Analiza procesu absorpcji amoniaku z powietrza dla rozproszonych prądów wody generowanych dyszami spiralnymi BETE TF 6nn oraz TF 8nn
Języki publikacji
Abstrakty
The work presents the absorption rate constant of ammonia into water using a station with spiral nozzles. In the research a station was employed with a chamber measuring 1 m x 1 m x 1 m with equipment enabling the regulation of ammonia concentration and nozzle operating parameters, as well as an ammonia concentration measurement system. In the first part of the research, the spraying characteristics of selected spiral nozzles were determined at pressures of 2 bar and 3 bar. For selected nozzle operating parameters, ammonia absorption tests were carried out at various initial concentration values: 250 ppm, 500 ppm, 1000 ppm. Based on the collected results, the nozzle characteristic p(Q), the distribution of the nozzle spray intensity in the SUFER program, the ammonia concentration curve as a function of water supply time and the absorption rate constant were determined.
W artykule przedstawiono wartości stałej szybkości absorpcji amoniaku do wody przy wykorzystaniu stanowiska z dyszami spiralnymi. W badaniach wykorzystano stanowisko z komorą o wymiarach 1 m × 1 m × 1 m wraz z osprzętem pozwalającym regulować stężenie amoniaku i parametry pracy dysz oraz układem pomiarowym stężenia amoniaku. W pierwszej części badań wyznaczono charakterystyki zraszania wybranych dysz spiralnych przy ciśnieniach 2 bar i 3 bar. Dla wybranych parametrów pracy dysz przeprowadzono badania absorpcji amoniaku przy różnych wartościach początkowych stężeniach: 250 ppm, 500 ppm, 1000 ppm. Na podstawie zgromadzonych wyników wyznaczono charakterystykę dyszy p(Q), rozkład intensywności zraszania dyszy w programie SUFER, krzywą stężenia amoniaku w funkcji czasu podawania wody oraz stałą szybkości absorpcji.
Słowa kluczowe
Wydawca
Rocznik
Tom
Strony
311--322
Opis fizyczny
Bibliogr. 15 poz., rys., tab.
Twórcy
autor
- Fire University
autor
- District Headquarters of the State Fire Service in Wrocław, Fire Station 3
autor
- Fire University
autor
- Fire University
Bibliografia
- 1. Cheng, C., Tan, W., Liu, L., (2014). Numerical simulation of water curtain application for ammonia release dispersion. Journal of Loss Prevention in the Process Industries, 30, 105–112.
- 2. Cheng, C., Tan, W., Du, H., Liu, L., (2015). A modified steady-state model for evaluation of ammonia concentrations behind a water curtain. Journal of Loss Prevention in the Process Industries, 36, 120–124.
- 3. Dandrieux, A., Dusserre, G., Ollivier, J., Fournet, H., (2001). Effectiveness of water curtains to protect firemen in case of an accidental release of ammonia: comparison of the effectiveness for two different release rates of ammonia. Journal of Loss Prevention in the Process Industries, 14, 349–355.
- 4. Fernández-Seara, J., Sieres, J., Rodríguez, C., Vázquez, M., (2005). Ammonia–water absorption in vertical tubular absorbers. International Journal of Thermal Sciences, 44, 277–288.
- 5. Gałaj, J., Drzymała, T., Tabaka, D., (2016). Analiza wpływu wydajności i kąta rozpylenia na rozkład średnic kropel w strumieniu rozpylonym wytwarzanym przez prądownicę Turbo Master 52. Bezpieczeństwo i Technika Pożarnicza, Vol. 43 Issue 3, pp. 51–62.
- 6. Hua, M., Qi, M., Yue, T., Pi, X., Pan, X., Jiang, J., (2018). Experimental Research on Water Curtain Scavenging Ammonia Dispersion in Confined Space. Procedia Engineering, 211, 256–261.
- 7. Isnard, O.,Soulhac, L., Dusserre, G., (1999). Numerical simulation of ammonia dispersion around a water curtain. Journal of Loss Prevention in the Process Industries, 12, 471–477.
- 8. Majder-Łopatka, M., Węsierski, T., Wąsik, W., Binio, Ł., (2017). Wpływ ciśnienia zasilania spiralnej dyszy wirowej na kąt rozpylenia i gęstość zroszenia strumienia wody. Zeszyty Naukowe SGSP, No. 61, pp. 137–151.
- 9. Piątek, P., Gałaj, J., Wąsik, W., (2018). Analysis of Influence of the Spray Angle on Sprinkling Intensity Distribution in the Spray Stream Produced by the Selected Turbo Type Fire-Hose Nozzle. Zeszyty Naukowe SGSP, No. 68(4), 137–157.
- 10. Polanczyk, A., Salamonowicz, Z., Dmochowska, A., Jarosz, W., (2019). Przewidywanie zasięgu strefy zagrożenia dla wycieku amoniaku z przemysłowej instalacji chłodniczej. Zeszyty Naukowe SGSP. No. 69(1), 37–48.
- 11. Polanczyk, A., Salamonowicz, Z., (2018). Computational modeling of gas mixture dispersion in a dynamic setup – 2d and 3d numerical approach. E3S Web of Conferences, 44, 00146.
- 12. Salamonowicz, Z., (2018). Numerical simulation of dispersion of ammonia in industry space using the ANSYS. MATEC Web of Conferences, 247, 00044.
- 13. Ubowska, A., (2016). Amoniak w instalacjach chłodniczych przemysłu rolno-spożywczego. Bezpieczeństwo Pracy: Nauka i Praktyka, 1, 14–17.
- 14. Wąsik, W., Majder-Łopatka, M., Rogula-Kozłowska, W., (2022). Influence of Microand Macrostructure of Atomised Water Jets on Ammonia Absorption Efficiency. Sustainability, 14, 9693.
- 15. Zbrożek, P., Prasuła, J., (2009). Wpływ wielkości średnic kropli mgły wodnej na efektywność tłumienia pożarów i chłodzenie. Kwartalnik CNBOP, No. 3, pp. 113–148.