Tytuł artykułu
Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The paper presents the principles of exergy analysis of an air heating system. The exergy analysis allows a determination and quantitative description of the degree of irreversibility of real thermodynamic processes. It can be used as a decision-aiding tool in the selection of passive house ventilation and space heating systems. The presented method has been used for a case study calculation - an air heating system for a single room of a passive house.
Słowa kluczowe
Rocznik
Tom
Strony
105--116
Opis fizyczny
Bibliogr. 7 poz., rys., tab.
Twórcy
autor
- Institute of Environmental Engineering, Poznań Univeristy of Technology
autor
- Institute of Environmental Engineering, Poznań Univeristy of Technology
Bibliografia
- 1. Badescu V., Sicre B.: Renewable energy for passive house heating Part I. Building description, Energy and Buildings (35) 2003, pp. 1077-1084.
- 2. Balaras C.A., Drousta K., Argiriou A.A., Asimakopoulos D.N.: Potential for energy conservation in apartment buildings, Energy and Buildings (31) 2000, pp. 143-154.
- 3. Szargut J., Petela R., Exergy. PWN Warszawa, 1965 (in polish).
- 4. Bes T., Exergy in heating, air conditioning and drying processes, Industrial Energy, (11) 1962, pp. 388-392 (in polish).
- 5. Szargut J., Sequence method of determination of partial exergy losses in thermal systems, Exergy, an International Journal, 1 (2) 2001, pp. 85-90.
- 6. Wang S.P. et all, A phenomenological equation of exergy transfer and its application, Energy, (30) 2005, pp. 8.
- 7. Basińska M., Krzyżaniak G., Integrated heating-cooling system with gound heat exchanger. Conception of experimental setup; Chłodnictwo Vol. XLIII (11) 2008 (in polish).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-8aa02f61-1c57-4f71-8e7b-3d11e5055155