The paper analyses the variability of the methodology of collecting samples of endotoxins from the air in the premises and the vicinity of objects of waste management and wastewater treatment infrastructure, methods of their preparation, determination of endotoxin content, and results of research to date. The high sensitivity of analytical methods enables the analysis of the concentration of endotoxins in air samples with a small volume. After freezing, they can be stored for a long time. The effectiveness of extraction of endotoxins from bioaerosol samples can be improved by adding Tween 20 or Tween 80 to water. So far, factors determining the variability of concentrations of endotoxins in the air in the premises and the vicinity of objects of waste management infrastructure were determined. Further research in the scope is necessary. This will allow the determination of acceptable levels of endotoxin in the future. The impact of endotoxins on human health and the specificity of sewage and waste management must also be taken into account.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
49--58
Opis fizyczny
Bibliogr. 32 poz.
Twórcy
autor
- Department of Environmental Protection Engineering, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
Bibliografia
- [1] SYKES P., MORRIS R.H.K., ALLEN J.A., WILDSMITH J.D., JONES K.P., Workers' exposure to dust, endotoxin and β-(1-3)glucan at four large-scale composting facilities, Waste Manage., 2011, 31, 423–430. DOI: 10.1016/j.wasman.2010.10.016.
- [2] DUQUENNE PH., MARCHAND G., DUCHAINE C., Measurement of endotoxins in bioaerosol at workplace: A critical review of literature and a standarizaton issue, Ann. Occup. Hyg., 2013, 57 (2), 137–172. DOI: 10.1093/annhyg/mes051.
- [3] PANKHURST L.J., DEACON L.J., LIU J., DREW G.H., HAYES E.T., JACKSON S., LONGHURST P.J., LONGHURST J.W.S., POLLARD S.J.T., TYRREL S.F., Spatial variations in airborne microorganism and endotoxin concentrations at green waste composting facilities, Int. J. Hyg. Environ. Health, 2011, 214, 376–383. DOI: 10.1016/j.ijheh.2011.06.001.
- [4] DUQUENNE PH., AMBROISE D., GÖRNER P., CLER F., GREFF-MIRGUET G., Exposure to airborne endotoxins among sewer workers. An exploratory study, Ann. Occup. Hyg., 2014, 58 (3), 283–293. DOI: 10.1093/annhyg/met085.
- [5] VISSER M.J., SPAAN S., ARTS H.J.J.M., SMIT L.A.M., HEEDERIK D.J.J., Influence of different cleaning practices on endotoxin exposure at sewage treatment plants, Ann. Occup. Hyg., 2006, 50 (7), 731–736. DOI: 10.1093/annhyg/mel026.
- [6] CYPROWSKI M., SOBALA W., BUCZYŃSKA A., SZADKOWSKA-STAŃCZYK I., Endotoxin exposure and changes in short-term pulmonary function among sewage workers, Int. J. Occup. Med. Environ. Health, 2015, 28 (5), 803–811. DOI: 10.13075/ijomeh.1896.00460.
- [7] THORN J., BEIJER L., JONSSON T., RYLANDER R., Measurement strategies for the determination of airborne bacterial endotoxin in sewage treatment plants, Ann. Occup. Hyg., 2002, 46 (6), 549–554. DOI: 10.1093/annhyg/mef068.
- [8] SKLAR R., ZHOU Z., MARLEY ZALAY M., ASHLEY MUSPRATT A., HAMMOND S.K., Occupational exposure to endotoxin along a municipal scale fecal sludge collection and resource recovery process in Kigali, Rwanda, Int. J. Environ. Res. Public Health, 2019, 16, 4740. DOI: 10.3390/ijerph16234740.
- [9] WEN N., LIU H., FU Y., WANG C., Optimalization and influence mechanism od sampling and analysis of airborne endotoxin based on limulus amebocyte lysate assay, Aerosol Air Qual. Res., 2017, 17, 1000–1010. DOI: 10.4209/aaqr.2016.05.0184.
