PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Requirements for the development of an effective autonomous methane detection system protecting against a sudden emission of methane

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Uwarunkowania wdrożeniowe autonomicznego ścianowego systemu metanometrycznego zabezpieczającego przed nagłym wypływem metanu
Języki publikacji
EN PL
Abstrakty
EN
The paper features the development origin of a new methane measuring system whose main purpose is to provide quick protection of heavily saturated methane longwalls against a sudden emission of methane from goafs into the working area of the longwall. The concept of the new system was discussed along with its testing results. This work was the subject of task 8 of the project devoted to improving safety in mines. The focus was put on implementation conditions: from obtaining indispensable certificates and admissions, through the installation in the given exploitation area, to the system integration with already existing stationary gas measuring systems. The possibilities of the new system were stressed as far as the safety management of the mine was concerned. Here, the authors pointed at the significance of systematic risk analyses with respect to methane explosions in longwall areas.
PL
W artykule przedstawiono genezę opracowania nowego systemu metanometrycznego, którego głównym przeznaczeniem jest realizacja autonomicznego szybkiego zabezpieczania rejonu ścian silnie metanowych przed skutkami nagłego wypływu metanu ze zrobów do przestrzeni roboczej wyrobiska ścianowego. Omówiono koncepcję nowego systemu oraz wyniki jego testowania, co było przedmiotem zadania badawczego nr 8 realizowanego w ramach projektu „Poprawa bezpieczeństwa w kopalniach”. Zwrócono uwagę na wymagania wdrożeniowe – począwszy od uzyskania niezbędnych certyfikatów i dopuszczeń, poprzez zabudowę w konkretnym rejonie eksploatacyjnym, do jego bieżącej pracy w integracji z dotychczas stosowanymi systemami gazometrii stacjonarnej. Wskazując możliwości, jakie stwarza nowy system w działaniach związanych z zarządzeniem bezpieczeństwem zakładu górniczego, podkreślono znaczenie systematycznego prowadzenia analiz ryzyka wybuchu metanu w rejonach ścian wydobywczych.
Wydawca
Rocznik
Strony
30--36 [tekst ang.], 70--76 [tekst pol.]
Opis fizyczny
Bibliogr. 14 poz., zdj.
Twórcy
autor
  • Institute of Innovative Technologies EMAG
  • Institute of Innovative Technologies EMAG
autor
  • Silesian University of Technology in Gliwice
Bibliografia
  • 1. Law from 4 February 1994 on geology and mining. Journal of Law from 2005, No 228, item 1947, with later changes.
  • 2. Decree of the Minister of Economy from 28 June 2002 on occupational health and safety, mining works and specialized fire protection in underground mines. Journal of Law 139, item 1169, with later changes.
  • 3. Decree of the Minister of Infrastructure from 15 April 2004 on assessing the compliance of telecommunications terminals (…). Journal of Law from 2004, No 73, item 659.
  • 4. Decree of the Council of Ministers from 30 April 2004 on the admission of products to be used in mines. Journal of Law from 2004, No 99, item 1003.
  • 5. Decree of the Minister of Economy from 22 December 2005 on basic requirements for potection systems and devices to be used in explosive atmospheres (ATEX). Journal of Law from 2005, No 263, item 2203.
  • 6. Decree of the Minister of Transport from 3 July 2007 on radio transmitters and receivers which can be used without special radio permission. Journal of Law from 2007, No 138, item 972.
  • 7. Regulation 63/2009 by the Minister of Science and Higher Education from 30 November 2009 on development projects in the realm of improving work safety in mines.
  • 8. Report of the accident investigation commission appointed by the President of the State Mining Authority to investigate causes and circumstances of methane ignition and explosion on 18 September 2009 in Katowicki Holding Węglowy S.A. – coal mine Wujek, department Śląsk in Ruda Śląska. WUG, Katowice 2010, not published.
  • 9. Law from 9 June 2011 on geology and mining. Journal of Law from 2011, No 163, item 981, with later changes.
  • 10. User’s manual of the CR-1 radio sensor. Documentation of HASO S.C. 2013, not published.
  • 11. Appendix 4 to the 2013 annual report from the execuction of research task 8. Documentation of Haso S.C., Tychy 2013, not published.
  • 12. Report from stage 3, “Innovative system for analysis, visualization and prediction of methane hazards”, of the AVENTO project on advanced devices for monitoring ventilation and methane emission. Documentation of EMAG, Katowice 2013, not published.
  • 13. Detailed report. Appendix 1 to final report from task 8. Katowice 2014, not published.
  • 14. Nowrot A., Trenczek S., Krzystanek Z.: Wymagania dla systemu gazometrycznego powodującego natychmiastowe wyłączenie ścianowych maszyn i urządzeń elektrycznych w przypadku nagłego wypływu metanu. “Bezpieczeństwo Pracy i Ochrona Środowiska w Górnictwie”, 2015, No 3.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-9cee312f-392d-4187-a90f-fa7a5067c2b4
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.