Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Cyfryzacja podstacji z wykorzystaniem protokołu GOOSE między inteligentnymi urządzeniami elektronicznymi
Języki publikacji
Abstrakty
The article addresses the implementation of projects for new digital substations, as well as upgrading existing substations using digital intelligent electronic devices. The purpose of the scientific article is to implement the GOOSE protocol into the IEC 61850 standard, enablingall substation process equipment to be interconnected with a single information network.These technological advancements significantly influencethe process of operating secondary equipment at substations and, at first, may pose certain challenges during its testing. Theexperimental analysis confirmedthat the mechanism of cyclic transmission of GOOSE messages in REF615 and SEPAM T62devices operates in accordance with the protocol.The repeated transmission mechanism ensures message delivery and enables detection of communication failuresafter the maximum periodof transmission of GOOSE messages.
Artykuł obejmuje zagadnienia związane z wdrażaniem projektów nowych cyfrowych podstacji, a także modernizacją istniejących podstacji przy użyciu cyfrowych inteligentnych urządzeń elektronicznych. Celem artykułu naukowego jest wdrożenie protokołu GOOSE do standardu IEC 61850, który umożliwia połączenie wszystkich urządzeń procesowych podstacji z jedną siecią informacyjną. Innowacje te znacząco wpływają na proces obsługi urządzeńwtórnych w podstacjach i początkowo mogą powodować pewne trudności podczas ich testowania. Eksperyment przeprowadzony w ramach pracy naukowej potwierdził, że mechanizm cyklicznej transmisji komunikatów GOOSE w REF615 i SEPAM T62 jest realizowany zgodnie zprotokołem.Ta technologia wielokrotnej transmisji gwarantuje, że odbiorca otrzyma wiadomość, a wszelkie usterki zostaną wykryte po maksymalnym okresie transmisji wiadomości GOOSE.
Rocznik
Tom
Strony
77--83
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
autor
- Taraz University named after M.Kh.Dulaty, Taraz, Kazakhstan
autor
- Taraz University named after M.Kh.Dulaty, Taraz, Kazakhstan
autor
- Taraz University named after M.Kh.Dulaty, Taraz, Kazakhstan
autor
- Toraigyrov University, Pavlodar, Kazakhstan
Bibliografia
- [1] Akimzhanov T. et al.: Identifying the Influence of the System and Mode Characteristics on the Power Loss Mode Based in 110 kV Power Grids. EasternEuropean Journal of Enterprise Technologies 6(8-126), 2023, 6–14 [https://doi.org/10.15587/1729-4061.2023.292253]
- [2] Bernd D., Seidler S.: Digital substation as an intelligent agent for unattended substations. VELC-2011 Modern Intelligent Electric Power Systems 2, 2011, 130–135.
- [3] Denisenko V.V.: Computer control of the technological process, experiment, equipment. Hot Line. Telecom, Moscow 2009.
- [4] Gorelik T. G., Kirienko O. V.: Design issues of the substation automation and control systems based on the IEC61850 standard. International scientific and technical conference "Modern directions of the relay protection and automation systems development in power systems" SIGRE-2013, 3-7.06.2013, Ekaterinburg, 2013.
- [5] Gribakin N. S.: Practice of the IEC61850 standard application at the electric power industry objects. Automation and IT in power engineering 10, 2010, 50–54.
- [6] Issabekov Z. B., et al.: Configurations of 6-10 kV cable lines and types of cable damages. AIP Conference Proceedings 2337, 2021, 030002 [http://dx.doi.org/10.1063/5.0047154].
- [7] Orlov L.: Experience of designing and implementation of relay protection and automatic control systems based on IEC 61850 technology. Automation and IT in power engineering 1, 2010, 48–51.
- [8] Zhantlessova A., et al.: Instrumental Research on the Voltage Harmonic Distortion Coefficient in the Modern 110 kV Urban Electric Network. International Journal on Energy Conversion 11(2), 2023, 56–63 [https://doi.org/10.15866/irecon.v11i2.22979].
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a2ffd755-e7bb-432e-bbcf-53a92e01795f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.