Evaluation of radiographers’ and CT technologists’ knowledge regarding CT exposure parameters

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Introduction: Since the CT operators play an important role in the diagnosis and treatment of diseases and exposing the patients to radiation exposure, they must be aware of all CT parameters which affect the image quality and patient dose and update their knowledge in parallel with the progresses in CT technology. Therefore, the knowledge of radiographers and CT technologists regarding the CT parameters was assessed in this study to identify and resolve any potential deficiencies. Material and methods: This study was conducted in 2018 among 113 radiographers and 103 CT technologists in Khuzestan province using a three-part questionnaire containing demographic characteristics, general opinion on CT scan dose and questions assessing technologists’ knowledge of CT exposure parameters. Data were analyzed using SPSS software. Results: Total knowledge scores of radiographers and CT technologists about CT exposure parameters were 36 and 42, respectively. The highest knowledge score among technologist was the knowledge of changing parameters based on patient characteristics and the lowest was in the field of awareness of noise index and diagnostic reference levels. Conclusion: Total knowledge scores of radiographers and CT technologists about different scan parameters affecting dose and image quality was very low. Reviewing and updating the content of academic education and holding retraining courses are suggested.
Rocznik
Strony
43--50
Opis fizyczny
Bibliogr. 39 poz., rys., tab.
Twórcy
  • Isfahan University of Medical Sciences, Isfahan
  • Department of Radiology Technology, Behbahan Faculty of Medical Sciences, Behbahan
  • Jundishapur University of Medical Sciences, Ahvaz
  • Oil Industries Commissioning and Operation (OICO), Assaluyeh
Bibliografia
  • [1] Pelc NJ. Recent and future directions in CT imaging. Ann Biomed Eng. 2014;42(2):260-268.
  • [2] Sources and Effects of Ionizing Radiation: United Nations Scientific Committee on the Effects of Atomic Radiation: UNSCEAR 2008 Report to the General Assembly, with Scientific Annexes. United Nations, New York. 2008.
  • [3] 2014 CT Market Report Outlook. IMV Medical Information Division. Des Plaines (IL): IMV Medical Information Division; 2014.
  • [4] CT Benchmark Report 2007. IMV Medical Information Division. Des Plaines (IL): IMV Medical Information Division; 2007.
  • [5] Bellolio MF, Bellew SD, Sangaralingham LR, et al. Access to primary care and computed tomography use in the emergency department. BMC Health Serv Res. 2018;18(1):154.
  • [6] Fuchs VR, Sox Jr HC. Physicians’ views of the relative importance of thirty medical innovations. Health Affairs. 2001;20(5):30-42.
  • [7] NCRP Report 160. Ionizing radiation exposure of the population of the United States. National Council on Radiation Protection and Measurement, Bethesda. 2009.
  • [8] Delnevo A, Tritella S, Carbonaro LA, et al. The use of bedside chest radiography at a university hospital. Data on a two-week period. Eur J Radiol. 2012;81(3):e260-e263.
  • [9] Brenner DJ, Hall EJ. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-2284.
  • [10] Valentin J. Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann ICRP. 2007;37(1):1-79.
  • [11] Ngaile JE, Msaki PK. Estimation of patient organ doses from CT examinations in Tanzania. J Appl Clin Med Phys. 2006;7(3):80-94.
  • [12] Amis ES Jr, Butler PF, Applegate KE, et al. American College of Radiology white paper on radiation dose in medicine. J Am Coll Radiol. 2007;4(5):272-284.
  • [13] Peng W, Li Z, Xia C, et al. A CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation: Phantom and patient study. Medicine. 2017;96(30):e7324.
  • [14] Karim M, Hashim S, Bradley D, et al. Assessment of knowledge and awareness among radiology personnel regarding current computed tomography technology and radiation dose. J Phys: Conf Series. 2016;694:012031.
  • [15] Foley SJ, Evanoff M, Rainford LA. A questionnaire survey reviewing radiologists’ and clinical specialist radiographers’ knowledge of CT exposure parameters. Insights Imaging. 2013;4(5):637-646.
  • [16] Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380(9840):499-505.