- [10] OPPLIGER A., HILFIKER S., VU DUC T., Influence of seasons and sampling strategy on assesment of bioaerosols in sewage treatment plants in Switzerland, Ann. Occup. Hyg., 2005, 49 (5), 393–400. DOI: 10.1093/annhyg/meh108.
- [11] SCHLOSSER O., HUYARD A., RYBACKI D., DO QUANG Z., Protection of the vehicle cab environment against bacteria, fungi, and endotoxins in composting facilities, Waste Manage. 2012, 32, 1106–1115. DOI: 10.1016/j.wasman.2012.01.013.
- [12] DOUWES J., VERSLOOT P., HOLLANDER A., HEEDERIK D., DOEKES G., Influence of various dust sampling and extraction methods on the measurement of airborne endotoxin, Appl. Environ. Microbiol., 1995, 65 (5), 1763–1769. DOI: 10.1128/AEM.61.5.1763-1769.1995.
- [13] THORNE P.S., REYNOLDS S., MILTON D.K., BLOEBAUM P.D., ZHANG X., WHITTEN P., BURMEISTER L.F., Field evaluation of endotoxin air sampling assay methods, Am. Ind. Hyg. Assoc. J., 1997, 58, 792–799. DOI: 10.1080/15428119791012298.
- [14] DE ROOIJ M.M.T., HEEDERIK D.J.J., BORLÉE HOEK G., WOUTERS I.M., Spatial and temporal variation in endotoxin and PM10 concentrations in ambient air in a liverstock dense area, Environ. Res., 2017, 153, 161–170. DOI: 10.1016/j.envres.2016.12.004.
- [15] SPAAN S., SCHINKEL J., WOUTERS I.M., PRELLER L., TIELEMANS E., NIJ E.T., Variability in endotoxin exposure levels and consequences for exposure assesment, annales of occupational hygiene, 2008, 52 (5), 303–316. DOI: 10.1093/annhyg/men024.
- [16] GLADDING T., THORN J., STOTT D., Organic dust exposure and work-related effects among recycling workers, Am. J. Ind. Med., 2003, 43, 584–591. DOI: 10.1002/ajim.10220.
- [17] UHRBRAND K., SCHULTZ A.C., KOIVISTO A.J., NIELSEN U., MADSEN A.M., Assesment of airborne bacteria and noroviruses in air emissions from a new highly-advanced hospital wastewater treatment plant, Water Res., 2017, 112, 110–119. DOI: 10.1016/j.watres.2017.01.046.
- [18] DUCHAINE C., THORNE P.S., MÉRIAUX A., GRIMARD Y., WHITTEN P., CORMIER Y., Comparison of endotoxin exposure assesment by bioaerosol impinger and filter-sampling methods, Appl. Environ. Microbiol., 2001, 67 (6), 2775–2780. DOI: 10.1128/AEM.67.6.2775-2780.2001.
- [19] MORGENSTERN V., BISCHOF W., KOCH A., HEINRICH J., Measurement of endotoxin on ambient loaded PM filters after long-term storage, Sci. Total Environ., 2006, 370, 574–579. DOI: 10.1016/j.scitotenv.2006.08.027.
- [20] SPAAN S., HEEDERIK D.J.J., THORNE P.S., WOUTERS I.M., Optimization of airborne endotoxin exposure assesment. Effects of filter type, transport conditions, extraction solutions, and storage of samples and extracts, Appl. Environ. Microbiol., 2007, 73 (19), 6134–6143. DOI: 10.1128/AEM.00851-07.
- [21] SPAAN S., SMIT L.A.M., EDUARD W., LARSSON L., ARTS H.J.J.M., WOUTERS I.M., HEEDERIK D.J.J., Endotoxin exposure in sewage treatment workers: investigation of exposure variability and comparison of analytical techniques, Ann. Agric. Environ. Med., 2008, 15, 251–261. DOI: pubmed.ncbi.nlm.nih.gov/19118445/.
