Evaluating the uncertainty of the amount of thermal energy for metering systems with differential pressure flowmeters

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Szacowanie niepewności ilości energii cieplnej w układach pomiarowych z przepływomierzami zwężkowymi
Języki publikacji
EN
Abstrakty
EN
In commercial metering systems of thermal energy it is important to obtain not only the measured value of the amount of thermal energy, but also the characteristic of the uncertainty of this value. The paper presents the developed technique for evaluating the uncertainty of the measurement result of the amount of thermal energy for metering systems with differential pressure flowmeters used for metering the heat carrier flowrate. The technique uses the dependencies developed by the authors for calculating the relative standard uncertainty of the amount of thermal energy, enthalpy and flowrate of heat carrier. The equation for calculating the uncertainty of heat carrier enthalpy was developed by applying the dependencies of the technique IAPWS IF 97. The approaches proposed by the authors make it possible to develop dependencies for evaluating the uncertainty of the measurement result of the amount of thermal energy for systems of different configurations and systems with different types of flowmeters.
PL
Dla systemów komercyjnego rozliczania energii cieplnej ważne jest uzyskanie nie tylko zmierzonej ilości energii cieplnej, ale również charakterystyki niepewności tej ilości. W artykule opracowano technikę oceny niepewności wyniku pomiaru energii cieplnej dla systemów pomiarowych, w których do pomiaru przepływu nośnika ciepła stosowane są przepływomierze zwężkowe. Opracowana technika polega na wykorzystaniu opracowanych przez autorów zależności do obliczenia względnej standardowej niepewności ilości energii cieplnej, entalpii i przepływu nośnika ciepła. Zależność do obliczania niepewności entalpii nośnika ciepła opracowano przy użyciu zależności metody IAPWS IF 97. Podejścia zaproponowane przez autorów umożliwiają opracowanie zależności do szacowania niepewności zmierzonej wartości ilości energii cieplnej dla układów o różnej konfiguracji, a także układów wykorzystujących przepływomierze różnych typów.
Rocznik
Strony
57--63
Opis fizyczny
Bibliogr. 13 poz., tab.
Twórcy
autor
  • Lviv Polytechnic National University
  • Witold Pilecki State University of Małopolska, Oświęcim
autor
  • Lviv Polytechnic National University
  • Lviv Polytechnic National University
  • Lviv Polytechnic National University
Bibliografia
  • [1] Law of Ukraine on metrology and metrological activity, No.113/98 (in Ukrainian).
  • [2] Technical regulation of measuring equipment. Resolution of the Cabinet of Ministers of Ukraine No.163, 24.02.2016 (in Ukrainian).
  • [3] Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments.
  • [4] DSTU EN 1434-1:2019 Thermal energy meters. Part 1. General requirements (EN 1434-1:2015 + A1:2018, IDT) (in Ukrainian).
  • [5] DSTU GOST 8.586.5:2009 Metrology. Measurement of flowrate and amount of liquid and gas by means of standard differentia pressure devices. Part 5. Measurement procedure (in Ukrainian).
  • [6] ISO 5168:2005 Measurement of fluid flow – Procedures for the evaluation of uncertainties.
  • [7] MI 2553-99 Thermal energy and heat carrier in heat supply systems – Technique for evaluating the errors of measurement – Basic principles (in Russian).
  • [8] GOST R 8.728-2010 Evaluating the errors of measurement of thermal energy and mass of the heat carrier in water systems of the heat supply (in Russian).
  • [9] JCGM 100:2008, GUM 1995 Evaluation of measurement data – Guide to the expression of uncertainty in measurement, First edition.
  • [10] Release on the IAPWS Industrial Formulation 1997 for the thermodynamic properties of water and steam. The International Association for the Properties of Water and Steam, IAPWS Secretariat, 1997.
  • [11] MI 2412-97 Recommended Practice – Water systems of the heat supply – Equations for measuring the thermal energy and the amount of heat carrier (in Russian).
  • [12] Matiko F., Slabyk O., Lesovoy L., Matiko H.: Technique for evaluating the uncertainty of enthalpy of water and steam for thermal energy metering systems. Journal „Energy Engineering and Control Systems”, 4(2)/2018.
  • [13] EA-4/02 M:2013 Wyznaczanie niepewności pomiaru przy wzorcowaniu.