Safety evaluation for a high signal operator with electric field exposure induced by contact wires

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
To evaluate the occupational safety of a high signal operator exposed to the electric field induced by contact wires with a frequency of 50 Hz and a voltage of 27.5 kV, this study established a model of a high signal operator working in the vicinity of single and double-track railways. The electric field distribution in the operator’s body and his head were calculated and analyzed during the operation using the finite element method (FEM). The calculated results were compared with the international standard occupational exposure limits formulated by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and action levels (ALs), exposure limit values (ELVs) in Directive 2013/35/EU (EU Directive). In the case of a single-track railway exposure, the maximum electric field strength in the worker’s body, in the scalp layer, and inside the brain are 227 mV/m, 2.76 kV/m, and 0.14 mV/m, respectively. For a double-track railway exposure, the maximum internal electric field strength of the operator is 310 mV/m, which is 37.85% of the occupational exposure basic restriction limit. The maximum electric field strength in the head layers is 3.42 kV/m, which is 34.2% of the occupational exposure reference level and 34.2% of the low ALs. The maximum electric field strength of the brain is 0.19 mV/m, which is 0.19% of the occupational basic restriction limit and 0.135% of the sensory effects ELVs. Results show that the electric field exposure of the high signal operator to contact wires in single- and double-track railways is lower than the occupational exposure limits provided by the ICNIRP and EU Directive standards and is thus regarded as safe for workers.
Rocznik
Strony
431--444
Opis fizyczny
Bibliogr. 23 poz., rys., tab.
Twórcy
  • Lanzhou Jiaotong University, China
autor
  • Lanzhou Jiaotong University, China
Bibliografia
  • [1] Wyszkowska J. W., Jankowska M., Gas P., Electromagnetic fields and neurodegenerative diseases, Przeglad Elektrotechniczny, vol. 95, no. 1, pp. 129–133 (2019).
  • [2] Mahaki H., Jabarivasal N., Sardarian K., Zamani A., Effects of various densities of 50 Hz electromagnetic field on serum IL-9, IL-10, and TNF-α levels, The International Journal of Occupational and Environmental Medicine, vol. 11, no. 1, pp. 24–32 (2020).
  • [3] WertheimerN., Leeper E.D., Electrical wiring configurations and childhood cancer, American Journal of Epidemiology, vol. 109, no. 3, pp. 273–284 (1979).
  • [4] Di G., Dong L., Xie Z., Xu Y., Xiang J., Effects of power frequency electric field exposure on kidney, Ecotoxicology and Environmental Safety, vol. 194, no. 110354, pp. 1–6 (2020).
  • [5] Syrek P., Skowron M., The impact of overhead lines for employees with stents, IOP Conference Series: Materials Science and Engineering, vol. 200, no. 012013, pp. 1–6 (2017).
  • [6] Gas P., Miaskowski A., Implant Safety Tool Application to Assist the Assessment of Radio-Frequency Radiation Exposure, Journal of Ecological Engineering, vol. 20, no. 10, pp. 24–33 (2019).
  • [7] Oancea C. D., Calin F., Golea V., On the Electromagnetic Field in the Surrounding Area of Railway Equipment and Installations, 2019 International Conference on Electromechanical and Energy Systems (SIELMEN), Craiova, Romania, pp.1–5 (2019).
  • [8] Wen Y.H., Hou W.X., Research on Electromagnetic Compatibility of Chinese High Speed Railway System, Chinese Journal of Electronics, vol. 29, no. 1, pp. 16–21 (2020).
  • [9] Wrobel Z., The Electromagnetic Compatibility in Researches of Railway Traffic Control Devices, Lecture Notes in Electrical Engineering, vol. 452, pp. 275–287 (2018).
  • [10] ICNIRP, Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz), Health Physics, vol. 99, no. 6, pp. 818–836 (2010).
  • [11] 2013/35/EU: Directive of the European Parliament and of the Council of 26 June 2013 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields), Official Journal of the European Union, L 179, pp. 1–21 (2013).
  • [12] https://timgsa.baidu.com/timg?image&quality=80&size=b9999_10000&sec=1606369465878&di= 311321a9c108936454933bf4a777536f&imgtype=0&src=http%3A%2F%2Fy.zdmimg.com% 2F201711%2F08%2F5a02beb474f797348.jpg_e600.jpg, accessed on December 2020.
  • [13] http://5b0988e595225.cdn.sohucs.com/images/20181002/5b1720a89c7a456c9cebb2696008ae14.jpeg, accessed on December 2020.
  • [14] Gas P., Wyszkowska J., Influence of multi-tine electrode configuration in realistic hepatic RF ablative heating, Archives of Electrical Engineering, vol. 68, no. 3, pp. 521–533 (2019).
  • [15] Stuchly M. A., Dawson T. W., Human body exposure to power lines: relation of induced quantities to external magnetic fields, Health Physics, vol. 83, no. 3, pp. 333–340 (2002).
  • [16] Lu M., Ueno S., Computational study toward deep transcranial magnetic stimulation using coaxial circular coils, IEEE Transactions on Biomedical Engineering, vol. 62, no. 12, pp. 2911–2919 (2015).
  • [17] Bidi M., Biological risk assessment of high-voltage transmission lines on worker’s health of electric society, Archives of Electrical Engineering, vol. 69, no. 1, pp. 57–68 (2020).
  • [18] Bakker J. F., Paulides M. M., Neufeld E., Christ A., Chen X.L., Kuster N., Van Rhoon G.C., Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: Theoretical assessment of the induced electric fields, Physics Medicine Biology, vol. 57, no. 7, pp. 1815–1829 (2012).
  • [19] Tian R., Lu M., Safety assessment of electromagnetic exposure in high-speed train carriage with full passengers, Annals of Work Exposures and Health, vol. 64, no. 8, pp. 838–851 (2020).
  • [20] Alvin R. T., Ergonomics diagram – human factors in design, translated by Zhu T., China Architecture and Building Press (1998).
  • [21] Rush S., Driscoll D. A., Current distribution in the brain from surface electrodes, Anaesthesia and Analgesia, vol. 47, no. 6, pp. 717–723 (1968).
  • [22] http://niremf.ifac.cnr.it/tissprop/htmlclie/htmlclie.php, accessed on December 2020.
  • [23] Keikko T., Isokorpi J., Korpinen L., Practical problems in calculating electric fields of transmission lines, Eleventh International Symposium on High Voltage Engineering, London, UK, vol. 2, pp. 103–106 (1999).
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2021).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a23f1ba2-cce4-4823-a9c7-1748bccc1669
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.