PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Escherichia coli in sewage sludge - detection method

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Escherichia coli w osadach ściekowych - metoda wykrywania
Języki publikacji
EN
Abstrakty
EN
Escherichia coli is Gram-negative optionally anaerobic roads which belongs to Enterobacteriaceae family. Includes in a physiological bacterial flora of human and warm-blooded animals large intestine. Escherichia coli is being met in abiotic elements of the environment so as waters, wastewater, sewage sludge, soil and the food. This bacterium is showing the pathogenicity in named terms for the peoples, triggering diseases mainly: gastrointestinal tract and urinary. Quality and quantitative proposed detections method of the bacteria E. coli contains five/six steps: - appointment dry suspended solid, - preparation averaged, test of sample and resuscitation of bacteria, - making dilutions, - enrichment and differentiation in chromogenic-selective medium, - enumerating the amount of cfu E. coli in 1 g of a dry weight, - optionally, the biochemical identification.
PL
Escherichia coli jest Gram-negatywną, względnie beztlenową pałeczką należącą do rodziny Enterobacteriaceae. Wchodzi w skład fizjologicznej flory bakteryjnej jelita grubego człowieka oraz zwierząt stałocieplnych. Spotyka się ją w elementach abiotycznych środowiska, takich jak wody, ścieki, osady ściekowe, gleba i żywność. Bakteria ta w określonych warunkach wykazuje chorobotwórczość dla człowieka, wywołując głównie schorzenia układów pokarmowego i moczowego. Proponowana metoda jakościowa i ilościowa wykrywania bakterii E. coli zawiera pięć/sześć etapów: - oznaczenie suchej masy osadu, - przygotowanie próbki uśrednionej i badawczej oraz przywrócenie bakteriom aktywności fizjologicznej, - wykonanie rozcieńczeń, - namnażanie i identyfikacja na podłożu chromogennym-selektywnym, - wyliczenie ilości jtk E. coli w 1 g suchej masy osadu, - opcjonalnie identyfikacja biochemiczna.
Rocznik
Strony
79--85
Opis fizyczny
Bibliogr. 22 poz.
Twórcy
autor
  • Institute of Engineering and Environmental Protection, Faculty of Materials and Environmental Sciences, University of Bielsko-Biala, ul. Willowa 2, 43-309 Bielsko-Biała, Poland
Bibliografia
  • [1] Kocwa-Haluch R, Woźniakiewicz T. Czasopismo Techn. 2011;6:141-162.
  • [2] Albert M, Biziagos E, Crance JM, Deloince R, Schwartzbrod L. J Fr Hydrol. 1990;2:275-283.
  • [3] Chapron CD, Ballester NA, Margolin AB. J Appl Microbiol. 2000;89:11-15. DOI: 10.1046/j.1365-2672.2000.01067.x
  • [4] Gantzer C, Gaspard P, Galvez L, Huyard A, Dumouthier N, Schwartzbrod J. Water Res. 2001;35:3763-3770. DOI: 10.1016/S0043-1354(01)00105-1.
  • [5] Barbier D, Ferrine D, Duhamel C, Doublet R, Georges P. Appl Environ Microbiol. 1990;56:1420-1422.
  • [6] Jabłoński L. Podstawy mikrobiologii lekarskiej. Warszawa: PZWL; 1986.
  • [7] Zaremba M., Borowski J. Mikrobiologia lekarska. Warszawa: PZWL; 2013.
  • [8] Holt JG, Krieg NR, Sneath PHA, Staley JT, Williams ST. Bergeys Manual of Determinative Bacteriology, 9th ed. New York: Lippincott Williams and Wilkins A Wolters Company; 2004.
  • [9] Bitton G. Wastewater Microbiology. New York: Willey-Liss; 2005.
  • [10] Virella G. Mikrobiologia i choroby zakaźne. Wrocław: Urban & Palmer; 2000.
  • [11] Rozporządzenia Ministra Środowiska z dnia 13 lipca 2010 r. w sprawie komunalnych osadów ściekowych (DzU 2010, Nr 137, poz. 924).
  • [12] Reinthaler FF, Posch J, Feierl G, Wust D, Haas D, Ruckenbauuer G, et al. Water Res. 2010;37:1685-1696. DOI: 10.1016/j.watres.2009.11.052.
  • [13] Nowicka E, Machnicka A. Ocena skuteczności higienizacji osadu nadmiernego suchym lodem. In: Współczesne problemy ochrony środowiska. Gliwice: Arch Gosp Odpad Ochr Środow. 2013.
  • [14] Machnicka A, Grűbel K, Rusin A. Ecol Chem Eng S. 2012;19:415-421. DOI: 10.2478/v10216-011-0031-x.
  • [15] Fijałkowski KL, Kacprzak MJ, Rorat A. Desalin Water Treat. 2014;52:1-8. DOI: 10.1080/19443994.2014.887499.
  • [16] Herwaldt BL, Craun GF, Stokes SL, Juranek DD. J Am Water Works Assoc. 1992;84:129-135.
  • [17] Boyce TG, Swerdlow DL, Griffin PMN. Engl J Med. 1995;333:364-368.
  • [18] Zhang XX, Zhang T, Fang HH. Appl Microbiol Biotechnol. 2009;82:397-414. DOI: 10.1007/s00253-008-1829-z.
  • [19] Watkinson AJ, Micalizzi GB, Graham GM, Bates JB, Costanzo D. Appl Environ Microbiol. 2007;73:5667-5670.
  • [20] Houndt T, Ochman H. Appl Environ Microbiol. 2000;66:5406-5409. DOI: 10.1128/AEM.66.12.5406-5409.2000.
  • [21] Reinthaler FF, Posch J, Feierl G, Wust D, Haas D, Ruckenbauuer G, et al. Water Res. 2003;37:1685-1696. DOI: 10.1016/S0043-1354(02)00569-9.
  • [22] Eaton AD, Clesceri LS, Greenberg AE. Standard Methods for the Examination of Water and Wastewater, 19th ed. Washington: American Public Health Association; 1995.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-8c7f4354-39a7-4a1e-99db-796da02b2c96
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.