdoor/indoor air quality in primary schools in Lisbon, Journal of Environmental Monitoring, 13, 3, pp. 657–667.
- [42] Pegas, P.N., Alves, C.A., Evtyugina, M.G., Nunes, T., Cerqueira, M., Franchi, M., Pio, C.A., Almeida, S.M. & Freitas, M.C. (2011b). Indoor air quality in elementary schools of Lisbon in spring, Environmental Geochemistry and Health, 33, 5, pp. 455–468.
- [43] Ramos, C.A., Wolterbeek, H.T. & Almeida, S.M (2014). Exposure to indoor air pollutants during physical activity in fitness centers, Building and Environment, 82, pp. 349–360.
- [44] RSECE (2006). Regulamento dos Sistemas Energéticos de Climatização em Edifícios (RSECE) – Decreto-Lei no. 79/2006, de 04/04/2006, Ministério das Obras Públicas, Transportes e Comunicações, Portugal 2006.
- [45] Selgrade, M.K., Plopper, C.G., Gilmour, M.I., Conolly, R.B. & Foos, B.S.P. (2008). Assessing the health effects and risks associated with children’s inhalation exposures – Asthma and allergy, Journal of Toxicology and Environmental Health, Part A: Current Issues, 71, 3, pp. 196–207.
- [46] Scheff, P.A., Paulius, V.K., Curtis, L. & Conroy, L.M. (2000). Indoor air quality in a middle school, Part II: Development of emission factors for particulate matter and bioaerosols, Applied Occupational and Environmental Hygiene, 15, 11, pp. 835–842.
- [47] Smedje, G., Norback, D., & Edling, C. (1997). Subjective indoor air quality in schools in relation to exposure, Indoor Air, 7, 2, pp. 143–150.
- [48] Srikanth, P., Sudharsanam, S. & Steinberg, R. (2008). Bio-aerosols in indoor environment: composition, health effects and analysis, Indian Journal of Medical Microbiology, 26, 4, pp. 302–312.
- [49] Trancoso, M., Sousa, A., Mouro, F., Freitas, M.C., Almeida, S. & Canha, N. (2012). Indoor air quality: validation and setting up quality control for determination of anions and cations in particulate matter, Accreditation and Quality Assurance, 17, 2, pp. 199–206.
- [50] Viegas, C., Almeida-Silva, M., Gomes, A.Q., Wolterbeek, H.T. & Almeida, S.M. (2014). Fungal Contamination assessment in Portuguese elderly care centers, Journal of Toxicology and Environmental Health, Part A: Current Issue, 77, 1–3, pp. 14–23.
- [51] Wilson, R. & Spengler, J. (1996). Particles in Our Air: Concentrations and Health Effects. Harvard University Press, Boston 1996.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a91da215-3f0e-4801-b515-f07227923d3c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.