  • [17] Barbic D, Barbic S, Dankoff J. An exploration of Canadian emergency physicians' and residents' knowledge of computed tomography radiation dosing and risk. CJEM. 2015;17(2):131-139.
  • [18] Soye JA, Paterson A. A survey of awareness of radiation dose among health professionals in Northern Ireland. Br J Radiol. 2008;81(969):725-729.
  • [19] Krille L, Hammer GP, Merzenich H, Zeeb H. Systematic review on physician's knowledge about radiation doses and radiation risks of computed tomography. Eur J Radiol. 2010;76(1):36-41.
  • [20] Jacob K, Vivian G, Steel J. X-ray dose training: are we exposed to enough? Clin Radiol. 2004;59(10):928-934.
  • [21] Clarke J, Cranley K, Robinson J, et al. Application of draft European Commission reference levels to a regional CT dose survey. Br J Radiol. 2000;73(865):43-50.
  • [22] Hatziioannou K, Papanastassiou E, Delichas M, Bousbouras P. A contribution to the establishment of diagnostic reference levels in CT. Br J Radiol. 2003;76(908):541-545.
  • [23] McCollough C, Branham T, Herlihy V, et al. Diagnostic reference levels from the ACR CT accreditation program. J Am Coll Radiol. 2011;8(11):795-803.
  • [24] Papadimitriou D, Perris A, Manetou A, et al. A survey of 14 computed tomography scanners in Greece and 32 scanners in Italy: Examination frequencies, dose reference values, effective dose and doses to organs. Radiat Prot Dosimetry. 2003;104(1):47-53.
  • [25] Tsapaki V, Kottou S, Papadimitriou D. Application of European Commission reference dose levels in CT examinations in Crete, Greece. Br J Radiol. 2001;74(885):836-840.
  • [26] AAPM Report No. 96. The Measurement, Reporting, and Management of Radiation Dose in CT. American Association of Physicists in Medicine. 2008.
  • [27] European Commission. Diagnostic Reference Levels in Thirty-Six European Countries. Part 2/2. Radiation Protection No 180. Luxembourg: Publications Office of the European Union, 2014.
  • [28] Groves AM, Owen KE, Courtney HM, et al. 16 Detector multislice computed tomography: estimation of radiation dose. Br J Radiol. 2004;77(920):662-665.
  • [29] Lucaya J, Piqueras J, García-Peña P, et al. Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality. Am J Roentgenol. 2000;175(4):985-992.
  • [30] Mastora I, Remy-Jardin M, Suess C, et al. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation. Eur Radiol. 2001;11(4):590-596.
  • [31] Sadigh G, Khan R, Kassin MT, Applegate KE. Radiation safety knowledge and perceptions among residents: a potential improvement opportunity for graduate medical education in the United States. Acad Radiol. 2014;21(7):869-878.
  • [32] Al Mohiy H, Sim J, Seeram E, Davidson R. Differences between Saudi Arabian and Australian radiographers' knowledge and attitudes about paediatric CT doses. Radiographer. 2011;58:21-27.
  • [33] Paolicchi F, Miniati F, Bastiani L, et al. Assessment of radiation protection awareness and knowledge about radiological examination doses among Italian radiographers. Insights Imaging. 2016;7(2):233-242.
  • [34] Kalra MK, Maher MM, Toth TL, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233(3):649-657.
  • [35] Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology. 2004;230(3):619-628.
  • [36] Hsieh J. Computed tomography: principles, design, artifacts, and recent advances. Bellingham, WA: SPIE. 2009.
  • [37] Sigal-Cinqualbre AB, Hennequin R, Abada HT, et al. Low-kilovoltage multi–detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology. 2004;231(1):169-174.
  • [38] Leschka S, Stolzmann P, Schmid FT, et al. Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol. 2008;18(9):1809-1817.
  • [39] Kim MJ, Park CH, Choi SJ, et al. Multidetector computed tomography chest examinations with low-kilovoltage protocols in adults: effect on image quality and radiation dose. J Comput Assist Tomogr. 2009;33(3):416-421.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-859abe0c-031e-4327-8f9a-e7b4b85a5f87
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.