PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

Comparison of the Stress Relaxation of Biodegradable Surgical Threads Made of Mg and Zn Alloys and Some Commercial Synthetic Materials

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The mechanical properties of the commercial synthetic surgical threads (i.e., monofilament MonosynR and polyfilament PolysorbTM) and threads made of pure zinc and selected magnesium alloys were compared. Tensile and relaxation tests of fine fibers/wires without and with a surgical knot were performed on a Zwick 250 tensile machine and on the specially constructed tensile machine dedicated for ultra-thin samples. An about 50% decrease in the maximum tensile load was registered for both synthetic and Mg-based threads due to the presence of a surgical knot while only an about 10% decrease was documented for the zinc threads.
Słowa kluczowe
Twórcy
autor
  • AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Kraków, Poland
autor
  • AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Kraków, Poland
autor
  • AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Kraków, Poland
autor
  • AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Kraków, Poland
  • AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Kraków, Poland
Bibliografia
  • [1] P. A. Gunatillake, R. Adhikari, Eur. Cells Mater. 5, 1 (2003).
  • [2] G. O. Hofmann, Arch. Orthop. Trauma Surg. 114 (3), 123 (1995).
  • [3] W. Cheng, D. E. Cameron, K. E. Warden, J. D. Fonger, V. L. Gott, Ann. Thorac. Surg. 55 (3), 737 (1993).
  • [4] J. M. Seitz, R. Eifler, F. W. Bach, H. J. Maier, J. Biomed. Mater. Res. A 102 (10), 3744 (2014).
  • [5] S. Zhao, J.-M. Seitz, R. Eifler, H. J. Maier, R. J. Guillory II, E. J. Earley, A. Drelich, J. Goldman, J. W. Drelich, Mater. Sci. Eng. C 76, 301 (2017).
  • [6] A. Milenin, P. Kustra, D. Byrska-Wójcik, O. Grydin, M. Schaper, T. Mentlein, G. Gerstein, F. Nurberger, JOM,68 (12), 3063 (2016).
  • [7] PolysorbTM absorbable sutures, Reference Guide, 2017 Medtronic, 17-emea-wc-guide-polysorb-en 1587715
  • [8] PolysorbTM, Braided, Synthetic Absorbable Suture, COVIDEN, M110416 GB-07/2012
  • [9] MonosynR, The surgeon’s choise, B-Braun, Sharing Expertise, Brochure no B20402-0112/1/1
  • [10] MonosynR, Mild Term Absorbable Monofilament Suture, Aesculap, Inc. - a B. Braun Co, DOC 1218 Rev A 2M 4/15
  • [11] F. Porter, Zinc Handbook: Properties, processing, and use in design, Marcel Dekker, New York, NY, 1991.
  • [12] A. Milenin, J. M. Seitz, J. M., F., W. Bach, D. Bormann, P. Kustra, Wire Journal International6, 74 (2011).
  • [14] A. Milenin, M. Gzyl, T. Rec, B. Płonka, Arch. Metall. Mater. 59(2), 561 (2014).
  • [15] P. Kustra, A. Milenin, D. Byrska-Wójcik, O. Grydin, M. Schaper, J. Mater. Process. Tech. 247, 234 (2017)
Uwagi
EN
1. Investigetion are conducted within project no. POIR.04.01.04-00-0074/17 named: "Comprehensive development and preparation for the implementation of innovative implant solutions in the treatment of animals, surgical instruments for their implantology and biodegradable surgical thread for veterinary medicine” Action 4.1 "Research and Development”, Subaction 4.1.4 "Application projects” Operational Program Smart Growth 2014-2020 co-financed from the European Regional Development Fund.
PL
2. Błędna numeracja bibliografii (brak poz. 13).
PL
3. Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-9ec89c44-b2d0-4009-9823-3ee3fc716a7c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.