PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Transmittance measurement of the in vivo human eye with a double-pass system

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Purpose: To develop a methodology based on a double-pass system to obtain information about the transmittance of ocular media. Methods: The procedure consists of recording double-pass images at different powers of a laser diode of 780 nm and determining the scattering in an area between 25–35 arcmin of each image. The scattering showed linear behavior in respect to the irradiance of the laser, and the slope of the linear fit was proportional to the transmittance squared of the media evaluated. An artificial eye with different filters was tested first. Then, fifteen subjects with clear ocular media were divided into two groups: ten subjects classified by the iris color were recruited for the measurements of an ocular transmittance index and the estimation of the transmittance (group A), and another five subjects were selected for measurements with neutral filters (group B). Results: The measurements performed in group A presented a mean transmittance of 42.95%. No differences in the transmittance were found between subjects with different iris color (p = 0.154). Measurements in group B showed a good correlation (r = 0.959, p < 0.001) between the expected and the measured value for the transmittance. Conclusion: We proposed and evaluated a method to determine the transmittance of the eye in vivo using the double-pass system.
Słowa kluczowe
Czasopismo
Rocznik
Strony
1--21
Opis fizyczny
Bibliogr. 34 poz., rys., tab.
Twórcy
  • Instituto de Investigación en Luz, Ambiente y Visión, Avenida Independencia 1800, T4002BLR Tucumán, Argentina
  • Instituto de Investigación en Luz, Ambiente y Visión, Avenida Independencia 1800, T4002BLR Tucumán, Argentina
  • Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universitat Politecnica de Catalunya, Rambla de Sant Nebridi 10, 08222 Barcelona, España
  • Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universitat Politecnica de Catalunya, Rambla de Sant Nebridi 10, 08222 Barcelona, España
autor
  • Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universitat Politecnica de Catalunya, Rambla de Sant Nebridi 10, 08222 Barcelona, España
autor
  • Instituto de Investigación en Luz, Ambiente y Visión, Avenida Independencia 1800, T4002BLR Tucumán, Argentina Universidad Nacional de Tucumán, Avenida Independencia 1800, T4002BLR Tucumán, Argentina
Bibliografia
  • [1] LE GRAND Y., Light, Colour and Vision, Second English Edition, Chapman and Hall, London 1968.
  • [2] BOETTNER E.A., WOLTER J.R., Transmission of the ocular media, Investigative Ophthalmology and Visual Science 1(6), 1962, pp. 776–783.
  • [3] BOETTNER E.A., Spectral transmission of the eye, Final contract report AF41(609)-2966, University of Michigan, Ann Arbor MI, July 1967. [Available from NTIS as AD 663246].
  • [4] GEERAETS W.J., BERRY E.R., Ocular spectral characteristics as related to hazards from lasers and other light sources, American Journal of Ophthalmology 66(1), 1968, pp. 15–20, DOI:10.1016/0002-9394(68)91780-7.
  • [5] ALPERN M., THOMPSON S., LEE M.S., Spectral transmittance of visible light by the living human eye, Journal of the Optical Society of America 55(6), 1965, pp. 723–727, DOI:10.1364/JOSA.55.000723.
  • [6] DILLON J., ZHENG L., MERRIAM J.C., GAILLARD E.R., Transmission spectra of light to the mammalian retina, Photochemistry and Photobiology 71(2), 2000, pp. 225–229, DOI:10.1562/0031-8655(2000)0710225TSOLTT2.0.CO2.
  • [7] NORREN D.V., VOS J.J., Spectral transmission of the human ocular media, Vision Research 14(11), 1974, pp. 1237–1244, DOI:10.1016/0042-6989(74)90222-3.
  • [8] VANDE KRAATS J., VAN NORREN D., Optical density of the aging human ocular media in the visible and the UV, Journal of the Optical Society of America A 24(7), 2007, pp. 1842–1857, DOI:10.1364/JOSAA.24.001842.
  • 9] LUND D.J., MARSHALL J., MELLERIO J., OKUNO T., SCHULMEISTER K., SLINEY D., et al., A computerized approach to transmission and absorption characteristics of the human eye, CIE 203:2012, 2012, International Commission on Illumination.
  • 10] SANTAMARÍA J., ARTAL P., BESCÓS J., Determination of the point-spread function of human eyes using a hybrid optical-digital method, Journal of the Optical Society of America A 4(6), 1987, pp. 1109–1114, DOI:10.1364/JOSAA.4.001109.
  • [11] ARTAL P., MARCOS S., NAVARRO R., WILLIAMS D.R., Odd aberrations and double-pass measurements of retinal image quality, Journal of the Optical Society of America A 12(2), 1995, pp. 195–201, DOI:10.1364/JOSAA.12.000195.
  • [12] GUIRAO A., LÓPEZ-GIL N., ARTAL P., Double-pass measurements of retinal image quality: a review of the theory, limitations, and results, Vision Science and its Applications, OSA Technical Digest, Optical Society of America, 2000, paper NW4, DOI:10.1364/VSIA.2000.NW4.
  • [13] LÓPEZ-GIL N., ARTAL P., Comparison of double-pass estimates of the retinal image quality obtained with green and near-infrared light, Journal of the Optical Society of America A 14(5), 1997, pp. 961–971, DOI:10.1364/JOSAA.14.000961.
  • [14] GINIS H.S., PEREZ G.M., BUENO J.M., PENNOS A., ARTAL P., Wavelength dependence of the ocular straylight, Investigative Ophthalmology and Visual Science 54(5), 2013, pp. 3702–3708, DOI:10.1167/iovs.13-11697.
