Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Wyznaczanie krętości dyfuzyjnej w próbkach betonów przy zastosowaniu metody mikrotomografii rentgenowskiej
Języki publikacji
Abstrakty
The paper presents a method of pore connectivity analysis applied to specimens of cement based composites differing in water to cement ratio. The method employed X-ray microtomography (micro-CT). Microtomography supplied digitized three-dimensional radiographs of small concrete specimens. The data derived from the radiographs were applied as an input into the application based on the algorithm called ‘random walk simulation’. As the result a parameter called diffusive tortuosity was established and compared with estimated porosity of examined specimens.
Artykuł prezentuje metodę wyznaczania parametru charakteryzującego intensywność połączeń mikroporów w zastosowaniu do próbek kompozytów z matrycą cementową, różniących się stosunkiem wodnocementowym. Metoda bazuje na wynikach badań z zastosowaniem mikrotomografii rentgenowskiej. Analizowano zdigitizowane zestawy danych, opisujące trójwymiarową reprezentację mikrostruktury niewielkich próbek wykonanych z betonu. Przygotowane w ten sposób skany mikrostruktury zastosowano jako dane wejściowe wprowadzone do oprogramowania wykorzystujacego algorytm ‘przypadkowo migrujących cząstek wirtualnych’. W ten sposób wyznaczono parametr mikrostruktury znany jako krętość dyfuzyjna. Parametr ten porównano z porowatością obserwowaną wyznaczoną dla zbadanych próbek przy wykorzystaniu analizy jasności voxeli w analizowanych próbkach.
Wydawca
Czasopismo
Rocznik
Tom
Strony
1115--1119
Opis fizyczny
Bibliogr. 8 poz., rys., tab., wykr.
Twórcy
autor
- Institute of Fundamental Technological Research, Polish Academy of Sciences, 5b, Pawińskiego Str., 02-106 Warszawa, Poland
autor
- Institute of Fundamental Technological Research, Polish Academy of Sciences, 5b, Pawińskiego Str., 02-106 Warszawa, Poland
autor
- Institute of Fundamental Technological Research, Polish Academy of Sciences, 5b, Pawińskiego Str., 02-106 Warszawa, Poland
autor
- Institute of Fundamental Technological Research, Polish Academy of Sciences, 5b, Pawińskiego Str., 02-106 Warszawa, Poland
autor
- Institute of Materials and Machine Mechanics, Racianska 75, 831-02 Bratislava, Słovakia
autor
- Institute of Materials and Machine Mechanics, Racianska 75, 831-02 Bratislava, Słovakia
Bibliografia
- [1] E. Landis, E. Nagy, D. Keane, S.P. Shah, Observations of internal crack growth in mortar using X-ray microtomography, Proc. of the Fourth Materials Engineering Conf. Washington, D.C., ASCE, New York (1996).
- [2] Z. Ranachowski, D. Jóźwiak-Niedźwiedzka et al., Application of X-ray microtomography and optical microscopy to determine the microstructure of concrete penetrated by carbon dioxide, Archives of Metallurgy and Materials, 59,4, (2014) DOI: 10.2478/amm-2014-0245, 1451-1457.
- [3] E.J. Garboczi, Three-dimensional mathematical analysis of particle shape using X-ray tomography and spherical harmonics: Application to aggregates used in concrete, Cement & Concrete Research 32, 1621-1638 (2002).
- [4] M. Lanzon, V. Cnudde, T. de Kock, J. Dewanckele, X-ray microtomography (μ-CT) to evaluate microstructure of mortars containing low density additions, Cement & Concrete Composites 34, 993-1000 (2012).
- [5] S.R. Stock, N.K. Naik, A.P. Wilkinson, K.E. Kurtis, X-ray microtomography (micro-CT) of the progression of sulfate attack of cement paste, Cement & Concrete Research 32, 1673-1675 (2001).
- [6] Y. Nakashima, S. Kamia, Mathematica Programs for the Analysis of Three-Dimensional Pore Connectivity and Anisotropic Tortuosity of Porous Rocks using X-ray Computed Tomography Image data, J. of Nuclear Science and Technology 44, 9, 1233-1247 (2012).
- [7] J.L.Provis, R.J. Myers, C.E. White, X-ray microtomography shows pore structure and tortuosity in alkali-activated binders, Cement & Concrete Research 42, 855-864 (2012).
- [8] E. Gallucci, K. Scrivener, A. Groso, M. Stampanoni, G. Margaritondo, Experimental investigation of the microstructure of cement pastes using synchrotron X-ray microtomography (uCT), Cement & Concrete Research 37, 360-368 (2007).
Uwagi
EN
The results presented in the paper have been obtained within the Joint Project of Polish and Slovak Academies of Sciences no. 10 entitled ‘Investigation of novel concrete compositions with application of X-ray microtomography’
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-8ac1ed49-c0ed-421f-9f51-eb473b78ab14