The article presents a discussion about the problem of illegal energy consumption. One of the typical watt-hour energy meter damage is the failure of braking magnets as a result of their exposition to a high external magnetic field. Permanent magnets are very sensitive elements to this action, and their damage affects the accuracy of energy measurement. The study discusses the evaluation methods of the magnetic flux density asymmetry inside the magnet gap. The authors present statistical classification methods as identification means in the evaluation process of magnet damage.
PL
Artykuł przedstawia dyskusję na temat problemu nielegalnego zużycia energii. Jednym z typowych uszkodzeń liczników energii czynnej jest awaria magnesów hamujących jako efekt ekspozycji na działanie zewnętrznego pola magnetycznego. Magnesy trwałe są bardzo wrażliwymi elementami na to działanie, a ich uszkodzenie wpływa na dokładność pomiaru energii. Omówiono metody oceny asymetrii rozkładu indukcji magnetycznej w szczelinie magnesów. Autorzy przedstawiają metody klasyfikacji statystycznej w celu identyfikacji w procesie oceny uszkodzenia magnesów.
Rocznik
Strony
121--124
Opis fizyczny
Bibliogr. 15 poz., rys.
Twórcy
  • Politechnika Lubelska, Instytut Elektrotechniki i Elektrotechnologii, ul. Nadbystrzycka 38a, 20-618 Lublin
  • Politechnika Lubelska, Instytut Elektrotechniki i Elektrotechnologii, ul. Nadbystrzycka 38a, 20-618 Lublin
  • Politechnika Lubelska, Instytut Elektrotechniki i Elektrotechnologii, ul. Nadbystrzycka 38a, 20-618 Lublin
Bibliografia
  • [1] Bernieri A., Betta G., Ferrigno L., Laracca M., Electrical energy metering in compliance with recent european standards, IEEE International Instrumentation and Measurement Technology Conference Proceedings, Graz, (2012), 1541-1545, doi: 10.1109/I2MTC.2012.6229455
  • [2] Gallo D., Landi C., Liccardo A., Pasquino N., Polese N., A methodology for quality assurance in energy measurements under non-sinusoidal conditions, XVIII IMEKO World Congress, Rio de Janeiro, Brazil, (2006)
  • [3] EN 50160, Voltage characteristics of electricity supplied by public distribution systems, CENELEC, (1999)
  • [4] Girgis A. A. , Baldwin T. L., Makram E. B, Fnnson H. S., Testing the performance of three-phase induction watthour meters in the presence of harmonic distortion, IEEE Trans.Ind. Appl., vol. 26, (1990),Issue 4, 689 — 695
  • [5] IEEE 1459, IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced or Unbalanced Conditions, (2000)
  • [6] IEC 61000—4-30, Testing and measurement techniques — Power quality measurement methods, (2003)
  • [7] Kasperczyk B., Skórkowski A., Evaluation of resistance to illegal energy consumption of induction and electronic meters, Pomiary Automatyka Kontrola, vol. 60, (2014) nr 12, 1201-1204, (in Polish)
  • [8] Bilewicz K., Detection of illegal consumption of electric energy with NdFeB magnets, Przegląd Elektrotechniczny, 82, (2006), nr 6, 82-85, (in Polish)
  • [9] Kasperczyk B., Determining the causes of some damage of induction watt-hour meters, Wiadomości Elektrotechniczne, (2010), nr 1, 31-34, (in Polish)
  • [10] Soiński M., Pluta W., Rygał R., Kępski P., Żurek S., Influence of external stationary magnetic fields on measuring devices, Przegląd Elektrotechniczny, 83, (2007) nr 4, 88-92
  • [11] Pawłowski E., Warda P., The influence of a strong external magnetic field from a permanent magnet on a measurement accuracy of an inductive watt-hour meter, Przegląd Elektrotechniczny, 92, (2016), nr 8, 70-73,
  • [12] Pawłowski E., Influence of strong neodymium magnet field on operation of inductive watt-hour meters, (in Polish), Pomiary Automatyka Kontrola, vol. 56, (2010), nr 11, 1259-1261, 2010
  • [13] Pawłowski E., Legal, technical and metrological effects of neodymium magnet field influence on inductive electricity meters, Przeglad Elektrotechniczny, 93, (2007) nr 9, 124-129, (in Polish)
  • [14] Amhenrior H. E., Edeko F. O.,. Ogujor E. A., Emagbetere J. O., Design and implementation of an automatic tamper detection and reporting capability for a single phase energy meter, 2017 IEEE 3rd International Conference on Electro-Technology for National Development (NIGERCON), (2017), doi: 10.1109/NIGERCON.2017.8281947
  • [15] Stryczewska H. D.,Goleman R.,Pietras M.; Giżewski T., Evaluation of the damages in three-phase watt-hour induction meters after external high magnetic field exposition, 2017 International Conference on Electromagnetic Devices and Processes in Environment Protection with Seminar Applications of Superconductors (ELMECO & AoS), Lublin, (2017), doi: 10.1109/ELMECO.2017.8267731
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a3029d4a-b30b-46f9-b978-6011997b26b9
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.