PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Long-Term Monitoring of Flicker and Some Other Parameters of Voltage Quality

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
International Conference on Environment and Electrical Engineering EEEIC (16 ; 06-08.06.2016 ; Florence, Italy)
Języki publikacji
EN
Abstrakty
EN
In 1997 cooperation began between the Faculty of Electrical Engineering and Computer Science and the power company CEZ on a joint project that involved monitoring selected voltage quality parameters. Over the course of several years measurements were carried out at 59 points of the distribution system at a low voltage (LV) level and their power supply nodes at medium voltage (MV) and high voltage (HV) levels, which constituted more than 100 measured points. The measurements continued until 2012 (with a one-year break in 2009) and with a total scope of five cycles of three-year measurements. The last phase of the measurements was focused, inter alia, on the evaluation of 15th and 21st voltage harmonics. From 2013, the cooperation focused again on monitoring flicker in localities with the occurrence of elevated levels of this voltage quality parameter. At these sites, the monitoring of flicker was carried out for two weeks in spring and autumn for a period of three years. The basis for evaluating the quality parameters is the standard EN 50160. In addition the results of annual continual monitoring for one selected locality on MV level will be presented in the paper. In addition the possibility of utilization of intelligent electrometers for monitoring of some quality parameters will be referred in the paper.
Słowa kluczowe
Rocznik
Strony
1--8
Opis fizyczny
Bibliogr. 4 poz., rys., tab.
Twórcy
autor
  • Faculty of Electrical Engineering and Computer Science, VSB Technical University of Ostrava, Ostrava, Czech Republic
autor
  • Faculty of Electrical Engineering and Computer Science, VSB Technical University of Ostrava, Ostrava, Czech Republic
autor
  • Faculty of Electrical Engineering and Computer Science, VSB Technical University of Ostrava, Ostrava, Czech Republic
autor
  • Czech Power Company (CEZ), Ostrava, Czech Republic
Bibliografia
  • [1] EN 50160 Ed.3:2010 “Voltage characteristics of electricity supplied by public electricity networks”.
  • [2] P. Krejci, P. Santarius, P. Bilík, R. Čumpelík “The Periodical and Continual PQ Monitoring of Selected Distribution Networks in Czech Republic,” Electrical Power Quality and Utilisation 2011, Lisabon, 2011, pp. 1-6.
  • [3] M. Tesarova, M. Kaspirek “Evaluation of long-term voltage dip monitoring in the distribution system,” International Scientific Symposium on Electrical Power Engineering 2011, Košice, 2013, pp. 268-271.
  • [4] P. Krejci, P. Santarius, R. Hájovský, R. Velička, R. Čumpelík “Power Quality Monitoring in Selected Distribution Networks in Czech Republic,” Electromagnetic Disturbances 2011, Bialystok, 2011, p. 145-148.