Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Analiza skuteczności transmisji układów PLC wykonanych w różnych technologiach, pracujących w obszarze jednej sieci elektroenergetycznej
Języki publikacji
Abstrakty
This paper aims to present current knowledge on data transmission between smart grids elements using narrow-band Power Line Communications (PLC) technology. One of the published hypotheses suggests that narrow-band PLC technologies cannot co-occur in the same network without interference. This paper demonstrates the results of laboratory tests for transmission capacity of PLC systems that are made using PRIME and OSGP technologies and work in the same network. The methodology for the interoperability assessment of both PLC technologies is presented with regard to the transmission capacity measurements under reference conditions. On the basis of obtained results practical conclusions were formulated.
W artykule omówiono stan wiedzy na temat transmisji danych pomiędzy elementami inteligentnych sieci elektroenergetycznych (smart grids) realizowanych z użyciem technologii Power Line Communications (PLC) w wydaniu wąskopasmowym. Jedną z hipotez wynikłych z przeglądu literaturowego zagadnienia zawiera domniemanie, że różne wąskopasmowe technologie PLC nie mogą współistnieć w tym samym obwodzie sieci energetycznej, gdyż mogą się wzajemnie zakłócać. W artykule przedstawiono wyniki laboratoryjnych badań efektywności transmisji układów PLC, wykonanych w technologiach PRIME oraz OSGP, pracujących w tym samym obwodzie sieci energetycznej. Przedstawiono metodologię oceny interoperacyjności obu technologii PLC w odniesieniu do pomiarów skuteczności transmisji w warunkach referencyjnych. Na podstawie uzyskanych wyników badań sformułowano odpowiednie wnioski praktyczne.
Wydawca
Czasopismo
Rocznik
Tom
Strony
130--134
Opis fizyczny
Bibliogr. 18 poz., rys., tab., wykr.
Twórcy
autor
- Politechnika Wrocławska, Katedra Energoelektryki, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław
autor
- Politechnika Wrocławska, Wydział Elektryczny, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław
Bibliografia
- [1] Ferreira H., Lampe L., Newbury J., Swart T., Power Line Communications: Theory and applications for narrowband and broadband communications over power lines, Willey, (2010)
- [2] EN 50065-1:2011, Signalling on low-voltage installations in the frequency range 3 kHz to 148,5 kHz – Part 1: General requirements, frequency bands and electromagnetic disturbances, (2011)
- [3] EN 50065-2-1:2003 + A1:2005, Signalling on low-voltage installations in the frequency range 3 kHz to 148,5 kHz – Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments, (2003)
- [4] Rönnberg S., Emission and Interaction from domestic installations in the low voltage electricity network, up to 150 kHz, PhD thesis, Luleĺ University of Technology, Luleĺ, Sweden, (2013)
- [5] Pakonen P., Siddiqui V., Electromagnetic compatibility between electronic loads and automated meter reading systems using PLC, 22nd International Conference on Electricity Distribution CIRED, Stockholm, Sweden, (2013)
- [6] Directive 2009/73/Ec of The European Parliament and of The Council of 13 July 2009, (2009)
- [7] Directive 2012/27/Eu of The European Parliament and of The Council of 25 October 2012 (2012)
- [8] Commission Staff Working Document “Country fiches for electricity smart metering Accompanying the document Report from the Commission Benchmarking smart metering deployment in the EU-27 with a focus on electricity” SWD/2014/0188 final, (2014)
- [9] Commission Staff Working Document “Cost-benefit analyses & state of play of smart metering deployment in the EU-27 Accompanying the document Report from the Commission Benchmarking smart metering deployment in the EU-27 with a focus on electricity” SWD/2014/0189 final, (2014)
- [10] Carcelle X., Power Line Communications in practice, ARTECH HOUSE, Boston-London, (2006)
- [11] Sabolić D., Varda V., Bažant A., PLC Signal Propagation Modeling, International Conference Power and Energy Systems, Rhodes, Greece, (2004)
- [12] Yoon S.-G., Jang S., Kim Y.-H., Bahk S., Opportunistic routing for smart grid with power line communication access networks, IEEE Trans. Smart Grid, (2014) no. 5 (1), 303–311
- [13] Peres P. L. D., C.R. de Souza. and Bonatti I. S., “ABCD matrix: a unique tool for linear two-wire transmission line modeling”, International Journal of Electrical Engineering Education, (2003) no. 40/3, 220-229
- [14] Meng H., Chen S., Guan Y. L., Law C. L., So P. L., Gunawan E., Lie T.T., Modeling of transfer characteristics for the broadband power line communication channel, IEEE Transactions on Power Delivery, (2004), vol. 19, 1057-1064
- [15] Kiedrowski P., Measurement method of the LV network for the PLC PRIME transmission and its application, Przegląd Elektrotechniczny, (2015), no 4, 99-103
- [16] Pyda D., Habrych M., Rutecki K., Miedzinski B., Analysis of narrow band PLC technology performance in low-voltage network, Elektronika i Elektrotechnika, (2014), no. 5, 61-64
- [17] Mlynek P., Misurec J. and Koutny M., Modeling and evaluation of power line for Smart grid communication, Przegląd Elektrotechniczny, 87 (2011), nr.8, 228-232
- [18] Xiao Y., Zhang J., Pan F., et al. Power Line Communication simulation considering cyclostationary noise for metering systems, Journal of Circuits Systems and Computers, (2016) no. 9, article number: 1650105
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-8cb10868-ddb1-45a7-a052-af98da451c0f