PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Measurement Capabilities Upgrade of GEM Soft X-ray Measurement System for Hot Plasma Diagnostics

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents improvements of the developed system for hot plasma radiation measurement in the soft Xray range based on a Gas Electron Multiplier (GEM) detector. Scope of work consists of a new solution for handling hardware time-synchronization with tokamak systems needed for better synchronization with other diagnostics and measurement quality. The paper describes the support of new modes of triggering on PC-side. There are communication and data path overview in the system. The new API is described, which provide separate channels for data and control and is more robust than the earlier solution. Work concentrates on stability and usability improvements of the implemented device providing better usage for end-user.
Słowa kluczowe
EN
Twórcy
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • 1) Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • 2) CERN, Geneva, Switzerland
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
  • Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
autor
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  • Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
Bibliografia
  • [1] D. Mazon, M. Chernyshova, G. Jiolat, T. Czarski, P. Malard, E. Kowalska-Strzeciwilk, S. Jablonski, W. Figacz, R. Zagorski, M. Kubkowska, G. Kasprowicz, K. Pozniak, W. Zabolotny, S. Larroque, J.-M. Verger, M. O’Mullane, J. Mlynar, A. Byszuk, and A. Wojenski, “Design of soft-x-ray tomographic system in west using gem detectors,” Fusion Engineering and Design, vol. 96-97, pp. 856 – 860, 2015, proceedings of the 28th Symposium On Fusion Technology (SOFT28). [Online]. Available: http://www.sciencedirect.com/science/article/pii/S0920379615002215
  • [2] W. M. Zabolotny, G. Kasprowicz, K. Pozniak, M. Chernyshova, T. Czarski, M. Gaska, P. Kolasinski, R. Krawczyk, P. Linczuk, and A. Wojenski, “Fpga and embedded systems based fast data acquisition and processing for gem detectors,” Journal of Fusion Energy, vol. 38, no. 3, pp. 480–489, Aug 2019.
  • [3] M. Chernyshova, T. Czarski, K. Malinowski, E. Kowalska-Strzeciwilk, J. Krol, K. T. Pozniak, G. Kasprowicz, W. Zabołotny, A. Wojenski, R. D. Krawczyk, P. Kolasinski, I. N. Demchenko, and Y. Melikhov, “Development of gem detector for tokamak sxr tomography system: Preliminary laboratory tests,” Fusion Engineering and Design, vol. 123, pp. 877 – 881, 2017, proceedings of the 29th Symposium on Fusion Technology (SOFT-29) Prague, Czech Republic, September 5-9, 2016. [Online]. Available: http://www.sciencedirect.com/science/article/pii/S0920379617303307
  • [4] G. Kasprowicz, W. M. Zabolotny, K. Pozniak, M. Chernyshova, T. Czarski, M. Gaska, P. Kolasinski, R. Krawczyk, P. Linczuk, and A. Wojenski, “Multichannel data acquisition system for gem detectors,” Journal of Fusion Energy, vol. 38, no. 3, pp. 467–479, Aug 2019.
  • [5] A. Wojenski, K. Pozniak, D. Mazon, and M. Chernyshova, “FPGA based novel real-time evaluation and data quality monitoring system for tokamak high-performance GEM soft x-ray diagnostic,” Journal of Instrumentation, vol. 13, no. 12, pp. P12 024–P12 024, dec 2018.
  • [6] P. Linczuk, R. D. Krawczyk, W. M. Zabolotny, A. Wojenski, K. T. Pozniak, M. Chernyshova, T. Czarski, M. Gaska, G. Kasprowicz, E. Kowalska-Strzeciwilk, and K. Malinowski, “Data distribution and dispatching software for processing measurement data acquired with SXR GEM-based system,” in Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2018, R. S. Romaniuk and M. Linczuk, Eds., vol. 10808, International Society for Optics and Photonics. SPIE, 2018, pp. 1219 – 1224.
