The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the transmission-line models are applied. The idea of TLM was presented in [1], While the length of transformer wires is comparable to wave length at high frequency, such approach is reasonable. The paper presents examples of models created for simple windings.
Rocznik
Tom
Strony
41--47
Opis fizyczny
Bibliogr. 6 poz., rys.
Twórcy
autor
  • West Pomeranian University of Technology in Szczecin
  • West Pomeranian University of Technology in Szczecin
Bibliografia
  • [1] De Gersem H., Henze O., Weiland T., Binder A.: Simulation of wave propagation effects in machine windings, COMPEL, vol. 29, No.1, 2010, pp. 23-38.
  • [2] Jayasinghe J.A.S.B, Wang Z.D., Darwin A.W., Jarman P.N.: Practical Issues in Making FRA Measurements on Power Transformers, XlVth International Symposium on High Voltage Engineering, Beijing, China, August 2005, G-013.
  • [3] Banaszak Sz.: Conformity of Models and Measurements of Windings Deformations in Frequency Response Analysis Method, Przegląd Elektrotechniczny 7’2010, pp. 278-280.
  • [4] Florkowski M., Furgał J.: Modeling of winding failures identification using the Frequency Response Analysis (FRA) method, Elect. Power Syst. Res., Vol.79, No. 7, 2009, pp. 1069-1075.
  • [5] Heindl M., Tenbohlen S., Velasquez J., Kraetge A., Wimmer R.: Transformer Modeling Based On Frequency Response Measurements For Winding Failure Detection, Proceedings of the 2010 International Conference on Condition Monitoring and Diagnosis, 2010, Tokyo, Japan, Paper No. A7-3.
  • [6] Bjerkan E., High Frequency Modeling of Power Transformers. Stresses and Diagnostics, Doctoral Thesis, Norwegian University of Science and Technology, 2005.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a528bbb1-a973-4a02-b5d5-7927c8743159
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.