PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

COD fractions in raw and mechanically treated wastewater

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Frakcje ChZT w ściekach surowych i mechanicznie oczyszczonych
Języki publikacji
EN
Abstrakty
EN
The paper presents results of studies concerning the designation of COD fraction in the raw and mechanically treated wastewater in different year seasons. The research object was a mechanical-biological wastewater treatment plant with the output of >40 000 P.E., located in western Poland. The results of COD fraction in the raw wastewater were compared with data received in the ASM models. Methodology for determining the COD fraction was based on the guidelines ATV - A 131. During the research following fractions were determined: particulate slowly biodegradable substrates (Xs), soluble readily biodegradable substrates (Ss), inert particulate organic material (Xr) and inert soluble organic material (Sr). Soluble and particulate components were differentiated by filtration through 0.45μm membrane filters. The percentage of each fraction in total COD determined on the real concentration in raw wastewater are different from data reported in the literature.
PL
W artykule przedstawiono wyniki badań dotyczące frakcji ChZT w ściekach surowych i mechanicznie oczyszczonych w piaskowniku. Badania prowadzono w mechaniczno-biologicznej oczyszczalni ścieków o wielkości>40 000 RLM, zlokalizowanej w zachodniej Polsce. Próbki do badań pobierano w różnych porach roku. Metodyka wyznaczania frakcji ChZT została opracowana w oparciu o wytyczne ATV-131. Podczas badań określono następujące frakcje: substancje organiczne w zawiesinie, biologicznie wolno rozkładalne (Xs), rozpuszczone substancje organiczne, biologicznie łatwo rozkładalne, (Ss), substancje organiczne w zawiesinie, biologicznie trudno rozkładalne (Xr) i rozpuszczone substancje organiczne, biologicznie nierozkładalne (Sr). Rozdziału frakcji rozpuszczonych i w zawiesinie dokonano przez filtrację próbek ścieków przez filtry membranowe o wielkości porów 0,45 μm. Wyniki badań wykazały, że zarówno w ściekach surowych jak i oczyszczonych mechanicznie udział frakcji biodegradowalnych wynosił ok. 80% całkowitego ChZT. Oczyszczanie ścieków w piaskowniku spowodowało obniżenie stężenia zanieczyszczeń organicznych o ok. 30% oraz wpływało na zmiany w udziale frakcji rozpuszczonych i w zawiesinie. Wartości procentowego udziału frakcji XS i XI w ściekach po piaskowniku zmalały, podczas gdy wartości procentowego udziału frakcji Ss i Sr wzrosły, w stosunku do ich udziału w ściekach surowych. Udział procentowy frakcji ChZT w ściekach surowych wyznaczony w badaniach różni się od danych zawartych w modelach ASM1 i ASM 2.
Rocznik
Tom
Strony
101--113
Opis fizyczny
Bibliogr. 26 poz., rys., tab.
Twórcy
  • University of Zielona Góra, Institute of Environmental Engineering
autor
  • University of Zielona Góra, Institute of Environmental Engineering
autor
  • University of Zielona Góra, Institute of Environmental Engineering
Bibliografia
  • 1. Brdjanovic D., Van Loosdrecht M.C.M., Versteeg P., Hooijmans Ch.M., Alaerts G.J., Heijnen J.J.: Modeling COD, N and P removal in a full-scale WWTP Haarlem Waarderpolder. Water Research 34, 3(2000),846-858.
  • 2. Brun R., Kühni M., Siegrist H., Gujer W., Reichert P.: Practical identifiability of ASM2d parameters-systematic selection and tuning of parameter subsets, Water Research 36, (2002),113-4127.
  • 3. Dulekgurgen E., Dogruel S., Karahan Ö., Orhon D.: Size distribution of wastewater COD fractions as an index for biodegradability, Water Research 40, (2006), 273-282.
  • 4. Ekama G.A., Dold P.,L., Marais G.v.R.: Procedures for determining influent COD. Fractions and the maximum species growth rate of heterotrophs in activated sludge systems, Wat.Sci.Tech. 18, (1986),94-114.
  • 5. Gernaey K.V., Van Loosdrecht M.C.M., Henze M., Lind M., Jorgensen S.B.: Activated sludge wastewater treatment plant modelling and simulation: state of art, Environmental Modelling&Software 19, (2004),763-783.
  • 6. Gujer W., Henze M., Mino T., Matsuo T., Wentzel M.C., Marais G.v.R.: The activated sludge model no.2: Biological phosphorus removal, Wat. Sci. Tech. 31, 2(1995),1-11.
  • 7. Gujer W., Henze M., Mino T., Van Loosdrecht M.: Activated sludge model No.3, Wat. Sci. Tech. 39, 1(1999), 183-193.