  • [7] R. D. Krawczyk, T. Czarski, P. Linczuk, A. Wojenski, P. Kolasinski, M. Gaska, M. Chernyshova, D. Mazon, A. Jardin, P. Malard, K. Pozniak, G. Kasprowicz, W. Zabolotny, E. Kowalska-Strzeciwilk, and K. Malinowski, “The software-defined fast post-processing for gem soft x-ray diagnostics in the tungsten environment in steady-state tokamak thermal fusion reactor,” Review of Scientific Instruments, vol. 89, no. 6, p. 063504, 2018. [Online]. Available: https://doi.org/10.1063/1.5022131
  • [8] M. Garcia-Sciveres and N. Wermes, “A review of advances in pixel detectors for experiments with high rate and radiation,” Reports on Progress in Physics, vol. 81, no. 6, p. 066101, may 2018. [Online]. Available: https://doi.org/10.1088%2F1361-6633%2Faab064
  • [9] P. Linczuk, R. Krawczyk, A. Wojenski, W. Zabolotny, K. Pozniak, M. Chernyshova, T. Czarski, P. Kolasinski, G. Kasprowicz, M. Gaska, E. Kowalska-Strzeciwilk, and K. Malinowski, “Performance Evaluation of Developed GEM-based X-ray Diagnostic System,” Acta Physica Polonica B Proceedings Supplement, vol. 11, p. 637, 01 2018.
  • [10] T. Czarski, M. Chernyshova, K. Malinowski, K. Pozniak, G. Kasprowicz, P. Kolasinski, R. Krawczyk, A. Wojenski, P. Linczuk, W. Zabolotny, A. Jardin, D. Mazon, K. Jakubowska, G. Boutoux, F. Burgy, S. Hulin, and D. Batani, “Measuring issues in the GEM detector system for fusion plasma imaging,” Journal of Instrumentation, vol. 13, no. 08, pp. C08 001–C08 001, aug 2018. [Online]. Available: https://doi.org/10.1088%2F1748-0221%2F13%2F08%2Fc08001
  • [11] P. Linczuk, R. Krawczyk, A. Wojenski, W. Zabolotny, M. Chernyshova, K. Pozniak, T. Czarski, M. Gaska, G. Kasprowicz, P. Kolasinski, E. Kowalska-Strzeciwilk, and K. Malinowski, “Latency and throughput of online processing in soft x-ray GEM-based measurement system,” Journal of Instrumentation, vol. 14, no. 05, pp. C05 001–C05 001, may 2019. [Online]. Available: https://doi.org/10.1088%2F1748-0221%2F14%2F05%2Fc05001
  • [12] P. Kolasinski, K. T. Pozniak, T. Czarski, M. Linczuk, A. Byszuk, M. Chernyshova, B. Juszczyk, G. Kasprowicz, A. Wojenski, W. Zabolotny, P. Zienkiewicz, D. Mazon, P. Malard, A. Herrmann, and D. Vezinet, “Serial data acquisition for GEM-2D detector,” in Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2014, R. S. Romaniuk, Ed., vol. 9290, International Society for Optics and Photonics. SPIE, 2014, pp. 723 – 730. [Online]. Available: https://doi.org/10.1117/12.2075911
  • [13] P. Kolasinski, K. Pozniak, A. Wojenski, P. Linczuk, R. Krawczyk, W. Zabołotny, G. Kasprowicz, M. Chernyshova, and T. Czarski, “Zero Suppression Trigger Mode for GEM detector measurement system”, International Journal of Electronics and Telecommunications, This volume.
  • [14] A. Wojenski, P. Linczuk, P. Kolasinski, M. Chernyshova, D. Mazon, G. Kasprowicz, K. T. Pozniak, M. Gaska, T. Czarski, R. Krawczyk “High-performance soft X-ray diagnostic systems’ data quality monitoring features for WEST tokamak”, International Journal of Electronics and Telecommunications, This volume.
  • [15] A. Wojenski, P. Linczuk, R. Krawczyk, P. Kolasinski, M. Gaska, K. T. Pozniak, G. Kasprowicz, M. Chernyshova, T. Czarski, E. Kowalska-Strzeciwilk, and K. Malinowski, “Communication model for multi-level control, management, and acquisition firmware-software implementations for tokamak plasma diagnostics systems,” in Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2019, R. S. Romaniuk and M. Linczuk, Eds., vol. 11176, International Society for Optics and Photonics. SPIE, 2019, pp. 1285 – 1288. [Online]. Available: https://doi.org/10.1117/12.2536890
  • [16] Supervisor: A Process Control System., (accessed 10 November 2020). [Online]. Available: http://supervisord.org/
  • [17] Gamegos, CeSI (Centralized Supervisor Interface) GitHub page., (accessed 10 November 2020). [Online]. Available: https://github.com/gamegos/cesi
  • [18] Tailon - application for looking at and searching through log files., (accessed 10 November 2020). [Online]. Available: https://tailon.readthedocs.io/en/latest/
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2021).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-a030ab80-e379-449a-a579-930d56356b99
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.