Sprawdzenie nośności na ścinanie ścian murowych zbrojonych jednocześnie poziomo i pionowo z wykorzystaniem wykresu interakcji VRd – NEd
Konferencja
9th World Multidisciplinary Congress on Civil Engineering, Architecture, and Urban Planning - WMCCAU 2024 : 2-6.09.2024
Języki publikacji
Abstrakty
This paper describes principles of verifying load capacity of masonry walls subjected to horizontal and vertical loading in accordance with EN 1996-1-1:2010 and the draft version of Eurocode 6 (prEN 1996-1-1:2017), As in the V method (where only vertical reinforcement is present) or in the H method (where only horizontal reinforcement is present), the VH method analyses simultaneously the vertical and horizontal reinforcement. The analysis included cases a, b, and c, which differed in the distribution of normal stresses at the wall edges determining the form of equations for ultimate limit states (ULS). Necessary equations for determining load capacity of a section against vertical load NEd are presented. There are also representative VRd – NEd interaction diagrams.
Czasopismo
Rocznik
Tom
Strony
art. no. 13
Opis fizyczny
Bibliogr. 5 poz., tab., wykr.
Twórcy
autor
- Laboratory of Civil Engineering Faculty and Department of Building Structures, Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland
Bibliografia
- 1. EN-1996-1-1:2010 Eurocode 6. Design of masonry structures. Part 1-1: General rules for reinforced and unreinforced masonry structures.
- 2. prEN-1996-1-1:2017 Eurocode 6. Design of masonry structures. Part 1-1: General rules for reinforced and unreinforced masonry structures. (Draft).
- 3. R. Jasiński, Verifying the Shear Load Capacity of Masonry Walls by the VRd –NEd Interaction Diagram. IOP Conf. Series: Materials Science and Engineering. IOP Conf. Series: Materials Science and Engineering 1203 (2021) 022031. https://doi:10.1088/1757-899X/1203/2/022031.
- 4. R. Jasiński, Verifying the shear load capacity of horizontally reinforced masonry walls by the VRd – NEd interaction diagram. AIP Conference Proceedings, 2023, vol. 2928, nr 1, American Institute of Physics. https://doi:10.1063/5.0170460.
- 5. R. Jasiński, Verifying the Shear Load Capacity of Vertically Reinforced Masonry Walls by the VRd–NEd Interaction Diagram. In: 8th World Multidisciplinary Civil Engineering - Architecture - Urban Planning Symposium. WMCAUS 2023. Prague 2023.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa nr POPUL/SP/0154/2024/02 w ramach programu "Społeczna odpowiedzialność nauki II" - moduł: Popularyzacja nauki i promocja sportu (2025).