Thermal comfort measurements in the Energis building

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Badania komfortu cieplnego w budynku Energis
Języki publikacji
EN
Abstrakty
EN
In the paper the measurements of thermal comfort in the modern smart building “Energis” have been presented together with their analysis. The data have been obtained in the spring and the analyses of indoor air parameters as well as subjective responses of the volunteers have been conducted. Based on the performed studies it has been concluded that the people felt fine in the considered room (pleasantly warm, cool and comfortable) and described their feelings as acceptable and comfortable.
PL
W artykule przedstawiono wyniki badań i analizę komfortu cieplnego w budynku inteligentnym „Energis”. Dane eksperymentalne uzyskano w okresie wiosennym, a analiza dotyczyła parametrów powietrza wewnętrznego, jak również subiektywnych odczuć ochotników. W oparciu o przeprowadzone badania można stwierdzić, że użytkownicy czuli się dobrze w rozpatrywanym pomieszczeniu (przyjemnie ciepło i chłodno, a także komfortowo) i ocenili swoje odczucia jako akceptowalne i komfortowe.
Rocznik
Strony
10--15
Opis fizyczny
Bibliogr. 13 poz., fot., rys., wykr.
Twórcy
  • Kielce University of Technology, Poland
autor
  • İstanbul Üniversitesi-Cerrahpaşa, Turkey
Bibliografia
  • [1] Regulation of the Minister of Infrastructure, 12 April 2002, on technical conditions to be met by buildings and their location (Dz.U. [Journal of Laws] from 2002 No. 75, item 690, as amended), § 134.1.
  • [2] PN-EN ISO 6946:2008 Building components and building elements. Thermal resistance and the coefficient of thermal transmittance. Calculation method.
  • [3] Regulation of the Minister of Labour and Social Policy Dz.U. [Journal of Laws] No. 79 from 1998 concerning the highest permissible concentrations of harmful for health in the working environment.
  • [4] Directive 2002/91/EC of European Parliament and the Council of 16 December 2002 on the Energy Performance of the Buildings.
  • [5] ASHRAE Standard Ventilation for acceptable Indoor Air Quality, 1989.
  • [6] PN-EN 12599 Ventilation of buildings. Test procedures and measurement methods for the acceptance of ventilation and air conditioning systems.
  • [7] PN-78/B-03421 Ventilation and air conditioning. Calculation parameters of indoor air in rooms intended for permanent human presence.
  • [8] Suś M., Premeco, published on 2015-09-04, https://premeco.oferteo.pl/analiza-stezenia-ditlenku-wegla-w-pomieszczeniu-biurowym/artykul/1093.
  • [9] PN-EN ISO 7730:2006 Ergonomics of the thermal environment. Analytical determination and interpretation of thermal comfort using the calculation of PMV and PPD and local thermal comfort criteria.
  • [10] PN-EN 15251:2007 Indoor environmental criteria including thermal conditions, indoor air quality, lighting and noise.
  • [11] PN-EN ISO 7726:2002 Ergonomics of the thermal environment. Instruments for measuring physical quantities.
  • [12] PN-EN 12 464-1: 2004 Operational illuminance.
  • [13] Holubčík M., Klačková I., Ďurčanský P., Pyrolysis conversion of polymer wastes to noble fuels in conditions of the Slovak Republic, “Energies” 2020, 13(18), 4849.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2024).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-8a1516d6-19f3-40ea-83d9-937f29fe52bf
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.