Tytuł artykułu

Capillary electrophoresis for the determination of N-Acetyltyrosine and N-acetylcysteine in products for parenteral nutrition: Method development and comparison of two CE systems

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Because of the problems with stability and solubility, some of the amino acids (AAs) used in parenteral nutrition products are often replaced by their acetylated forms. These include N-acetyltyrosine (NAT) and N-acetylcysteine (NAC). This leads to a need to develop new analytical methods for rapid and easy determination of these substances in the presence of common AAs. Capillary electrophoresis (CE) is one of the techniques that have been successfully applied to the assay of multi-component samples containing AAs and their derivatives. This paper discusses a new CE method for the simultaneous determination of two acetylated AAs in solutions for parenteral nutrition. A background electrolyte (BGE) was developed based on borate buffer with alkaline pH. The method is selective and enables the separation and assay of analytes without special sample pretreatment. Validation parameters confirmed sufficient precision and accuracy of the method. Its applicability was verified by testing several medicinal products from various manufacturers. Moreover, the flexibility of the method was checked using two brands of CE equipment. Appropriate adjustment of instrumental parameters turned out to be essential for method transferability. The method could be used in routine testing of parenteral nutrition medicinal products containing AAs.
Rocznik
Strony
595--602
Opis fizyczny
Bibliogr. 17 poz., rys., tab.
Twórcy
autor
  • National Medicines Institute Department of Biochemistry and Biopharmaceuticals Chełmska str. 30/34 Warsaw Poland
autor
  • National Medicines Institute Department of Biochemistry and Biopharmaceuticals Chełmska str. 30/34 Warsaw Poland
autor
  • National Medicines Institute Department of Biochemistry and Biopharmaceuticals Chełmska str. 30/34 Warsaw Poland
  • National Medicines Institute Department of Biochemistry and Biopharmaceuticals Chełmska str. 30/34 Warsaw Poland
Bibliografia
  • [1] M. Pertkiewicz, Preparaty stosowane w żywieniu pozajelitowym in Żywienie pozajelitowe i dojelitowe w chirurgii PZWL, Warszawa, 1994, pp. 124–152
  • [2] P.C. do Nascimento, D. Bohrer, J. Tramontina, Analyst, 122(8), 835, (1997)
  • [3] P. Socha, P. Heim, B. Koletzko, Clin. Nutr., 15, 34, (1996)
  • [4] I. Magnusson, L. Ekman, M. Wangdahl, J. Wahren, Metabolism, 38, 957 (1989)
  • [5] M. Neuhäuser, J.A. Wandira, U. Göttmann, K.H. Bässler, K. Langer, Am. J. Clin. Nutr., 42(4), 585, (1985)
  • [6] J. Zhang, D.S. Kalonia, AAPS PharmSciTech., 8(4), Article 102 (2007), DOI: 10.1208/pt0804102
  • [7] S. Moore, W.H. Stein, J. Biol. Chem., 192(2), 663, (1951)
  • [8] S.A. Cohen, D.J. Strydom, Anal. Biochem., 174, 1, (1988)
  • [9] H.G. Worthen, H. Liu, J. Liq. Chromatogr., 15, 3323, (1992)
  • [10] S.A. Cohen, D.P. Michaud, Anal. Biochem., 211, 279, (1993)
  • [11] B.S. Murty, J.N. Kapoor, M.W. Kim, Am. J. Hosp. Pharm., 34(3), 305, (1977)
  • [12] Y. Dong, X. Chen, Z. Hu, Microchim. Acta, 154, 281, (2006)
  • [13] M. Ahnoff, I. Grundevik, A. Arfwidsson, J. Fonselius, B.A. Persson, Anal. Chem., 53, 485, (1981)
  • [14] M. Jaworska, Z. Szulińska, M. Wilk, J. Chromatogr. A, 993, 165, (2003)
  • [15] P. Tůma, E. Samcová, K. Andělová, J. Chromatogr. B, 839(1–2), 12, (2006)
  • [16] T.D. Thi, R. Pomponio, R. Gotti, J. Saevels, B. Van Hove, W. Van Ael, N. Matthijs, Y. Vander Heyden, R.M. Djan’geing’a, P. Chiap, P. Hubert, J. Crommen, H. Fabre, P. Dehouck, J. Hoogmartens, A. Van Schepdael, Electrophoresis, 27(12), 2317, (2006)
  • [17] P. Dehouck, P.K. Jaggavarapu, A. Desmedt, A. Van Schepdael, J. Hoogmartens, Electrophoresis, 25(18–19), 3313, (2004)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a42c3436-ace5-4a45-af2c-a6a9e8630113
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.