  • 8. Henze M., Grujer W., Mino T., Matsuo T., Wentzel M.C., Marais Gv.R., Van Loosdrecht M.C.M.: Activated Sludge Model No.2D ASM2D, Water Science and Technology 39,1(1999),165-182.
  • 9. Henze M., Gujer W., Mino T., Matsuo T., Wentzel M.C., Marais G.v.R: Wastewater and biomass characterization for the activated sludge model no.2: Biological phosphorus removal, Wat. Sci. Tech. 31,2(1995), 13-23.
  • 10. Henze M., Gujer W., Mino T., Van Loosdrecht M.: Activated sludge models ASM1, ASM2, ASM2d, ASM3. Iwa Task Group On Mathematical Modelling For Design And Operation Of Biological Wastewater Treatment, London, 2007.
  • 11. Hu Z., Chandran K., Smets B.F., Grasso D.: Evaluation of rapid physical-chemical method for the determination of extant soluble COD, Water Research 36, (2002),617-624.
  • 12. Karahan Ö., Dogruel S., Dulekgurgen E., Ohron D.: COD fraction of tannery wastewaters tannery wastewaters - Particle size distribution, biodegradability and modeling, Water Research 42, (2008), 1083-1092.
  • 13. Lagarde F., Tusseau-Vuillemin M-H., Lessard P., Héduit A., Dutrop F., Mouchel J-M.: Variability estimation of urban wastewater biodegradable fractions by respirometry, Water Research 39, (2005), 4768-4778.
  • 14. Mąkinia J.,Wells S.A.: A general model of the activated sludge reactor with dispersive flow-I.model development and parameter estimation, Water Research 34, 16(2000),3987-3996.
  • 15. Melcer H., Dold P.L., Jones R.M., Bye Ch.M., Takacs I., Stensel H.D., Wilson A.W., Sun P., Bury S.: Treatment Processes and Systems. Methods for Wastewater Characterization in Activated Sludge Modeling, Water Environment Research Foundation, 2003.
  • 16. Myszograj S.: Charakterystyka frakcji ChZT w procesach mechaniczno-biologicznego oczyszczania ścieków. II Kongres Inżynierii Środowiska, Monografie Komitetu Inżynierii Środowiska PAN, 39 (2005), Lublin.
  • 17. Nopens I., Badstone D.J., Copp J. B., Jeppson U., Volcke E., Alex, Vanrollehghem P.A.: An ASM/ADM model interface for dynamic plant-wide simulation, Water Research 43,(2009),1913-1923.
  • 18. Orhon D., Ates E., Sözen S., Cokgör E.U.: Characterization and Cod fractionation of domestic wastewaters, Environmental Pollution, 95, 2(1997),191-204.
  • 19. Pasztor I., Thury P., Pulai J.: Chemical oxygen demand fractions of municipal wastewater for modeling of wastewater treatment, International Journal of Environmental Science and Technology, 6, 1 (2009), 51-56.
  • 20. Płuciennik-Koropczuk E.: Frakcje ChZT miarą skuteczności oczyszczania ścieków, Gaz, Woda i Technika Sanitarna 7-8 (2009),11-13.
  • 21. Sadecka Z., Myszograj S.: Frakcje ChZT w procesach mechaniczno-biologicznego oczyszczania ścieków na przykładzie oczyszczalni ścieków w Sulechowie, Rocznik Ochrona Środowiska, 6,(2004), 233-244.
  • 22. Sadecka Z., Płuciennik-Koropczuk E.: Frakcje ChZT ścieków w mechaniczno-biologicznej oczyszczalni, Rocznik Ochrona Środowiska, T. 13 cz.2 (2011), 1157—1172.
  • 23. Spérandio M., Etienne P.: Estimation of wastewater biodegradable COD fractions by combining respirometric experiments in various SO/XO ratios, Water Research, 34,4 (2000), 1233-1246.
  • 24. Vandekerekhove A., Moerman W., Van Hulle S.W.H.: Full-scale modeling of a food industry wastewater treatment plant in view of process upgrade, Chemical Engineering Journal 135,(2008), 185-194.
  • 25. Vanrolleghem P.A., Spanjers H., Petersen B., Ginestet P., Takacs I.: Estimating Combination of activated sludge model no.1 parameters and components by respirometry, Wat. Sci.Tech., (1999),195-214.
  • 26. Wytyczna ATV – DVWK – A 131 P.: Wymiarowanie jednostopniowych oczyszczalni ścieków z osadem czynnym. Wydawnictwo Seidel – Przywecki, 2002.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-91c132db-228f-46a4-af75-067eb96b3f92
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.