- [22] DING J.L., HO B., A new era in pyrogen testing, Trends Biotechnol., 2001, 19 (8), 277–281. DOI: 10.1016/S0167-7799(01)01694-8.
- [23] LAITINEN S., NEVALAINEN A., KOTIMAA M., LIESIVUORI J., MARTIKAINEN P.I., Relationship between bacterial counts and endotoxin concentrations in the air of wastewater treatment plants, Appl. Environ. Microbiol., 1992, 58 (11), 3774–3776. DOI: 10.1128/AEM.58.11.3774-3776.1992.
- [24] PANKHURST L.J., DEACON L.J., LIU J., DREW G.H., HAYES E.T., JACKSON S., LONGHURST P.J., LONGHURST J.W.S., POLLARD S.J.T., TYRREL S.F., Microbial and endotoxin emission from composting facilities: characterization of release and dispersal patterns, Air Poll., 2009, 17, 163–172. DOI: 10.2495/AIR090151.
- [25] SCHLOSSER O., HUYARD A., CARTNICK K., YAÑEZ A., CATALÁN V., DO QUANG Z., Bioaerosol in composting facilities. Occupational health risk assessment, Water Environ. Res., 2009, 81 (9), 866–877. DOI: 10.2175/106143009x407258.
- [26] SMIT L.A.M., SPAAN S., HEEDERIK D., Endotoxin exposure and symptoms in wastewater treatment workers, Am. J. Ind. Med., 2005, 48, 30–39. DOI: 10.1002/ajim.20176.
- [27] HELDAL K.H., AUSTIGARD Ǻ.D., SVENDSEN K.H., EINARSDOTTIR E., GOFFENG L.O., SIKKELAND L.I., NORDBY K.-C., Endotoxin and hydrogen sulphide exposure and effects on the airways among waste water workers in sewage treatment plants and sewer net system, Ann. Work Exp. Health, 2019, 63 (4), 437–447. DOI: 10.1093/annweh/wxz020.
- [28] WOUTERS I.M., SPAAN S., DOUWES J., DOEKES G., HEEDERIK D., Overview of personal occupational exposure levels to inhalable dust, endotoxin, β (1→3)-glucan and fungal extracellular polysaccharides in the waste management chain, Ann. Occup. Hyg., 2006, 50 (1), 39–53. DOI: https://academic.oup.com/annweh/article/50/1/39/156710.
- [29] THORN J., Seasonal variations in exposure to microbial cell wall components among household waste collectors, Ann. Occup. Hyg., 2001, 45 (2), 153–156. DOI: https://academic.oup.com/annweh/article /45/2/153/209910.
- [30] JADCZYK P., SÓWKA I., PAWNUK M., WRONISZEWSKA A., Impact of a small wastewater treatment plant on the sanitary state of atmospheric air, Rocz. Ochr. Środ., 2020, 22, 927–939. DOI: https://researchgate.net/publication/publication/343346105_Impact_of_a_small_municipal_wastewater_treatment_plant_on_the_sanitary_state_of_atmospheric_air.
- [31] AGHAEI M., YAGHMAEIAN K., HASSANVAND M.S., HEDAYATI M.H., YOUSEFIAN F., JANJANI H. NABIZADEH R., YUNESIAN M. Exposure to endotoxins and respiratory health in composting facilities, Ecotoxicol. Environ. Saf., 2020, 202, 110907. DOI: https://www.sciencedirect.com/science/article/pii/S0147651320307466.
- [32] ROLPH C.A., GWYTHER C.L., TYRREL S.F., NASIR Z.A., DREW G.H., JACKSON S.K., KHERA S., HAYES E., WILIAMS B., BENNETT A., COLLINS S., WALSH K., KINNERSLEY R., GLADDING T.L., Sources of airborne endotoxins in ambient air and exposure of nearby communities. A review, Atmosphere, 2018, 9, 375. DOI: 10.3390/atmos9100375.