  • [15] VAN DEN BERG T.J., FRANSSEN L., COPPENS J.E., Straylight in the human eye: testing objectivity and optical character of the psychophysical measurement, Ophthalmic and Physiological Optics 29(3), 2009, pp. 345–350, DOI:10.1111/j.1475-1313.2009.00638.x.
  • [16] VAN DEN BERG T.J., Analysis of intraocular straylight, especially in relation to age, Optometry and Vision Science 72(2), 1995, pp. 52–59.
  • [17] FRANSSEN L., TABERNERO J., COPPENS J.E., VANDEN BERG T.J., Pupil size and retinal straylight in the normal eye, Investigative Ophthalmology and Visual Science 48(5), 2007, pp. 2375–2382, DOI:10.1167/iovs.06-0759.
  • [18] VANDEN BERG T.J., FRANSSEN L., KRUIJT B., COPPENS J.E., History of ocular straylight measurement: A review, Zeitschrift für Medizinische Physik 23(1), 2013, pp. 6–20, DOI:10.1016/j.zemedi.2012.10.009.
  • [19] ARTAL P., BENITO A., PÉREZ G.M., ALCÓN E., DE CASAS A., PUJOL J., MARÍN J.M., An objective scatter index based on double-pass retinal images of a point source to classify cataracts, PLoS ONE 6(2), 2011, article e16823, DOI:10.1371/journal.pone.0016823.
  • [20] VILASECA M., ROMERO M.J., ARJONA M., LUQUE S.O., ONDATEGUI J.C., SALVADOR A., GÜELL J.L., ARTAL P., PUJOL J., Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system, British Journal of Ophthalmology 96(9), 2012, pp. 1204–1210, DOI:10.1136/bjophthalmol-2011-301055.
  • [21] PAZ FILGUEIRA C., SÁNCHEZ R.F., ISSOLIO L.A., COLOMBO E.M., Straylight and visual quality on early nuclear and posterior subcapsular cataracts, Current Eye Research 41(9), 2016, pp. 1209–1215, DOI:10.3109/02713683.2015.1101139.
  • [22] CHRISTARAS D., GINIS H., ARTAL P., Spatial properties of fundus reflectance and red-green relative spectral sensitivity, Journal of the Optical Society of America A 32(9), 2015, pp. 1723–1728, DOI:10.1364/JOSAA.32.001723.
  • [23] Safety of Laser Products, IEC 60825-1 Standard, 2007.
  • [24] DÍAZ-DOUTÓN F., BENITO A., PUJOL J., ARJONA M., GÜELL J.L., ARTAL P., Comparison of the retinal image quality with a Hartmann–Shack wavefront sensor and a double-pass instrument, Investigative Ophthalmology and Visual Science 47(4), 2006, pp. 1710–1716, DOI:10.1167/iovs.05-1049.
  • [25] HOFER H., ARTAL P., SINGER B., ARAGÓN J.L., WILLIAMS D.R., Dynamics of the eye’s wave aberration, Journal of the Optical Society of America A 18(3), 2001, pp. 497–506, DOI:10.1364/JOSAA.18.000497.
  • [26] BARRIONUEVO P.A., COLOMBO E.M., VILASECA M., PUJOL J., ISSOLIO L.A., Comparison between an objective and a psychophysical method for the evaluation of intraocular light scattering, Journal of the Optical Society of America A 29(7), 2012, pp. 1293–1299, DOI:10.1364/JOSAA.29.001293.
  • [27] DE WIT G.C., FRANSSEN L., COPPENS J.E., VANDEN BERG T.J., Simulating the straylight effects of cataracts, Journal of Cataract and Refractive Surgery 32(2), 2006, pp. 294–300, DOI:10.1016/j.jcrs.2006.01.048.
  • [28] LOGEAN E., DALIMIER E., DAINTY C., Measured double-pass intensity point-spread function after adaptive optics correction of ocular aberrations, Optics Express 16(22), 2008, pp. 17348–17357, DOI:10.1364/OE.16.017348.
  • [29] ZHAO J., XIAO F., KANG J., ZHAO H., DAI Y., ZHANG Y., Quantifying intraocular scatter with near diffraction-limited double-pass point spread function, Biomedical Optics Express 7(11), 2016, pp. 4595–4604, DOI:10.1364/BOE.7.004595.
  • [30] MARTÍNEZ-RODA J.A., VILASECA M., ONDATEGUI J.C., GINER A., BURGOS F.J., CARDONA G., PUJOL J., Optical quality and intraocular scattering in a healthy young population, Clinical and Experimental Optometry 94(2), 2011, pp. 223–229, DOI:10.1111/j.1444-0938.2010.00535.x.
  • [31] BERENDSCHOT T.T., DELINT P.J., VAN NORREN D., Fundus reflectance—historical and present ideas, Progress in Retinal and Eye Research 22(2), 2003, pp. 171–200, DOI:10.1016/S1350-9462(02)00060-5.
  • [32] GINIS H., PÉREZ G.M., BUENO J.M., ARTAL P., The wide-angle point spread function of the human eye reconstructed by a new optical method, Journal of Vision 12(3), 2012, article 20, DOI:10.1167/12.3.20.
  • [33] CAO D., NICANDRO N., BARRIONUEVO P.A., A five-primary photostimulator suitable for studying intrinsically photosensitive retinal ganglion cell functions in humans, Journal of Vision 15(1), 2015, article 27, DOI:10.1167/15.1.27.[
  • [34] BARRIONUEVO P.A., CAO D., Luminance and chromatic signals interact differently with melanopsin activation to control the pupil light response, Journal of Vision 16(11), 2016, article 29, DOI:10.1167/16.11.29.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2021).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-945bc14d-c2de-46e2-8e85-61ebe4e3cc0a
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.