Koncepcja monitoringu quasi-3D procesów filtracyjno-erozyjnych w zaporach i wałach, ze szczególnym uwzględnieniem czujników liniowych
Języki publikacji
Abstrakty
The primary purpose of this article is to present the concept of quasi-spatial monitoring of seepage and erosion processes and phenomena in the area of georisk, using invasive instrumental measurement methods, including, in particular, linear or quasi-linear measurement sensors. Along with the risk of water overflow over the crest of earth damming hydraulic structures, these processes and phenomena pose the main threats for their safety and are the main causes of their repairs. The proposed solutions seem to be valuable ones and have a high application potential. Taking into account the development of measurement methods and the field of the automatic control of the condition of a structure, they will probably be used increasingly frequently in the damming hydro-engineering constructions.
W artykule skupiono się na przedstawieniu koncepcji quasi-przestrzennego monitoringu procesów filtracyjno-erozyjnych oraz zjawisk z obszaru georyzyka z zastosowaniem instrumentalnych, inwazyjnych metod pomiarowych ze szczególnym uwzględnieniem liniowych lub quasi-liniowych czujników pomiarowych. Te procesy i zjawiska, wraz z zagrożeniem przelania się wody przez koronę ziemnych obiektów piętrzących stanowią główne zagrożenia dla ich bezpieczeństwa oraz stanowią podstawowe przyczyny ich remontów. Zaproponowane rozwiązania wydają się cenne i mają duży potencjał aplikacyjny. Biorąc po uwagę rozwój metod pomiarowych oraz dziedziny automatycznej kontroli stanu konstrukcji prawdopodobnie będą stosowane coraz częściej w budownictwie hydrotechnicznym.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
129--139
Opis fizyczny
Bibliogr. 14 poz., il., wykr.
Twórcy
autor
- Institute of Water Engineering and Water Management, Faculty of Environmental Engineering, Cracow University of Technology
Bibliografia
- [1] Artieres O., Beck Y.-L., Fry J.-J., Guidoux C., Pinettes P., Monitoring of earthdams leaks and stability with fibre optics monitoring solution for canal dykes, Proc. of 8th ICOLD European Club Dam Symposium, Innsbruck, Austria, September 22–23, 2010, 423–437.
- [2] Beck Y.L., Cunat P., Guidoux C., Artieres O., Mars J., Fry J.J., Thermal monitoring of embankment dams by fiber optics, Proc. of 8th ICOLD European Club Dam Symposium, Innsbruck, Austria, September 22–23, 2010, 461–465.
- [3] Fauchard C., Meriaux P., Geophysical and geotechnical methods for diagnosing flood protection dikes. Guide for implementation and interpretation, Cemagref-Edition, Paris 2007, 124.
- [4] Flood PRoBe, Rapid and cost-effective dike condition assessment methods: geophysics and remote sensing, Report Number: WP3-01-12-20, 2013, 136.
- [5] Fry J.J., How to Prevent Embankments from Internal Erosion Failure?, Proc. of International symposium on dams for a changing world, 5 june, Kyoto 2012, 6.
- [6] ICOLD, Internal erosion of existing dams, levees and dikes, and their foundations, Bulletin no. 164, Volume 1, Internal erosion processes and engineering assessment, 2013.
- [7] Radzicki K., Badania filtracji w ziemnych budowlach piętrzących metodami termodetekcji, Gospodarka Wodna No. 5, 2005, 372–376.
- [8] Radzicki K., Analyse retard des mesures de températures dans les digues avec application à la détection de fuites (Zastosowanie analizy odpowiedzi opóźnionej w pomiarach temperatury ziemnych obiektów hydrotechnicznych do identyfikacji przecieków), Ph.D thesis, AgroParisTech, Paris 2009, 198.
- [9] Radzicki K., K. Bonelli S., Thermical seepage monitoring in the earth dams with Impulse Response Function Analysis model, 8h ICOLD European Club Symposium, 22–25 september, Innsbruck 2010, 649–654.
- [10] Radzicki K., Bonelli S., A possibility to identify piping erosion in earth hydraulic works using thermal monitoring, Proc. of 8h ICOLD European Club Symposium, 22–25 September, Austria 2010, 618–623.
- [11] Radzicki K., Bonelli S., Monitoring of the suffusion process development using thermal analysis performed with IRFTA model, Proc. of 6th ICSE, 2012, 593–600.
- [12] Radzicki K., The important issues of levees monitoring with special attention to thermal monitoring method application, Proc. of South Baltic Conference on New Technologies and Recent Developments in Flood Protection, 5–6 June, Gdańsk 2014, 11.
- [13] Radzicki K., Siudy A., Stoliński M., An innovative 3d system for thermal monitoring of seepage and erosion processes and an example of its use for upgrading the monitoring system at the Kozłowa Góra dam in Poland, Q.99-R.7, 25th Congress on Large Dam, 2015, 85–101.
- [14] Vogel L. B., Cassens C., Graupner A., Trostel A., Leakage detection systems by using distributed fiber optical temperature measurements, Proc. Of SPIE Smart Structures and Materials 2001, vol. 4328, 2001, 23–34.