Use of Quantitative and Qualitative Wastewater Monitoring in Water Protection on the Example of Lodz

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Stosowanie ilościowego i jakościowego monitorowania ścieków w ochronie wód na przykładzie Łodzi
Języki publikacji
EN
Abstrakty
EN
Widely understood protection of water, and in particular surface waters, most exposed to direct pollution, requires many operations carried out both in the catchment area and in sewage systems as well as WWTPs. Due to its character and working conditions, it should be monitored not only in terms of hydraulics, but also in terms of the quality of transported wastewater. During atmospheric precipitation, large volumes of domestic and industrial wastewater as well as rainwater in various proportions flow through the canals, changing not only their quantity but also their composition. In such cases, the issue of monitoring becomes particularly vital. The article presents an analysis of the needs and tasks resulting from the application of quantitative and qualitative monitoring in the assessment of the functioning of sewage systems. Methods and tools used in Lodz that may be useful in water protection are presented. The benefits of using this type of solutions as well as the limitations and difficulties are discussed.
PL
Szeroko rozumiana ochrona wód, a zwłaszcza wód powierzchniowych, najbardziej narażonych na bezpośrednie zanieczyszczenie, wymaga wielu działań przeprowadzanych zarówno w zlewni, jak i w systemach kanalizacyjnych oraz w oczyszczalniach ścieków. Ze względu na swój charakter i warunki pracy system kanalizacji należy monitorować nie tylko pod względem hydraulicznym, ale także pod względem składu transportowanych ścieków. Podczas opadów atmosferycznych przez kanały, w różnych proporcjach, przepływają znaczne ilości ścieków bytowych, przemysłowych oraz deszczowych, zmieniając przy tym także swój skład. W takich przypadkach kwestia monitorowania staje się szczególnie istotna. W artykule przedstawiono analizę potrzeb i zadań wynikających z zastosowania monitorowania ilościowego i jakościowego w ocenie funkcjonowania systemów kanalizacyjnych oraz metody i narzędzia stosowane w Łodzi, które mogą być przydatne w ochronie wód. Omówiono zalety korzystania z tego typu rozwiązań, a także ograniczenia i trudności.
Rocznik
Strony
431--443
Opis fizyczny
Bibliogr. 21 poz., rys.
Twórcy
  • Lodz University of Technology, Poland
  • Lodz University of Technology, Poland
Bibliografia
  • Bi E.G., Monette F., Gachon P., Gaspéri J., Perrodin Y. (2015). Quantitative and qualitative assessment of the impact of climate change on a combined sewer overflow and its receiving water body, Environmental Science and Pollution Research, 22, 11905-11921.
  • Brzezińska, A., Sakson, G., Zawilski, M. (2016). Assessment of pollutant load emission from combined sewer overflows based on the online monitoring, Environmental Monitoring and Assessment, 188(9), 502.
  • Brzezińska, A., Sakson, G., Zawilski, M. (2018). Predictive model of pollutant loads discharged by combined sewer overflows, Water Science and Technology, 77(7-8), 1819-1828.
  • Brzezińska, A. (2019). Emission of pollutants from combined sewer ovelflows. Monographs of the Lodz University of Technology, No. 2279.
  • Casadio, A., Maglionico, M., Bolognesi, A., Artina, S. (2010). Toxicity and pollutant impact analysis in an urban river due to combined sewer overflows loads, Water Science and Technology, 61(1), 207-221.
  • Campisano, A., Cabot, J., Muschalla, D., Pleau, M., Vanrolleghem, P.A. (2013). Potential and limitations of modern equipment for real time control of urban wastewater system, Urban Water Journal, 10, 300-331.
  • Caissie, D., Kurylyk, B.L., St-Hilaire, A., El-Jabi, N., MacQuarrie, K.T. (2014). Streambed temperature dynamics and corresponding heat fluxes in small streams experiencing seasonal, ice cover, Journal of Hydrology, 519, 1441-1452.
  • Di Lecce, V., Petruzzelli, D., Guaragnella, C., Cardellicchio A., Dentamaro, G., Quarto, A., Soldo, D., Dario, R. (2017). Real-time monitoring system for urban wastewater, July 2017, Conference: 2017 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS).
  • Hannouche, A., Joannis, C. & Chebbo, G. (2017). Assessment of total suspended solids (TSS) event load and its uncertainties in combined sewer system from continuous turbidity measurements. Urban Water Journal, 17(8), 789-796.
  • Keupers, I., Willems, P. (2013). Impact of urban WWTP and CSO fluxes on river peak flow extremes under current and future climate conditions, Water Science and Technology, 67(12), 2670-2676.
  • Kożuchowski, K. (2011). Polish climate: a new look. PWN Scientific Publisher, Warsaw, 1-292.
  • Langeveld, J.G., Schilperoort, R.P.S., Weijers, S.R. (2013). Climate change and urban wastewater infrastructure: there is more to explore, Journal of Hydrolology, 476, 112-119.
  • Lvovaa, L., Guanais, Gonçalvesa, C., Petropoulosa, K., Michelia, L., Volpea, G., Kirsanovb, D., Leginb, A., Viaggiud, E., Congestrid, R., Guzzellae, L., Pozzonie, F., Palleschia, G., Di Nataleb, C., Paolesse, R. (2016). Electronic tongue for microcystin screening in waters, Biosensors and Bioelectronics, 80, 154-160.
  • Montserrat, A., Hofer, T., Poch, M., Muschalla, D., Corominas, L. (2017). Using the duration of combined sewer overflow events for the calibration of sewer hydrodynamic models. Urban Water Journal, 14(8), 782-788.
  • Phillips, P.J., Chalmers, A.T., Gray, J.L., Kolpin, D.W., Foreman, W.T., Wall, G.R. (2012). Combined sewer overflows: an environmental source of hormones and wastewater micropollutants, Environmental Science and Technology, 46(10), 5336-5343.
  • Regulation of the Minister of the Environment of November 18, 2014 on the conditions which must be met during discharging wastewater into water or into the ground,,and on substances that are particularly harmful to the aquatic environment.
  • Thompson, K.E., Vamvakeridou-Lyroudia, L., Kapelan, Z., Savic, D. (2011). Optimalmacrolocation methods for sensor placement in urban water systems,” Exeter, UK.
  • Torres, A. & Bertrand-Krajewski, J.L. (2008). Partial Least Squares local calibration of a UV–visible spectrometer used for in situ measurements of COD and TSS concentrations in urban drainage systems, Water Science and Technology, 57(4), 581-588.
  • Wierzbicki, P., Waack-Zając, A., Koska, T. (2010). Hydrographic system of the city of Lodz, Scientific Notebooks of the Lodz University of Technology, Civil Engineering, 1066(61), 1-13.
  • Zawilski, M., Brzezińska, A. (2014). Areal rainfall intensity distribution over an urban area and its effect on a combined sewerage system, Urban Water Journal, 11(7), 532-542.
  • Zawilski, M. (2012). Analysis of the hydraulic load of the sewage system on a large urban catchment scale, Scientific Papers of Rzeszów University of Technology, Civil and Environmental Engineering, 59(2) / I, 237-247.