Real-time monitoring of cell cultures with nickel comb capacitors

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Monitorowanie hodowli komórkowych w czasie rzeczywistym przy zastosowaniu niklowych kondensatorów grzebieniowych
Języki publikacji
EN
Abstrakty
EN
The aim of the study was to present a method for assessing the condition of cell culture by measuring the impedance of cells cultured in the presence of nickel. For this purpose, an impedance measurement technique using nickel comb capacitors was used. The capacitor electrodes were made using a thin film magnetron sputtering. In the experimental part, the culture of cells of mouse fibroblasts on the prepared substrate was performed. The cell culture lasted 43 hours and showed that the presented technique allows it to be used to analyze the effect of nickel on cells.
PL
Celem pracy było przedstawienie metody oceny stanu hodowli komórkowej poprzez pomiar impedancji komórek hodowanych w obecności niklu. W tym celu zastosowano technikę pomiaru impedancji z wykorzystaniem niklowych kondensatorów grzebieniowych. Cienkowarstwowe elektrody kondensatora wykonano metodą rozpylania magnetronowego. W części eksperymentalnej przeprowadzono hodowlę komórek mysich fibroblastów na przygotowanym podłożu. Hodowla komórkowa trwała 43 godziny i wykazała, że przedstawiona technika mogłaby być zastosowana do analizy wpływu niklu na komórki.
Słowa kluczowe
EN
Rocznik
Strony
32--35
Opis fizyczny
Bibliogr. 11 poz., rys.
Twórcy
  • Lublin University of Technology, Lublin, Poland
  • Lublin University of Technology, Lublin, Poland
  • Lublin University of Technology, Lublin, Poland
  • Lublin University of Technology, Lublin, Poland
  • Medical University of Lublin, Lublin, Poland
  • Medical University of Lublin, Lublin, Poland
  • Medical University of Lublin, Lublin, Poland
Bibliografia
  • [1] Arias L.R., Carla A.P., Yang L.: Real-Time Electrical Impedance Detection of Cellular Activities of Oral Cancer Cells. Biosensors and Bioelectronics 25(10), 2010, 2225–2231 [http://doi.org/10.1016/j.bios.2010.02.029].
  • [2] Arndt S., Seebach J., Psathaki K., Galla H.J., Wegener J.: Bioelectrical Impedance Assay to Monitor Changes in Cell Shape during Apoptosis. Biosensors and Bioelectronics 19(6), 2004, 583–594 [http://doi.org/10.1016/S0956-5663(03)00269-0].
  • [3] Bagnaninchi P.O., Drummond N.: Real-Time Label-Free Monitoring of Adipose-Derived Stem Cell Differentiation with Electric Cell-Substrate Impedance Sensing. Proceedings of the National Academy of Sciences of the United States of America 108(16), 2011, 6462–6467 [http://doi.org/10.1073/pnas.1018260108].
  • [4] Giaever I., Keese C.R.: A Morphological Biosensor for Mammalian Cells. Nature 366(6455), 1993, 591–592 [http://doi.org/10.1038/366591a0].
  • [5] Hong J., Kandasamy K., Marimuthu M., Choi M.S., Kim S.: Electrical Cell-Substrate Impedance Sensing as a Non-Invasive Tool for Cancer Cell Study. The Analyst 136(2), 2011, 237–245 [http://doi.org/10.1039/C0AN00560F].
  • [6] Hug T.S.: Biophysical Methods for Monitoring Cell-Substrate Interactions in Drug Discovery. ASSAY and Drug Development Technologies 1(3), 2003, 479–488 [http://doi.org/10.1089/154065803322163795].
  • [7] Scholten K., Meng E.: Materials for Microfabricated Implantable Devices: A Review. Lab on a Chip 15(22), 2015, 4256–4272 [http://doi.org/10.1039/C5LC00809C].
  • [8] Stensaas S.S., Stensaas L.J.: Histopathological Evaluation of Materials Implanted in the Cerebral Cortex. Acta Neuropathologica 41(2), 1978, 145–155 [http://doi.org/10.1007/BF00689766].
  • [9] Xiao C., Luong J.H.T.: On-Line Monitoring of Cell Growth and Cytotoxicity Using Electric Cell-Substrate Impedance Sensing (ECIS). Biotechnology Progress 19(3), 2003, 1000–1005 [http://doi.org/10.1021/bp025733x].
  • [10] Xu Y., Xie X., Duan Y., Wang L., Cheng Z., Cheng J.: A Review of Impedance Measurements of Whole Cells. Biosensors and Bioelectronics 77(March), 2016, 824–836 [http://doi.org/10.1016/J.BIOS.2015.10.027].
  • [11] Zudaire E., Cuesta N., Murty V., Woodson K., Adams L., Gonzalez N., Martínez A., Narayan G., Kirsch I., Franklin W., Hirsch F., Birrer M., Cuttitta F.: The Aryl Hydrocarbon Receptor Repressor Is a Putative Tumor Suppressor Gene in Multiple Human Cancers. Journal of Clinical Investigation 118(2), 2008, 640–650 [http://doi.org/10.1172/JCI30024].
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-9c806c13-34a1-413c-b66f-bef6aad021e8
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.